Summary of Contents for palmiye Skyroof Plus Hanging

  • Page 1 Installation Manual Skyroof Plus Hanging...
  • Page 2 Dear Customer, Installation manual contains suggestions and rules for fast and exact installation of our product. We recommend you to read our instruction carefully. During installation all necessary actions have to be carried out by authorized and specialized technicians. All unauthorized interventions during warranty period will invalidate the warranty.
  • Page 3 INDEX 1. Symbols, Precautions and Warnings 2. Terminology 3. Packaging 4. Installation Steps 5. Programming / Resetting of Panels and Lights 6. Sensors and Automation 7. Hardware 8. Tools 9. Frequently Asked Questions 10. Risk Table...
  • Page 4 Before starting of any assembly, maintenance or cleaning operations, make sure that you have fully understood the indications in this manual. All electrical connections for Skyroof Plus Hanging, repair of motor accessories must be made by qualified personnel. In case of any incompatibility, call Palmiye.
  • Page 5 2. TERMINOLOGY Linear Actuator Linear Actuator Hanging pipe Hanging pipe Control Unit Box Control Unit Box Panels Panels Gutter Gutter Hanging bracket Hanging bracket Linear Actuator The Linear Actuators works with 24V power. The control box provides needed power for each linear actuator.
  • Page 6 In case of anomalies, immediately stop the work and contact with hospital. Fixing elements such as screws, plugs etc. are included in the box. If not please contact service department of Palmiye. Do not use a knife to avoid the risk of ruining the paint or other materials.
  • Page 7 3.2.2. Panels BOM ID Description Fixed Pin M3x16mm Rounded Head Screw Panel Cover Panel Bottom Gasket Pannel Gasket Pannel Profile Power Pin 3.2.3. Hanging Brackets Hanging pipe Hanging pipe M30 Rod M30 Rod Hanging Bracket (Side) Hanging Bracket (Side) Hanging Bracket (Front) Hanging Bracket (Front)
  • Page 8 3.2.4. Boxes 1. Electrical Box Remote Controls, Sensors, Automations are on Electric box. It has a red label on the box. ELECTRIC 2. Metal Box U Brackets, Mounting brackets, Pillar caps. It has a blue label on the box. METAL 3.
  • Page 9: Installation Steps

    4. INSTALLATION STEPS 4.1. Wall flange connection The wall flanges must be aligned with hanging bracket. When you aligned the wall flange then you can fix it. After connection of the wall flange, hanging pie must connect to the wall flange.
  • Page 10 Final view at below. 4.2. Gutter Connection The lateral gutters must connect to back gutter as a regular.
  • Page 11 4.3. Hanging Brackets Connection 4.3.1. For Right – Left - Front The hanging brackets must carry to lateral gutters. In order to carry this bracket must fixed properly. (The lateral gutters already produced ready to fix on factory) Also, you should fix from inside with bended bracket by nut. 4.3.2.
  • Page 12 4.4. Corner Connector Connection Finally, in order to protect any lateral movement, you should use corner connector on each corner point. At the end fasten by bolt. The Final view at below.
  • Page 13: Installation Requirements

    Power only needs to be supplied to the Control Unit Box. The receiver is completely enclosed inside the Control Unit Box. • PALMIYE Reserves the right to void the motor warranty if wiring recommendations are not followed. • The Control Box works 120 or 230 V AC / 50~60 Hz Installation Requirements •...
  • Page 14 5.2. Remote Control 5.2.1. Button Configurations Skyroof Plus Hanging is integrated with actuator driven with radio control, for opening, closing or stopping the panels use the respective buttons (see figure). There are 4 different remote-control models. Pure, Patio, Lounge, Modulis;...
  • Page 15 5.3. Remote Types Situo 1 RTS Situo 5 RTS TELIS 16 Channels Battery Type 2430 Lithium LR03AAA Battery Voltage 1,5 V Thickness Width Height Colour Silver Silver & Pure Compatibility Compatible with a range of Somfy RTS enabled products Radio Frequence For indoor use Radio Range 433,42 MHz...
  • Page 17 5.4. Replacing The Battery Using a small screwdriver loosen the screws on the reverse side of the remote control and remove the back cover. Replace the battery with one 2430 Lithium 3V Battery. 5.5. Programming 5.5.1. Actuators Step 1: Select desired channel on your remote Step 2: Press the “PROGRAMMING”...
  • Page 18 Step 2: Select a channel you programmed both of lighting system. Step 3: If you want to leave the lighting on the selected channel, follow the steps below for other lighting; Step 3.1: Cut off the power as 3sec, Step 3.2: Supply a power as 10 sec., Step 3.3: Cut off the power as 3sec.
  • Page 19 5.7.2.1. RGB LED Resetting Press the programming button on the panel for 5 seconds, then press the programming button on the back of the remote for 2 seconds. 5.8. Using of Remote Control: 5.8.1. Using of Lights • “UP” button: It’s ensures Activate on your lighting system. When you press constantly “UP” button, the LED lights will up through DIMMING feature.
  • Page 20 6. SENSORS & AUTOMATION 6.1. Sensors 6.1.1. Connection to EOLIS RTS (Wind Sensor) 6.1.1.1. Cabling 6.1.1.2. Programming The motor must be in its learning mode to record an EOLIS RTS Sensor. Up to three EOLIS RTS Sensors can be memorized in a motor and one EOLIS RTS Sensor can be memorized in several motors.
  • Page 21 6.1.1.3. Functioning The WIND threshold can be adjusted by a potentiometer accommodate wind speed between 10 to 50km/h (6 to 31mph) • When the wind speed exceeds the threshold set by the EOLIS sensor RTS, an UP order is given to the pergola after 2 sec. •...
  • Page 22: Setting Instructions

    adjusted by two potentiometers, one for wind speed and the other for daylight intensity. • The adjustment range is between 9 – 50 km/h (6 – 31 mph) for the WIND and between 0 to 50 kilolux for the SUN •...
  • Page 23: Mounting Instructions

