  • Page 1 INSTALLATION GUIDE Isodrive 3000 www.schweigen.com.au Revision V2 25/11/21...
  • Page 2: Welcome

    Welcome Thank you for purchasing your new Schweigen Isodrive system. To get the maximum output from this unit, please read through this guide before use and installation. This guide contains important information on the correct use and maintenance of the unit, as well as important safety notes.
  • Page 3: Table Of Contents

    Recommended Installation Distance _____________________________________________________________ 5 Minimum Mounting Height ______________________________________________________________________ 6 Avoidance of Back Flow _________________________________________________________________________ 6 Safety of Children ______________________________________________________________________________ 6 Replacement of Supply Cord _____________________________________________________________________ 6 Why Schweigen SteelFlex Safety Duct __________________________________________________________ 6 ™ 3. Description Isodrive Motor _________________________________________________________________________________ 7 4.
  • Page 4: Your Safety

    Children should be supervised to ensure that they do not play with the appliance, it is not a toy. Do not install Isodrive motor to a non-Schweigen and/or non-silent rangehood. If you fail to do so, your warranty will be voided.
  • Page 5: Motor Features

    NOTE: Fan module and dual foil Steelflex duct are acoustically matched. Use of semi-rigid or rigid ducting will ™ result in increased noise and may void warranty. See installation instruction notes ‘Why Schweigen SteelFlex ™ Safety Duct’ . Recommended Installation Distance Isodrive 1600 motor, recommended 5 to 6 metres of SteelFlex ducting and with at least two bends.
  • Page 6: Minimum Mounting Height

    Any installation problem must be reported ™ to Schweigen. Call outs relating to incorrect installation will result in a service fee direct to the customer. Schweigen takes no responsibility for problems caused by faulty installation, this may void warranty. A preferred installer list can be obtained from Schweigen website www.schweigen.com.au or by calling...
  • Page 7: Description

    3. Description NOTE For more SteelFlex ducting instructions, refer page 19. ™ Isodrive Motor Included in each box: Isodrive 1600 motor (405W x 220H mm approx.) Approx. 3 metre, 10amp cable and standard male plug Fire resistant 150mm (160mm OD ) PVC riser pipe Note: Cable cut-out at the bottom end only SteelFlex...
  • Page 8: Installation

    /hr. For more information on environmental noise limit and conditions please contact your local Council. We have a list of experienced installers available on the Schweigen website. Do not install the SteelFlex in a straight line and minimum of two gentle bends in the ducts is required.
  • Page 9 4. Installation 1600 motor Weather shield attachment (only for 1600 motor) 50mm Pipe protrusion above dektite Power Cord 150mm PVC Pipe (Locking holes fan end) Dektite Fix fan module using side locking screw Fit side supports to locate pipe Strap to supports Bell-mouth Adaptor Connect to NOTE: Prevent any cord bunching by...
  • Page 10: Wall Installation

    Fitment Pipe Power cord to 240V supply Seal with silicone or urethane Locking screws to be fully *Optional wall mounting flange (P40113MF) is available tightened engaging in holes from Schweigen, please contact 1300 881 693. Figure 2 Wall Installation Page 10...
  • Page 11 4. Installation IMPORTANT: When mounting pipe fan locking holes to be in outside end of pipe (fan end) Min 150mm long 150mm PVC pipe Weather shield Locking holes at 10 and upper most 4 o’clock Bell-mouth Adaptor Locking Screw SteelFlex ™...
  • Page 12: Installation Through Wall With Back Draught Shutter

    Hanging Plate Height of hanging bracket 47mm above top of pipe 95mm Power Cord Slot in pipe at bottom (6 O’Clock) Optional wall cover plate P1108* *Optional parts are available from Schweigen, please contact 1300 881 693. Figure 7 Page 12...
  • Page 13: Flat Roof Installation

    NOTE: Cut 150mm PVC 200mm stormwater pipe to length and SteelFlex ™ reslot ducting end. Ensure that fan Ducting end locking holes remain *Optional wall mounting flange (P40113MF) is available from Schweigen, please contact 1300 881 693. Figure 4 Page 13...
  • Page 14: Fan Unit Shutter Assembly

    4. Installation Fan Unit Shutter Assembly for Isodrive 1600 1. Assemble by fitting shutter assembly into fan inlet shroud moulding, ensuring that attaching screws align with holes. Alignment can be checked visually by folding in shutter flaps. 2. Fully tighten both screws and re-check fitment into holes. 3.
  • Page 15: Twin Motor Installation

