Download Print this page

Advertisement

Quick Links

MODEL PART DIAGRAM
FRONT
Control Panel
Front Panel
PACKAGE CONTENTS
(1) Pre-Filter
Unit
(8) Activated Carbon Filters
(2) True HEPA Filters
* For a Certified Refurbished Air Purifier, there will be 4 New Carbon Filters and 1 True HEPA Filter included;
equivalent to a 1-year supply.
WHERE TO USE
Allow 12 ~ 18 in. of space between TVs, radios, and other
electronics.
electronics may cause product malfunction.
Place indoors away from direct sunlight.
may cause product malfunction or failure.
Only place on hard, flat surfaces.
surfaces may result in abnormal noise and vibrations.
12~18 in
Allow at least 12 ~ 18 in. from walls for maximum air flow
12~18 in
4-STAGE AIR PURIFICATION
1
2
Pre-Filter
Activated Carbon Filter
INITIAL OPERATION
1.
Remove the front panel by grasping its upper edge
and gently pulling forward.
2.
Remove the Pre-Filter, then the bag of filters behind it.
3.
Remove filters from protective plastic bag.
4.
Install the filters until they fit securely in place.
03. True HEPA Filter (back)
02. Activated Carbon Filter (middle)
01. Pre-Filter (front)
5.
After filters are installed, close the front panel.
6.
Insert the power cord into an electrical outlet.
MAINTENANCE
When to Replace Filters
Filter
Indicator Light
Pre-Filter
none
Activated Carbon Filter
none
True HEPA Filter
• When the Check Filter Indicator LED is on, it is time to replace the Filter.
• Intervals between filter replacement may vary depending on environment.
REPLACING FILTERS
Resetting Filter Life:
After replacing your True HEPA Filter, place the Pre-Filter back in and close the Front Panel.
While the unit is on, hold the Filter Reset Button for at least 5 seconds until you hear the beep.
After the beep, the Filter Replacement Indicator will disappear. The True HEPA Filter is now reset.
BACK
Air Outlet
Vent
Handle
Power Plug
User
Alexa Setup Guide /
Manual
Wi-Fi Setup Guide
Electromagnetic interference from certain
Direct exposure
Flimsy or slanted
Air Purification means it
removes inanimate particles
3
4
True HEPA Filter
PlasmaWave
Latch
03
02
01
Latch
When to Ser vice
When to Replace
Every 14 days
Permanent
Every 3 months
CAN'T BE WASHED
Lasts Approx.
12 months
1712-0096-00
CONTROL PANEL
01. Auto Mode Indicator -
The LED "Auto" light
will indicate when Auto Mode is activated.
02. Air Quality Indicator -
Color coded LED
light indicates one of three levels of Air Quality:
Red (poor), Amber (fair), and Blue (good).
03. Fan Speed Indicator -
Indicates the current
fan speed.
04. Sleep Mode Indicator -
light will indicate when Sleep Mode is on.
05. Filter Replacement Indicator -
indicates when it is time to change the filter.
06. Filter Reset Button -
After replacing the
True HEPA Filter, use a small object such as a
paper clip, to press and hold the Filter Reset
Button for at least 5 seconds until the Filter
Replacement Indicator turns off.
07. Smart Sensor -
Detects the amount of
odorous gas in the environment. When in Auto
mode, the fan speed adjusts according to the
detected amount of gas.
08. Power Button
- Turns the unit on or off.
During the first 30 seconds of powering up, the
Air Quality Indicator will cycle through Blue,
Amber and Red colors.
• Smart sensor takes approximately 4 minutes
to detect the air quality in the environment
before normal operation begins.
09-1. Fan Speed/Auto/Sleep Buttons -
Fan Speed arrow buttons to set the desired
fan speed. Fan Speeds cycle over in this
sequence: Auto, Low, Medium, High, Turbo,
Sleep, Auto.
Auto Mode: Automatically adjusts fan speeds
according to your indoor air quality. The fan
speed will adjust to low when air quality is good,
medium when fair, and to high when poor.
®
CLEANING CARE
Cleaning the Filters:
Use a vacuum cleaner or soft brush to clean
