Whirlpool SCS3017 Owner's Manual page 14

Gas built-in cooktop
Hide thumbs Also See for SCS3017:
Table of Contents

Advertisement

Available languages

Available languages

Style 2: The cap does not have a slot and requires a wrench
to be removed.
Remove the access cap by using a wrench, turning the
access cap counterclockwise.
Remove the spring retainer from the cap by pushing against
the flat side of the spring retainer. Look at the spring retainer
to locate the "NAT" or "LP" position. Turn over the spring
retainer so the "LP" is showing on the bottom. Snap the spring
retainer back into the cap. Reinstall the cap onto the regulator.
E
A. Access cap
B. Gasket
C. Gas pressure
regulator
4. Test the gas pressure regulator and gas supply line.
The regulator must be checked at a minimum 2.5 cm water
column above the set pressure. The inlet pressure to the
regulator should be as follows for operation and checking the
regulator setting:
Propane Gas:
Minimum pressure: 10" (25.4 cm) WCP, 2.49 kPa (0.36 psi)
Supply pressure: 14" (35.56 cm) WCP, 3.5 kPa (0.50 psi)
Gas Supply Pressure Testing
Line pressure testing above 1/2 psi (3.5 kPa) gauge
14" (35.5 cm WCP)
The cooktop and its individual shut-off valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of
1/2 psi (3.5 kPa).
Line pressure testing at 1/2 psi (3.5 kPa) gauge
14" (35.5 cm WCP) or lower
The cooktop must be isolated from the gas supply piping
system by closing its individual manual shut-off valve during
any pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 psi (3.5 kPa).
14
A
B
D
C
LP position
D.
NAT position
E.
5. If they are installed, remove the burner grates.
Use the following chart to match the correct gas orifice spud
with the burner location and model being converted.
Propane Gas Orifice Spud Chart
Burner Rating
5,000 BTUs
9,100 BTUs
9,100/11,000 BTUs
11,000 BTUs
13,000 BTUs
Four Burner Models
Right
Model No.
front
SCS3017
Red
SCS3617
Red
GLT3057
Blue
KGCC706
Red
KGCC506
W3CG3014
Red
ICS333
Five Burner Models
Right
Model No.
front
GLT3657
Blue
KGCC766
Red
KGCC566
KGCV566
White
Burner Locations
B
A
A. Left front
B. Left rear
C. Center
6. Remove all burner caps and burner bases.
Color
Size
Red
0.66 mm
Yellow
0.88 mm
Brass
0.93 mm
Blue
1.00 mm
White
1.08 mm
A. Size stamp
or color
Right
Left
rear
front
Brass
Brass
Blue
Blue
Red
Blue
Blue
White
Brass
Blue
Right
Left
Center
rear
front
Red
Brass
Blue
Blue
Brass
White
Red
Brass
White
C
D
Right rear
D.
Right front
E.
A
Left
rear
Yellow
Brass
Brass
Brass
Brass
Left
rear
Red
Red
Red
E

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents