24
"POWER" AND "ABSORPTION" IN CENTRAL HEATING MODE
MAGIS HERCULES
PRO 4
Air temperature °C
d.b.
(w.b.)
-20
(-21)
-15
(-16)
-10
(-11)
-7
(-8)
-2
(-3)
2
(1)
7
(6)
10
(9)
15
(14)
20
(19)
MAGIS HERCULES
PRO 4
Air temperature °C
d.b.
(w.b.)
-20
(-21)
-15
(-16)
-10
(-11)
-7
(-8)
-2
(-3)
2
(1)
7
(6)
10
(9)
15
(14)
20
(19)
MAGIS HERCULES
PRO 4
Air temperature °C
d.b.
(w.b.)
-20
(-21)
-15
(-16)
-10
(-11)
-7
(-8)
-2
(-3)
2
(1)
7
(6)
10
(9)
15
(14)
20
(19)
- Correction factor stated DC = 0.9
- TOL = -25 °C
54
MAGIS HERCULES PRO 4-6-9
MAGIS HERCULES PRO 4
Water flow temperature °C
25
Max. output
Max. absorbed
(kW)
(kW)
3.76
1.21
4.28
1.28
4.87
1.32
4.97
1.29
4.75
1.10
4.54
0.91
4.75
0.70
5.19
0.71
5.92
0.72
6.65
0.73
Water flow temperature °C
40
Max. output
Max. absorbed
(kW)
(kW)
3.34
1.56
3.85
1.64
4.37
1.70
4.50
1.75
4.23
1.46
3.97
1.16
4.30
0.97
4.71
0.97
5.39
0.97
6.07
0.99
Water flow temperature °C
55
Max. output
Max. absorbed
(kW)
(kW)
3.81
2.08
4.05
2.10
3.66
1.75
3.36
1.53
3.90
1.32
4.15
1.37
4.77
1.38
5.39
1.40
30
Max. output
Max. absorbed
(kW)
(kW)
3.65
1.30
4.16
1.37
4.73
1.41
4.83
1.38
4.62
1.18
4.41
0.98
4.62
0.75
5.05
0.76
5.76
0.77
6.47
0.78
45
Max. output
Max. absorbed
(kW)
(kW)
3.21
1.72
3.74
1.74
4.24
1.81
4.40
1.95
4.07
1.59
3.73
1.23
4.20
1.09
4.61
1.10
5.30
1.11
5.98
1.12
60
Max. output
Max. absorbed
(kW)
(kW)
3.47
1.92
3.18
1.70
3.76
1.38
3.94
1.41
4.53
1.43
5.12
1.44
35
Max. output
Max. absorbed
(kW)
(kW)
3.48
1.46
3.96
1.54
4.51
1.59
4.60
1.55
4.40
1.33
4.20
1.10
4.40
0.85
4.81
0.85
5.48
0.87
6.16
0.88
50
Max. output
Max. absorbed
(kW)
(kW)
3.62
1.82
4.11
1.90
4.23
2.03
3.87
1.67
3.55
1.38
4.05
1.21
4.38
1.23
5.03
1.25
5.68
1.26
65
Max. output
Max. absorbed
(kW)
(kW)
3.62
1.44
3.74
1.46
4.29
1.47
4.85
1.48