Download Print this page

Bosch DS9360 Installation Manual page 2

Tritech ceiling mount pir/microwave detector

Advertisement

Available languages

Available languages

Changes or modifications not expressly approved
by Bosch Security Systems, Inc. can void the user's
authority to operate the equipment.
UL
Perform Walk Test at least once a year.
Use only a Listed limited-power source.
The Listed control unit or a Listed burglary power
supply must provide 4 hours (32 mAh) of standby
power.
Install the unit in accordance with National
Electrical Code NFPA 70.
Adjust the microwave range control, if necessary, to
achieve maximum range.
SELV
Connect all wiring to a safety extra-low voltage (SELV) circuit only.
Ligue todas as cablagens apenas a um circuito de segurança de tensão extra baixa.
Conecte el cableado únicamente a un circuito de seguridad para voltajes muy bajos.
Alle Drähte sind ohne Ausnahme an Niederspannung anzuschließen.
Sluit alle bedrading uitsluitend aan op een circuit met een extra lage veiligheidsspanning.
Prenez soin de connecter tous les câbles à un circuit à très basse tension de sécurité (TBTS).
Collegare tutti i cavi esclusivamente a un circuito di sicurezza a bassissima tensione.
Specifications
Dimensions
3.5 in. x 5.25 in. (8.9 cm x 13.3 cm)
(HxDia)
Input
6.0 to 15.0 VDC; 8 mA standby, 60 mA in alarm with LEDs enabled. Use only an Approved
Power
Limited Power Source.
Standby
There is no internal standby battery. Standby power must be provided by an Approved
Power
Limited Power Source. Eight mAh required for each hour of standby time needed. For UL
Listed Requirements, 32 mAh standby current is required.
Alarm Relay
Silent-operating Form "C" relay. Contacts rated <100 mA, 25 VDC, 2.5W <20 Ohm closed
maximum for DC resistive loads.
Tamper
Contacts rated at 28 VDC, 125 mA maximum, <1 Ohm. To be connected to a SELV (Safety
Extra-Low Voltage) circuit only. Connect tamper circuit to a 24-hour protection circuit.
Compliance
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may
cause undesirable operation.
För svensk installationsanvisning se www.boschsecurity.se.
3 © 2021 Bosch Security Systems B.V.
-40°C to +49°C
(-40°F to +120°F )
UL Listed
installations,
the temperature
range is 0°C to +49°C
(+32°F to +120°F)
0 - 95% Relative Humidity
(0 - 85% UL Installations)
IP30 IK04 (EN 60529, EN 62262)
1 Installation Considerations
Never install the detector in an environment that causes an alarm
condition in one technology. Good installations start with the LED off
when there is no target motion. It should never be left to operate with the
tri-color LED in a constant or intermittent green, yellow, or red condition.
NOTICE!
Microwave energy will pass through glass and most common
non-metallic construction walls.
Eliminate interference from nearby outside sources.
Point the unit away from outside traffic (roads/alleys).
2 Mounting
Select a location likely to intercept an intruder moving beneath and across
the coverage pattern. Recommended mounting height range is 8 to 18 feet
(2.4 to 5.5 m).
The surface should be solid and vibration-free. (i.e. Drop tiles should be
secured if the area above the tiles is used as an air return for HVAC sys-
tems).
1. Remove the base from the enclosure by pressing the two enclosure
release tabs inward while lifting the enclosure away from the base.
Refer to Figure 2.1.
Anti-vandal locking screw holes
Figure 2.1: Opening cover
NOTICE!
Slightly rock the enclosure side-to-side during removal to overcome the
friction caused by the base-to-enclosure terminal pins.
2. Open the cover by turning counterclockwise. One side of the cover will
remain attached to the base of the detector. Do not attempt to entirely
remove the cover. Refer to Figue 2.1.
3. Route wiring as necessary to the rear of the base and through the
center hole. Refer to Figure 2.2.
Base
nclos re elease a s
Enclosure
The Cover remains
attached to the
Enclosure