Korg Volca Bass Service Manual page 12

Analogue bass machine
Hide thumbs Also See for Volca Bass:

Advertisement

Proceed to the next inspection if the inspection passed.
It change stand-by state and NG state is displayed if the inspection NG
different from the target
Please refer to the list of errors at the end of the "test mode description" about the error contents.
4-4 .Touch switch inspection
LED on the lower left touch switch is lit. Touch the left edge of the touch switch, by sliding your finger
while the touch as it is to the right edge, and release your finger across the right edge.
Upper LED of the touch position lights and lower LED the next position lights.
Proceed to the next inspection if the inspection passed.
It change stand-by state and NG state is displayed if the inspection NG
different from the target
Please refer to the list of errors at the end of the "test mode description" about the error contents.
4-5.Inspection sequential lighting touch switch LED
LED touch switch lights in order. Make sure to light in order one by one.
If you touch to the right edge, make sure that the LED of the touch switch is lit one by one in order.
(Repeat from the beginning it is lit until the end)
Proceed to the next inspection by pushing [REC] button if the inspection passed.
4-6 Inspection sequential lighting 7segLED
1 to each digit, 7-segment LED lights in the
order shown on the right figure.
After verifying the 7-segment LED on the 4-digit, and then proceed to the next test by pressing the
[FUNC] button.
5. AD and knob inspection (inspection number 3)
Operate in the order of the following description inspection target knob.
Turn the knob full right rotation and turn it full left rotation. If the knob is turned to the right edge already,
by pushing the button that is
by pushing the button that is