Tecnosystemi Toolsplit 11132315 User Manual

Mini electronic hydrogen-leak detectors kit for verifying systems' pressure seal

Advertisement

COD. 0000000
REV. 00 / 13-06-2019
MANUALE D'USO / USER MANUAL
MINI KIT CERCAFUGHE AZOTO/IDROGENO
VERIFICA PRESSURIZZAZIONE E TENUTA IMPIANTI
MINI ELECTRONIC HYDROGEN-LEAK DETECTORS KIT
FOR VERIFYING SYSTEMS' PRESSURE SEAL
11132315
Air Curtains and
Conditioning
Accessories
Multi - Zone
Air Control System
Instruments &
Tools
utions
Tecnosystemi S.p.A.
via dell'Industria, 2/4 - Z.I. San Giacomo di Veglia
31029 Vittorio Veneto (Treviso) - Italy
Phone +39 0438.500044 - Fax +39 0438.501516
Numero Verde 800 904474 (only for Italy)
email: info@tecnosystemi.com
www.tecnosystemi.com
r Heating
C.F. - P. IVA - R.I.TV IT02535780247 Cap. Soc. € 5.000.000,00 i.v.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Toolsplit 11132315 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Tecnosystemi Toolsplit 11132315

  • Page 1 Multi - Zone Air Control System Instruments & Tools utions Tecnosystemi S.p.A. via dell’Industria, 2/4 - Z.I. San Giacomo di Veglia 31029 Vittorio Veneto (Treviso) - Italy Phone +39 0438.500044 - Fax +39 0438.501516 Numero Verde 800 904474 (only for Italy) email: info@tecnosystemi.com...
  • Page 2 Air Control System Instruments & Ventilation Tools Solutions DESCRIZIONE / DESCRIPTION Accessories For Heating Grazie a questa attrezzatura per la pressurizzazione dei sistemi di aria condizionata e refrigerazione, è possibile individuare qualunque perdita all’interno del sistema. Il cercafughe elettronico incluso nel kit rileva soltanto l’idrogeno e non è quindi innescato da altri gas. Poiché le molecole di idrogeno sono molto piccole, questa è...
  • Page 3 Air Control System Instruments & Ventilation Tools Solutions 7. Close the tap upstream of the manifold gauge and manually put the other needle at the same level of the first one Accessories For Heating 8. Wait 15/20 minutes to verify, according to the following cases: - CASE 1: if the needles remain superimposed, there isn’t any leak - CASE 2: if the needle of the pressure is gone down, it means that there is a leak inside the system.
  • Page 4 To highlight the requirement to dispose of household electrical items separately, there is a crossed-out waste paper basket symbol on the product. Tecnosystemi S.p.A. via dell’Industria, 2/4 - Z.I. San Giacomo di Veglia 31029 Vittorio Veneto (Treviso) - Italia Tel +39 0438.500044 - Fax +39 0438.501516...

Table of Contents