the Pre-Filter.
• If it is excessively soiled, rinse in room
temperature water. Do not use detergent or
soap. Allow the filter to dry for 24 hours or
more before using. Intervals between filter
cleaning may vary depending on the air
quality. Do not use hot water over 104
volatile fluids such as paint thinner.
N O T I C E
• When cleaning the unit, always unplug the power cord
first and then wait until the unit has cooled down.
• Never disassemble, repair, or modify this unit yourself.
• Do not use flammable sprays or liquid detergents.
• Do not allow children to clean or maintain the unit.
• Before cleaning or maintaining, ensure unit is unplugged.
• Do not use benzene, alcohol, or other volatile fluids,
which may cause damage or discoloration.
Contact Winix for product related inquiries and customer service
• Dedicated Call Center:
• Website: www.winixamerica.com
To expedite service, please specify the model name and number, the nature of the problem, your
contact information, and your address.
For Troubleshooting or Frequently Asked Questions, please visit: https://winixamerica.com/faq/
01
07
08
09
The LED "Sleep"
Sleep Mode: When Sleep Mode is activated,
the Air Quality Indicator LED light is disabled.
LED light
• Fan speed will automatically set to minimum
speed (lower than 'Low') which will be
nearly silent. When Sleep Mode is active,
®
PlasmaWave
will be disabled, but it can be
turned back on.
09-2. PlasmaWave
the buttons
+
Press the Plasmawave
is on to enable or disable this feature. By
default, PlasmaWave
unit is powered on. When the unit is running,
you may hear a chirping or buzzing sound.
The sound is from large particles passing
through PlasmaWave
not signify product failure.
10. PlasmaWave
whether PlasmaWave
11. Wi-Fi Button -
activate pairing mode. When Wi-Fi is paired,
press the button to turn Wi-Fi off or back on.
12. Wi-Fi Indicator -
Use the
Fi feature. When in the pairing state, the Wi-Fi
LED flashes. When paired successfully, the Wi-Fi
LED will be a solid white light.
13. Light Sensor -
ambient light in the environment. When in Auto
Mode, the light sensor detects when to put the
unit into Sleep Mode.
Winix Smart Wi-Fi Setup -
Guide Guide provided inside the box.
Cleaning the Exterior & Interior:
Wipe with a soft damp cloth using room
temperature water.
• Afterwards, wipe it down with a dry cloth.
Open the front panel and clean the interior
with a vacuum cleaner.
• For optimal performance, clean every 1 - 2
o
F or
months.
SPECIFICATIONS
Model
Voltage
Power Rate
Dimensions
Weight
Filter SKU
Exterior design, and product specifications may be changed
without prior notice to improve product performance.
(877) 699-4649
02
03 04 05 06
10
11
12
13
®
Button - Press and hold
for 3 seconds
®
button when the unit
®
is enabled whenever the
®
, it is normal and does
®
Indicator -
Indicates
®
is enabled or disabled.
Press for 3 seconds to
Enables or disables the Wi-
Detects the amount of
Refer to the Wi-Fi
C545
AC 120 V / 60 Hz
65 W
13.7"W × 8.4"D × 20.5"H
11 lbs
Filter S: 1712-0096-00

Advertisement

loading

Summary of Contents for Winix C545

  • Page 1 • Intervals between filter replacement may vary depending on environment. Exterior design, and product specifications may be changed which may cause damage or discoloration. without prior notice to improve product performance. Contact Winix for product related inquiries and customer service REPLACING FILTERS • Dedicated Call Center: (877) 699-4649 •...
  • Page 2 This warranty is valid only in the USA and Canada. * Certified Refurbished Air Purifiers come with a 1-year warranty. All Winix Certified Refurbished Air Purifiers go through a detailed inspection and refurbishment process to ensure all quality and performance standards are met.