    • Enter the “DEMO” mode • By pressing MODE button > 2 sec. > the light will start blinking for • 30 sec. + feedback motor. • Adjust the sun threshold with the potentiometer • The blinking led will be green once you have reached the current sun level. •...
  • Page 24 6.2.1.5. Connection to ONDEIS (Rain) sensor • Rain sensor requires a dry contact input. Our single motors (ALTUS) works with RTS • In order to use ONDEIS rain sensor you must use Dry Contact Transmitter • The RTS motors can communicate with dry contact transmitter or RS485 (multiple dry contact transmitter.
  • Page 25 6.3. Automation 6.3.1. Adaptable to Somfy systems Our Retractable Pergola System can control by Somfy Home Automation Smart System which is CONNEXOON® Window RTS You can download from below link: For IOS system: https://apps.apple.com/tr/app/connexoon-window-rts/id1168009218?l=tr For ANDROID system: https://play.google.com/store/apps/details?id=com.somfy.connexoon_window&gl=TR • The retractable pergola system motors can control by CONNEXOON® Window RTS application on smart phone.
  • Page 26 • The dry contact connector n⁰4 has per default, the RTS address n⁰4 • The dry contact connector n⁰5 has per default, the RTS address n⁰5 • Press the programming button on the back of the RTS control point or the RTS receiver until the motor jogs.
  • Page 27 7. HARDWARE 7.1. Hanging Bracket Set Hanging Bracket Hanging Fixing Clamp Set Item code: DMR.APR.P1101.ELGV Set Item code: DMR.APR.P1101.ELGV Hanging Fixing Clamp Hanging Fixing Clamp Hanging Bracket Hanging Bracket 7.2. Hanging Bracket - Gutter Bolts M8x25mm Bolt M8x25mm Bolt M8x25mm Bolt...
  • Page 28 7.3. Hanging Brackets – Hanging Pipe Bolt M16x50mm bolt M16x50mm Bolt M16x50mm Bolt 7.4. Hanging Fixing Clamp – Gutter Screw M4,2x19mm self-drilling screw M4,2x19mm Self drilling screw M4,2x19mm Self drilling screw...
  • Page 29 7.5. Corner connector – Gutter Bolt M8x25mm bolt M8x25mm bolt M8x25mm bolt DMR.APR.G1181.ELGV - Corner connector DMR.APR.G1181.ELGV - Corner connector...
  • Page 30: Product Code

    8. TOOLS Image Product Description Product Code Palmiye T-Shirt for Installation teams HZM.ISG.G1009.BRUT Palmiye Trousers for Installation teams HZM.ISG.G1014.BRUT Palmiye Waistcoat for Installation teams HZM.ISG.G1013.BRUT to block the passage Sealant | NP1 Dark of water through the HRD.KMY.C0018.KAHV Brown surface or joints or...
  • Page 31 Image Product Description Product Code to anchor rods to Epoxy HRD.KMY.G1027.BRUT concrete to fix and stabilaze M12 Rod products to ground/ HRD.CVT.G0100.ZINC wall/ceiling to fix and stabilaze M30 - Rod Galvanized products to ground/ HRD.CVT.G0105.ZINC wall/ceiling part to to fix and M12 Rondela Washer stabilaze products to HRD.CVT.G1062.PSMZ...
  • Page 32: Installation Tool List

    INSTALLATION TOOL LIST Tool box with wheel 1 pc Spiral grinder 1 pc Batery driller. 1 pc Electric impact drill 1 pc Lighting 2 pc Extansion lead 2 pc Ladder 2 pc Tape measure 5m 1 pc Tape measure 10m 1 pc Water gauge 2 pc...
  • Page 33 Allen wrench set 2 Set Socket wrench 1 pc Screw driver 1 Set Plastic hammer 1 pc Iron hammer 2 pc Electrical screw driver 2 pc Cutter 1 pc Slicon gun 2 pc Bits 2 Set PH2X100 Bits 2 pc APEX 493 A Bits 2 pc Insulating Tape (Black)
  • Page 34: Frequently Asked Questions

    9. FREQUENTLY ASKED QUESTIONS REASON HOW TO RESOLVE? Check the switch of the current distri- The motor is not energized bution board connected to the motor is on. The product motor would not start Disconnect the power and wait for 15 The motor has no regular minutes then try to start again.
  • Page 35 R&D department, all of our products have been awarded the CE quality certificate. By attaching the CE mark to its products, Palmiye declares that it meets the EU safety, health, and environment requirements.
  • Page 36 www.palmiye.eu...