Table of Contents

Advertisement

Available languages

Available languages

Quick Links

8175 W. Buckeye Rd., Phoenix, AZ 85043
Toll Free: 1.800.621.5886 • Phone: 480.893.7607 • Fax: 480.753.3397
Paramount@1Paramount.com • www.1Paramount.com
US and Foreign patents and patents pending
see www.1paramount.com/support/patent-numbers/
Paramount products are designed by Paramount in Phoenix, Arizona, United States of America
004-027-8703-00 R02 ECN_2208
INSTALLATION &
OWNER'S MANUAL
PUB111821 ©2021 Hayward Industries, Inc.

Advertisement

Table of Contents
loading

Summary of Contents for Paramount Fitness EDC

  • Page 1 INSTALLATION & OWNER’S MANUAL 8175 W. Buckeye Rd., Phoenix, AZ 85043 Toll Free: 1.800.621.5886 • Phone: 480.893.7607 • Fax: 480.753.3397 Paramount@1Paramount.com • www.1Paramount.com US and Foreign patents and patents pending see www.1paramount.com/support/patent-numbers/ Paramount products are designed by Paramount in Phoenix, Arizona, United States of America 004-027-8703-00 R02 ECN_2208 PUB111821 ©2021 Hayward Industries, Inc.
  • Page 2: Table Of Contents

    Plumbing The Canister ....................7 Plumbing Before The Equipment Header Or Pump ..........7 Plumbing After The Suction Side Header And Before The Pump..... 8 Pressure Testing ......................9 Home Owner Instructions: Cleaning The Basket ..........10 Winterizing The EDC Canister ................11...
  • Page 3 Signal Words and Symbols Used In This Manual This Owner’s Manual and Installation Guide contains specific precautions and symbols to identify safety-related information. You will find DANGER, CAUTION, WARNING, NOTICE and SAFETY INSTRUCTIONS symbols which require special attention. Please read them carefully and follow these precautions as indicated! They will explain how to avoid hazards that may endanger you or persons using or maintaining your pool or spa.
  • Page 4 Fully secure lid assembly to canister before applying pressure. If lid isn’t fully secured it will DANGER result in serious injury or death. Do not remove this lid when this canister is under pressure. Removing this lid with the DANGER canister under pressure will result in serious injury or death.
  • Page 5 Clear lid & bayonet assembly The inlet port is 2½" 2 ports for schedule 40 plumbing in the pipe size on optional Clear the ID. The OD O3 ozone water accepts a 3" purifi er or vacuum coupler (spigot) gauge The outlet port is 2½"...
  • Page 6: Installing The Canister

    LOCATING THE CANISTER FOR BELOW GRADE INSTALLATION The EDC canister can be installed below grade. The minimum hole footprint is 24" x 24". The hold depth varies for per your requirements. Backfi ll the hole after plumbing; be sure to compact the soil around the canister to ensure stability.
  • Page 7: Plumbing The Canister

    Plumb the suction header as you Plumb a suction line from an outlet normally would. From the suction fitting to the inlet port of the EDC. header plumb the suction line into From the bottom outlet of the EDC the inlet port of the EDC. There go directly into the header with must be 8"...
  • Page 8: Plumbing After The Suction Side Header And Before The Pump

    EDC or a plumbing manifold. The EDC canister is made of a 30% glass fi lled Noryl material for strength. This requires priming the sockets times, before applying the PVC glue.
  • Page 9: Pressure Testing

    The EDC canister has 3 optional ports. Two of the optional ports are ¼" NPT blind ports located approximately 18" from the base. The third optional port is located on the bottom side of the EDC. It is sized to accept ½" pipe or a ¾" fitting.
  • Page 10: Home Owner Instructions: Cleaning The Basket

    HOME OWNER INSTRUCTIONS: CLEANING THE BASKET Fine mesh bag Debris basket Ring Make sure to turn off the pump. NOTICE To clean the basket you must remove the lid. Turn the two handles counterclockwise one quarter turn. Set the lid aside making sure to keep the o-ring clean.
  • Page 11: Winterizing The Edc Canister

