Advertisement

Quick Links

FACTORY AUTOMATION
MANUAL
RocketLinx
ICRL-U-8M12-G60

Advertisement

Table of Contents
loading

Summary of Contents for Pepperl+Fuchs RocketLinx ICRL-U-8M12-G60

  • Page 1 FACTORY AUTOMATION MANUAL RocketLinx ICRL-U-8M12-G60...
  • Page 2 ICRL-U-8M12-G60 Manual With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services of the Electrical Industry, published by the Central Association of the Electrical Industry (Zentralverband Elektrotechnik und Elektroindustrie (ZVEI) e.V.) in its most recent version as well as the supplementary clause: "Expanded reservation of proprietorship".
  • Page 3: Table Of Contents

    ICRL-U-8M12-G60 Manual Table of Contents Table of Contents 1. Safety Instructions......................5 1.1. Warning .............................. 5 1.2. General Safety Instructions ......................5 1.3. Certified Usage..........................5 1.4. Installation Site Requirements ......................5 1.5. Device Casing............................ 6 1.6. Qualification Requirements for Personnel ..................6 1.7.
  • Page 4 ICRL-U-8M12-G60 Manual Table of Contents...
  • Page 5: Safety Instructions

    Pepperl+Fuchs for return procedures. 1.3. Certified Usage Use the following guidelines: • Use the ICRL-U-8M12-G60 only for the application cases described in the Pepperl+Fuchs product information, including this manual. • Operate the product only according to the technical specifications.
  • Page 6: Device Casing

    ICRL-U-8M12-G60 Manual Safety Instructions • Use the device in an environment with a maximum pollution degree that complies with the specifications in the technical data. See Technical Data on Page 16 for more information. Note: Operation of the device in high humidity or condensing atmospheres is exclusively allowed when using recommended accessories with IP67 rating.
  • Page 7: Requirements For Connecting Electrical Wires

    • The power supply cable is suitable for the voltage, the current and the physical load. Pepperl+Fuchs recommends a wire diameter of 0.5 mm² to 0.75 mm² (AWG20 up to AWG18). The following requirements apply alternatively.
  • Page 8: Relevant For Use In Explosion Hazard Areas (Hazardous Locations, Class I, Division 2)

    ICRL-U-8M12-G60 Manual Safety Instructions Requirements for Connecting the Supply Voltage Alternative Relevant for North America: The total voltage supply complies with the requirements as per NEC Class 2. All of the following requirements are complied with: The power supply complies with the requirements for a safety extra-low voltage (SELV) as per IEC/EN 60950-1.
  • Page 9: Product Overview

    Product Overview 2. Product Overview The RocketLinx ICRL-U-8M12-G60 is an 8-port unmanaged field-mountable Ethernet switch designed for use in industrial applications. With eight 10/100 Mbps Ethernet ports and redundant power inputs all utilizing M12 connections, it achieves an IP65/67 protection rating. Its passively cooled design ensures long-term reliability while supporting a wide operating temperature range from -40 to +70 °C making it appropriate for use in...
  • Page 10: Ethernet Ports (10Base-T/100Base-Tx)

    ICRL-U-8M12-G60 Manual Product Overview 2.2. Ethernet Ports (10BASE-T/100BASE-TX) You can connect terminal devices and other segments at the ports of the ICRL-U-8M12-G60 using twisted pair cables. The Ethernet ports are 4-pin, D-coded M12 sockets. The 10/100 Mbps twisted pair port allows you to connect network components according to the IEEE 802.3 10BASE-T/100BASE-TX standard.
  • Page 11: Port Status

    Update of the green/ flashing configuration via the yellow alternately M12 interface 2.3.3. ACA Connector The ACA connector is a 5-pin, A-coded M12 socket with shielding that used by Pepperl+Fuchs during the manufacture process.
  • Page 12: Installation

    ICRL-U-8M12-G60 Manual Installation 3. Installation The ICRL-U-8M12-G60 has been developed for practical application in a harsh industrial environment. On delivery, the device is ready for operation. Perform the following steps to install the ICRL-U-8M12-G60: • Checking the package contents • Installing and grounding the device •...
  • Page 13 ICRL-U-8M12-G60 Manual Installation Install the ICRL-U-8M12-G60 accordingly. 1. Prepare the drill holes at the installation point. 2. Mount the device on a level surface with two M4 screws.
  • Page 14: Grounding The Icrl-U-8M12-G60

    The following requirements need to be met before wiring the power supply. • The power supply cable is suitable for the voltage, the current and the physical load. Pepperl+Fuchs recommends a wire diameter of 0.5 mm² to 0.75 mm² (AWG20 up to AWG18).
  • Page 15: Connecting Data Cables

    ICRL-U-8M12-G60 Manual Installation 3.4. Connecting Data Cables Use the following guidelines when connecting the data cables. • Shielded CAT5e cable or better. • SF/UTP cables as per ISO/IEC 11801:2002. • Shielded D-coded, 4-pin M12 connectors. • Keep the length of the data cables as short as possible. •...
  • Page 16: Technical Data

    ICRL-U-8M12-G60 Manual Technical Data 4. Technical Data ICRL-U-8M12-G60 General Technical Data Safety extra-low voltage (SELV) Relevant for North NEC Class 2 power source max. 2A. America: Rated voltage DC: 12/24/36V DC Voltage range DC incl. 9.6V DC ... 45V DC maximum tolerances: Power supply Connection type...
  • Page 17 Twinsburg, Ohio 44087 · USA Tel. +1 330 4253555 E-mail: sales@us.pepperl-fuchs.com Asia Pacific Headquarters Pepperl+Fuchs Pte Ltd. Company Registration No. 199003130E Singapore 139942 Tel. +65 67799091 E-mail: sales@sg.pepperl-fuchs.com www.pepperl-fuchs.com DOCT-7053 Subject to modifications Copyright PEPPERL+FUCHS • Printed in Germany 2021-02...