Hide thumbs Also See for Isodrive 900:

Advertisement

Quick Links

INSTALLATION GUIDE
Isodrive 900
www.schweigen.com.au
Revision V2 25/11/21

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Isodrive 900 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Schweigen Isodrive 900

  • Page 1 INSTALLATION GUIDE Isodrive 900 www.schweigen.com.au Revision V2 25/11/21...
  • Page 2: Welcome

    Welcome Thank you for purchasing your new Schweigen Isodrive system. To get the maximum output from this unit, please read through this guide before use and installation. This guide contains important information on the correct use and maintenance of the unit, as well as important safety notes.
  • Page 3: Table Of Contents

    Wall Installation ________________________________________________________________________________ 10 Flat Roof Installation ___________________________________________________________________________ 12 Through Wall Installation for Isodrive 900 _______________________________________________ 13 Fan Unit Shutter Assembly for Isodrive 900 (Optional) _____________________________________ 14 Twin 200mm Outlet Installation Example _______________________________________________ 15 5. Measurements Measurements for Isodrive 900 ______________________________________________________ 16 6.
  • Page 4: Your Safety

    Children should be supervised to ensure that they do not play with the appliance, it is not a toy. Do not install Isodrive motor to a non-Schweigen and/or non-silent rangehood. If you fail to do so, your warranty will be voided.
  • Page 5: Motor Features

    NOTE: Fan module and dual foil Steelflex duct are acoustically matched. Use of semi-rigid or rigid ducting will ™ result in increased noise and may void warranty. See installation instruction notes ‘Why Schweigen SteelFlex ™ Safety Duct’ . Recommended Installation Distance Isodrive 900 motor, recommended 4 to 5 metres of SteelFlex ducting and with at least two bends.
  • Page 6: Minimum Mounting Height

    Any installation problem must be reported ™ to Schweigen. Call outs relating to incorrect installation will result in a service fee direct to the customer. Schweigen takes no responsibility for problems caused by faulty installation, this may void warranty. A preferred installer list can be obtained from Schweigen website www.schweigen.com.au or by calling...
  • Page 7: Description

    17. ™ Isodrive Motor Included in the box: Isodrive 900 motor (280W x 200H mm approx.) Approx. 3 metre, 10amp cable and standard male plug Fire resistant 150mm (160mm OD ) PVC riser pipe Note: Cable cut-out at the bottom end only...
  • Page 8: Installation

    /hr. For more information on environmental noise limit and conditions please contact your local Council. We have a list of recommended installers available on the Schweigen website. Do not install the SteelFlex in a straight line and minimum of two gentle bends in the ducts is required.
  • Page 9 4. Installation 900 motor 50mm Pipe protrusion above dektite Power Cord 150mm PVC Pipe (Locking holes fan end) Dektite Fix fan module using side locking screw Fit side supports to locate pipe Strap to supports Bell-mouth Adaptor Connect to NOTE: Prevent any cord bunching by rangehood pulling cord through from plug top end NOTE: Minimum ducting length...
  • Page 10: Wall Installation

    Seal with silicone or urethane Locking screws to be fully *Optional wall mounting flange (P40113MF) is available tightened engaging in holes from Schweigen, please contact 1300 881 693. Figure 2 Wall Installation IMPORTANT For more SteelFlex ducting instructions, refer page 17.
  • Page 11 4. Installation IMPORTANT: When mounting pipe fan locking holes to be in outside end of pipe (fan end) Min 150mm long 150mm PVC pipe Locking holes at 10 and 4 o’clock Bell-mouth Adaptor SteelFlex ™ 200mm ducting Min 50mm 900 motor Cord slots at bottom (6 o’clock position) NOTE: Ensure that power cord is fed through exit slot and...
  • Page 12: Flat Roof Installation

    Ducting ducting end. Ensure that fan end locking holes remain *Optional wall mounting flange (P40113MF) is available from Schweigen, please contact 1300 881 693. Figure 4 IMPORTANT For more SteelFlex ducting instructions, refer page 17. Shutter assembly for 1600 motor is not ™...
  • Page 13: Through Wall Installation For Isodrive 900

