Mitsubishi Electric Ecodan EHSC-VM6D-CN Installation Manual page 52

Hydrobox
Hide thumbs Also See for Ecodan EHSC-VM6D-CN:
Table of Contents

Advertisement

6
Service and Maintenance
Engineers Forms
Should settings be changed from default, please enter and record new setting in 'Field Setting' column. This will ease resetting in the future should the system use change
or the circuit board need to be replaced.
Commissioning/Field settings record sheet
Main remote controller screen
Main
Option
Setting
Heating
Compensation
Hi flow temp. set
curve
point
Lo flow temp. set
point
Adjust
Holiday
Initial settings
Language
en
°C/°F
Summer time
Temp. display
Time display
Room sensor settings for Zone1
Room RC zone select
Service menu
Thermistor adjustment
Auxiliary settings
Pump speed (Heating)
Heat source setting
Heat pump flow rate range
Operation set-
tings
23
Parameters
Heating room temp.
10°C - 30°C
Heating flow temp.
20°C - 60°C
Heating compensation curve
−9°C - + 9°C
Holiday mode
Active/Non active/Set time
Heating
On/Off/Timer
Energy monitor
Consumed electrical energy/Delivered energy
Operation mode
Heating room temp./ Heating flow temp./ Heating com-
pensation curve
Outdoor ambient temp.
−30°C - +33°C *1
Flow temp.
20°C - 60°C
Outdoor ambient temp.
−28°C - +35°C *2
Flow temp.
20°C - 60°C
Outdoor ambient temp.
−29°C - +34°C *3
Flow temp.
20°C - 60°C
Heating
Active/Non active
Heating room temp.
10°C - 30°C
Heating flow temp.
20°C - 60°C
EN/CN
°C/°F
On/Off
Room/Off
hh:mm/hh:mm AM/AM hh:mm
TH1/Main RC/"Time/Zone"
Zone1
THW1
−10°C - +10°C
THW2
−10°C - +10°C
Economy settings for
On/Off *4
pump.
Delay (3 - 60 min)
Electric heater
Space heating: On (used)/Off (not used)
(Heating)
Electric heater delay timer (5 - 180 min)
Flow sensor *5
Minimum(0 - 100L/min)
Maximum(0 - 100L/min)
Analog output
Interval (1 - 30 min)
Priority(Normal/High)
Pump speed(1 - 5)
Standard/Heater
Minimum(0 - 100L/min)
Maximum(0 - 100L/min)
Heating
Flow temp.range
Min.temp.(20 - 45°C)
operation
*6
Max.temp.(35 - 60°C)
Room temp.control
Mode(Normal/Fast)
*7
Interval(10 - 60min)
Heat pump thermo
On/Off *4
diff.adjust
Lower limit(−9 - −1°C)
Upper limit(+3 - +5°C)
Freeze stat function *8
Outdoor ambient temp. (3 - 20°C) / **
Cold weather function
On/Off *4
Outdoor ambient temp. (−30 - −10°C) *1
Floor dry up function
On/Off *4
Target temp.
Flow temp. (Increase) Temp. increase step (+1 - +10°C)
Flow temp. (De-
crease)
Summer mode
On/Off
Outdoor ambient
temp.
Judgement time
Forced heating ON (-30 - 10°C)
Default setting
20°C
45°C
0°C
On
Room temp.
−15°C
50°C
35°C
25°C
Active
15°C
35°C
CN
°C
Off
Off
hh:mm
TH1
Zone1
0°C
0°C
On
10 min
On
30 min
5 L/min
100 L/min
5 min
Normal
5
Standard
5 L/min
100 L/min
30°C
50°C
Normal
10min
On
−5°C
5°C
5°C
Off
−15°C
Off
Start&Finish (20 - 60°C)
30°C
Max. temp. (20 - 60°C)
45°C
Max. temp. period (1 - 20
5 days
days)
+5°C
Increase interval (1 - 7 days)
2 days
Temp. decrease step (−1 - −10°C)
−5°C
Decrease interval (1 - 7 days)
2 days
Off
Heating ON (4-19°C)
10°C
Heating OFF (5-20°C)
15°C
Heating ON (1-48 hours)
6 hours
Heating OFF (1-48 hours)
6 hours
5 °C
(Continued to next page.)
Field
Notes
setting