    When replacing the lid and ring make sure that the top of the EDC canister is free from all dirt and debris and the o-ring on the lid is clean. Paramount does not recommend using lube on the lid o-ring as it attracts dirt and debris. Some lubricants can cause swelling and damage to the o-ring.
  • Page 12 Paramount Part# Description 004-152-4516-00 EDC Canister Complete 005-152-2205-00 Lid Assembly includes, clear lid, ring, o-ring 005-152-2206-00 O-Ring 005-152-2207-00 Basket Assembly 005-152-2208-00 Canister Replacement body only 004-152-4517-00 Optional Fine Mesh Bag...
  • Page 13 GUIDE D’INSTALLATION ET MANUEL DU PROPRIÉTAIRE 8175 W. Buckeye Rd., Phoenix, AZ 85043 Toll Free: 1.800.621.5886 • Phone: 480.893.7607 • Fax: 480.753.3397 Paramount@1Paramount.com • www.1Paramount.com US and Foreign patents and patents pending see www.1paramount.com/support/patent-numbers/ Paramount les produits sont conçus par Paramount in Phoenix, Arizona, Les états-unis 004-027-8703-00 R02 ECN_2208 PUB111821 ©2021 Hayward Industries, Inc.
  • Page 14 Tuyauterie Avant Le Port De L’appareil Ou La Pompe ........19 Tuyauterie Après L’extrémité Aspirate Et Avant La Pompe ........20 Essai De Pression .......................21 Consignes À L’intention Du Propriétaire : Nettoyage Du Panier .....22 Hivérisation De La Boîte Filtrante EDC ..............23...
  • Page 15 MOTS ET SYMBOLES UTILISÉS DANS LE PRÉSENT GUIDE La présent manuel du propriétaire et guide d’installation contient des précautions et des symboles spécifiques visant à vous transmettre des renseignements sur la sécurité. Les symboles et les mots DANGER, PRÉCAUTION, AVERTISSEMENT, et RENSEIGNEMENT DE SÉCURITÉ doivent faire l’objet d’une attention particulière.
  • Page 16 Ne pas enlever ce couvercle lorsque la boîte filtrante est sous pression, au risque de vous DANGER exposer à un risque de lésion physique grave ou mortelle. Ne pas se tenir au-dessus du couvercle lorsque la boîte filtrante est sous pression, au risque de DANGER vous exposer à...
  • Page 17 Couvercle transparent et ensemble de raccord à baïonnette L’orifi ce d’admission Ports pour la est un tube de tuyauterie du 2½" de DI et purifi cateur d’eau de calibre 40. (facultatif) Clear O3 Le DE peut ozone, ou le tuyau être relié...
  • Page 18: Installer La Boîte Filtrante

    INSTALLER LA BOÎTE FILTRANTE SOUS LE NIVEAU DU SOL La boîte fi ltrante peut être installée sous le niveau du sol. Creuser un trou d’au moins 24” x 24”/61 cm x 61 cm, sans restriction de profondeur. Remblayer le trou après y avoir installé la tuyauterie, en veillant à bien tasser le sol autour de la boîte fi ltrante afi n d’en assurer la stabilité.
  • Page 19: Tuyauterie De La Boîte Filtrante

    (dont vous voulez recueillir les débris) au port d’admission de l’EDC. Plombez la tête de succion comme Du bas de la prise de l’EDC, allez vous le feriez d’habitude. À partir directement dans la tête avec les de la tête de succion, plombez la autres items de succion.
  • Page 20: Tuyauterie Après L'extrémité Aspirate Et Avant La Pompe

    Veiller à toujours laisser au moins 8 po./20 AVIS cm de conduite entre l’entrée aspirante de la pompe et le premier raccord, qu’il s’agisse d’un EDC ou d’une manivelle de plomberie. La boîte fi ltrante EDC est composée de Noryl renforcé à 30% en verre pour en rehausser la force.
  • Page 21: Essai De Pression

    Si un essai de pression est nécessaire, vous pouvez utiliser le manomètre du système pour mesurer la pression d’essai, ou utiliser les ports aveugles/blind ports NPT de ¼" de la boîte filtrante EDC, ce qui requiert de percer les ports NPT de ¼". Utiliser un trépan de ", en ayant soin de ne pas endommager...
  • Page 22: Consignes À L'intention Du Propriétaire : Nettoyage Du Panier

    Note : Le couvercle ne peut être séparé de l’anneau. Avant de remettre le couvercle et l’anneau, assurez-vous que la partie supérieure de la boîte filtrante EDC soit sans saletés ni débris, et que l’anneau circulaire soit propre. Paramount ne recommande pas l’utilisation de lubrifiants sur l’anneau circulaire du couvercle, puisqu’ils accumulent la saleté...
  • Page 23: Hivérisation De La Boîte Filtrante Edc

    HIVÉRISATION DE LA BOÎTE FILTRANTE EDC Pour les zones sujettes au gel, le bidon EDC doit être hiverné. Pour hiverner, enlevez le couvercle du bidon et le couvercle de la pompe. Utilisez un aspirateur de fluide ou de solide pour aspirer toute l’eau du EDC. Replacez le couvercle du EDC et effectuez votre processus d’hivernation habituel.
  • Page 24 Pièce Paramount Description 004-152-4516-00 Boîte filtrante EDC Complete Ensemble-couvercle, avec couvercle transparent, pince de fixation de 005-152-2205-00 type baïonnette et anneau circulaire 005-152-2206-00 Anneau circulaire 005-152-2207-00 Ensemble panier 005-152-2208-00 Pièce principale de remplacement pour la boîte filtrante 004-152-4517-00 Sac fileté facultatif...

Table of Contents