DeVilbiss MSV-512 Operation Manual
DeVilbiss MSV-512 Operation Manual

DeVilbiss MSV-512 Operation Manual

Lvmp spray gun

Advertisement

Quick Links

IMPORTANT: Read and follow all instructions and SAFETY PRECAUTIONS
before using this equipment. Retain for future reference.

SAFETY PRECAUTIONS

This manual contains important information that ALL users should know and understand BEFORE
using the equipment.
EQUIPMENT PROBLEMS. To help you recognize this information, we use the following terms to
draw your attention to certain equipment labels and portions of this manual. Pay special attention
to any label or information that is highlighted by one of these terms.:
Important information to alert you to a situation that might cause serious injury or
WARNING
loss of life if instructions are not followed.
CAUTION
Important information that tells how to prevent damage to equipment.
NOTE
Information that you should pay special attention to.
FIRE AND EXPLOSION
Solvents and coating materials can be highly flammable or combustible, especially when sprayed.
Work stations must be provided with adequate ventilation/exhaust to prevent the build-up of
flammable vapours.
Smoking and naked flames must not be allowed in the spraying or mixing areas.
Fire extinguishing equipment must be provided in the spraying and mixing areas.
Users must comply with all local and national codes of practice and insurance company requirements
governing ventilation, fire precautions, operation maintenance and housekeeping of work stations.
HALOGENATED HYDROCARBON SOLVENTS – for example 1,1,1-Trichloroethane and Methylene
Chloride can chemically react with aluminum and galvanised or zinc coated parts and cause an
explosion hazard. Read the label and data sheet of the material you intend to spray.
This equipment, as supplied, is suitable for use with Halogenated Hydrocarbons and the user must
ensure that all other equipment in the system is also suitable for use with these materials. DO NOT
SPRAY MATERIALS CONTAINING THESE SOLVENTS EXCEPT WITH EQUIPMENT
SPECIFICALLY DISIGINATED BY THE MANUFACTURER AS BEING SUITABLE FOR SUCH USE.
STATIC ELECTRICITY – is generated by fluid moving through pipes and hoses. A static spark,
capable of igniting certain solvents and coating materials, could be produced by high fluid flow rates.
To prevent the risk of fire or explosion, earth continuity to the spray equipment and object being
sprayed should be maintained.
PERSONAL PROTECTIVE EQUIPMENT
TOXIC VAPOURS – When sprayed, certain materials may be poisonous, create irritation or otherwise
be harmful to health. Always read carefully all labels and safety/performance data for the material
being sprayed and follow any recommendations. IF IN DOUBT, CONSULT THE MATERIAL
SUPPLIER.
MSV-512 LVMP SPRAY GUN
OPERATION MANUAL
This information relates to USER SAFETY and PREVENTING
SAFETY WARNING
− 1 −
SB-E-2-243-AE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MSV-512 and is the answer not in the manual?

Questions and answers

Summary of Contents for DeVilbiss MSV-512

  • Page 1 MSV-512 LVMP SPRAY GUN IMPORTANT: Read and follow all instructions and SAFETY PRECAUTIONS before using this equipment. Retain for future reference. SAFETY PRECAUTIONS This manual contains important information that ALL users should know and understand BEFORE using the equipment. EQUIPMENT PROBLEMS. To help you recognize this information, we use the following terms to draw your attention to certain equipment labels and portions of this manual.
  • Page 2 DESCRIPTION MSV-512 has been developed aiming at high transfer efficiency. The most merit of this gun is that fine atomization and high transfer efficiency can be obtained with less air consumption comparing with the existing guns.
  • Page 3 MODEL MSV-512-805-DFX Example: Basic part number Air Caps: 805 SPECIFICATION Maximum Air Pressure: 0.9Mpa (9 bar) Maximum Fluid Pressure: 1.4Mpa (14 bar) Weight: 470g Air Inlet Thread: G1/4 Fluid Inlet Thread: G3/8 (standard) G1/4 (optional) Fluid Supply: Pressure Feed Air Consumption: 278L/min.
  • Page 4 PARTS LIST CODE NO. PART NUMBER 1 804277 MSG-368 Refer to Chart 2 3 805118 SSG-8182-K5 Refer to Chart 2 5 803791 JGD-14-K5 6 803833 JGHV-450-46-50 7 803932 JGS-72-K10 8 803561 JGA-17 Refer to Chart 2 10 804342 MBD-19-K5 11 804270 MSG-16 12 805277 SST-8453-K5...
  • Page 5 Chart 2 Air Cap, Fluid Tip and Needle Combination Air Cap Part Number Code No. JGA-4046-DFX AV-1239-805 802447 JGA-4046-DFW JGA-4046-GD JGA-4046-DFX AV-1239-807 802449 JGA-4046-DFW JGA-4046-GD INSTALLATION/OPERATION NOTE: The air supplied to spray gun must be cleaned air which any water, oil and solid material removed.
  • Page 6 CAUTION: The air cap can be immersed in solvent for cleaning. If orifices are clogged, use a broom straw or toothpick to remove obstruction. Never use a steel wire or hard instrument. This will damage air cap and result in a distorted spray pattern. NOTE: Do not immerse any plastic parts in solvent for long time.
  • Page 7 SERVICE CHECK Normal spray pattern PROBLEM Will not spray. No pressure to gun. Screw (11) not properly adjusted. Improper spray pattern A, B. Material build up on the air C, D. Wrong material or material Jerky or fluttering spray Insufficient material in the tank or an obstruction in the line.
  • Page 8 ACCESSORIES PART NUMBER CODE NO. KB-555 800223 AD-404-J 800029 WR-103 800314 SSL-10 805153 42884-214-K5 806472 KK-5033-805 KK-5033-807 DESCRIPTION Pressure Cup (2 Quart) Adapter (1/4 NPS M, 3/8 NPS F) Wrench Gun Lube Cleaning Brush Kit of 5 Air Cap Test Kit Air Cap Test Kit −...