    4. Installation Twin Motor Installation (suitable for rangehoods with two 200mm outlets) Where two motors are to be used, follow the method below. Each motor should have a separate flue pipe. Refer figure 9. The two motors can be wired by an electrician. 1600 motor Z: Minimum distance between the two fans is 600mm.
  • Page 16 4. Installation Twin Motor Installation (suitable for rangehoods with one 200mm outlets) Where two motors are to be used and there is only one 200mm outlet, follow the below methods for each motor then join into the “Y” piece prior to joining ducting to the canopy / rangehood. Refer figure 10. The two motors can be wired by one of the following methods: •...
  • Page 17: Single Motor Installation Twin 200Mm Outlet

    4. Installation Single Motor Installation Twin 200mm Outlet (suitable for rangehoods with two 200mm outlets and one 1600 Isodrive motor) This is for use where one motor is to be used and there are two 200mm outlets, refer figure 11. 1600 motor Ensure SteelFlex ducting...
  • Page 18: Measurements

    5. Measurements Measurements for Isodrive 1600 (Not to Scale) 405mm 148mm 220mm 190mm 90mm 35mm 225mm 440mm Dektite 160mm Motor weight: 6kg net. Shutter assembly is not shown in the diagram. Page 18...
  • Page 19: Steelflex ™ Safety Duct

    Incorrect installation may reduce airflow or increase noise levels. Call outs relating to incorrect installation will result in a service fee directed to the customer. Schweigen will take no responsibility for problems caused by faulty installation. A list of preferred Schweigen installers can be obtained from the Schweigen website www.schweigen.com.au.
  • Page 20: Assembling Steelflex ™ Safety Duct

    6. SteelFlex Safety Duct ™ Assembling SteelFlex Safety Duct ™ SteelFlex safety duct must be secured to either the bell-mouth adapter ring or a 200mm mounting pipe. ™ Parts required: SteelFlex safety ducting ™ Steel ring clamp Bell-mouth adapter ring 200mm duct to 150mm riser 150mm PVC riser pipe 20mm self-drilling button head screws...
  • Page 21: Shallow Roof Space

    6. SteelFlex Safety Duct ™ Shallow Roof Space In shallow roof spaces, do not crush or kink SteelFlex ducting, as it will reduce air flow severely. 90 degree ™ curve made of PVC or galvanise can be used as a substitute for the bend, refer to figure 12. Use 90 degree curve PVC or galvanise curve to prevent crushing...
  • Page 22: Installing Steelflex ™ Safety Duct

    6. SteelFlex Safety Duct ™ Securing SteelFlex Safety Duct ™ SteelFlex safety duct must be installed with supports at maximum intervals of 1.5 metres. SteelFlex safety ™ ™ ductwork can be supported by using good quality gaffer or aluminium foil tape. Provided that it does not restrict the internal diameter of the ducting.
  • Page 23: Parts List

    7. Parts List Parts List for Isodrive 1600 For wall installation with no back drought system or flat roof installation. Page 23...
  • Page 24 7. Parts List Parts List for Isodrive 1600 Number Part Number Description Quantity P1120 M4X160mm Pan Head Screw P1120N M4 KEPS Nut (not shown in figure) P1114 Capacitor 3.5μF P1100 Fan Motor Mounting Bracket P1102 Fan Base Spinning P1113 Heyco Snap Bushing P40113 Base Moulding P1124...
  • Page 25: Maintenance

    8. Maintenance Roof Restoration or Cleaning Before doing your roof restoration or cleaning, please completely cover the outside motor system and avoid all chemical contact. IMPORTANT Any damages caused by the use of chemical products are not covered by warranty. Figure 15 Avoid chemical contact to motor system Page 25...
  • Page 26: Warranty/Disclaimer

    All information supplied is to be used for general reference purposes only and is on the understanding that Schweigen Home Appliances will not be liable for any loss, liability or damage of whatever kind arising as a result of any reliance upon such information. All pictures used in the guide are for illustrative purposes only.
  • Page 27 Notes Page 27...
  • Page 28 Australia Unit 4/1-5 Lake Drive, Dingley Village, Victoria 3172. Phone 1300 881 693 Email sales@schweigen.com.au Web www.schweigen.com.au New Zealand 5 Tolich Place, Henderson, Auckland 0610. Phone 0800 200 510 Email info.parex@emerson.com Web www.parex.co.nz...