    P1108* Minimum pipe protrusion from wall surface Wall 47mm Power cord Wall cover plate Slot in pipe at bottom (6 O’Clock) (optional part) *Optional parts are available from Schweigen, please contact 1300 881 693. Figure 5 Page 13...
  • Page 14: Fan Unit Shutter Assembly For Isodrive 900 (Optional)

    4. Installation Fan Unit Shutter Assembly for Isodrive 900 (Optional) 1. Assemble by fitting shutter assembly into fan inlet shroud moulding, ensuring that attaching screws align with holes. Alignment can be checked visually by folding in shutter flaps. 2. Fully tighten both screws and re-check fitment into holes.
  • Page 15: Twin 200Mm Outlet Installation Example

    4. Installation Twin 200mm Outlet Installation Example This is for use where one motor is to be used and there are two 200mm outlets, refer figure 11. 900 motor Ensure SteelFlex ducting ™ is fully extended and as short as possible. Use smooth flowing curves for maximum air flow.
  • Page 16: Measurements

    5. Measurements Measurements for Isodrive 900 (Not to Scale) 278mm 157mm 131mm 198mm 53mm 242mm 440mm Dektite 160mm Shutter assembly (optional) is not shown in the diagram. Page 16...
  • Page 17: Steelflex ™ Safety Duct

    Incorrect installation may reduce airflow or increase noise levels. Call outs relating to incorrect installation will result in a service fee directed to the customer. Schweigen will take no responsibility for problems caused by faulty installation. A list of preferred Schweigen installers can be obtained from the Schweigen website www.schweigen.com.au.
  • Page 18: Assembling Steelflex ™ Safety Duct

    6. SteelFlex Safety Duct ™ Assembling SteelFlex Safety Duct ™ SteelFlex safety duct must be secured to either the bell-mouth adapter ring or a 200mm mounting pipe. ™ Parts required: SteelFlex safety ducting ™ Steel ring clamp Bell-mouth adapter ring 200mm duct to 150mm riser 150mm PVC riser pipe 20mm self-drilling button head screws...
  • Page 19: Shallow Roof Space

    6. SteelFlex Safety Duct ™ Shallow Roof Space In shallow roof spaces, do not crush or kink SteelFlex ducting, as it will reduce air flow severely. 90 degree ™ curve made of PVC or galvanise can be used as a substitute for the bend, refer to figure 12. 90 degree curve PVC or galvanise curve Figure 12...
  • Page 20: Installing Steelflex ™ Safety Duct

    6. SteelFlex Safety Duct ™ Securing SteelFlex Safety Duct ™ SteelFlex safety duct must be installed with supports at maximum intervals of 1.5 metres. SteelFlex safety ™ ™ ductwork can be supported by using good quality gaffer or aluminium foil tape. Provided that it does not restrict the internal diameter of the ducting.
  • Page 21: Parts List

    7. Parts List Parts List for Isodrive 900 Page 21...
  • Page 22 7. Parts List Parts List for Isodrive 900 Number Part Description Quantity Number P40100 Terminal Block Cover P40121 Wire Insulator Cap P1061 O Ring 4¼” ID P1059 Capacitor 2μF P807 Terminal Block P40102 Fan Plate – Motor Mount P40122 900 Inlet Shroud Mount...
  • Page 23: Maintenance

    8. Maintenance Roof Restoration or Cleaning Before doing your roof restoration or cleaning, please completely cover the outside motor system and avoid all chemical contact. IMPORTANT Any damages caused by the use of chemical products are not covered by warranty. Figure 15 Avoid chemical contact to motor system Page 23...
  • Page 24: Warranty/Disclaimer

    All information supplied is to be used for general reference purposes only and is on the understanding that Schweigen Home Appliances will not be liable for any loss, liability or damage of whatever kind arising as a result of any reliance upon such information. All pictures used in the guide are for illustrative purposes only.
  • Page 25 Notes Page 25...
  • Page 26 Notes Page 26...
  • Page 27 Notes Page 27...
  • Page 28 Australia Unit 4/1-5 Lake Drive, Dingley Village, Victoria 3172. Phone 1300 881 693 Email sales@schweigen.com.au Web www.schweigen.com.au New Zealand 5 Tolich Place, Henderson, Auckland 0610. Phone 0800 200 510 Email info.parex@emerson.com Web www.parex.co.nz...

Table of Contents