Model QMR6
Installation, Operation, and Maintenance

MAINTENANCE

NOTE:
To avoid personal injury, permit only qualified personnel to perform maintenance on this lift.
See repair parts breakdown for replacement parts.
ALWAYS: Keep all bolts tight. Check periodically.
ALWAYS: Keep lift clean. Raise lift when cleaning floor area.
DAILY: Check lock bar handle and release mechanism for damage or binding.
WEEKLY: Inspect all lift parts for signs of damage due to improper use.
MONTHLY: Lubricate lock bar pivot bolt and lock bar handle pivot points.
MONTHLY: Lubricate all hinge joints if there are signs of rusting.
SEMI-ANNUALLY: Check fluid level of lift power unit and refill if required. Use only Dexron III ATF or 10wt
anti-foam, anti-rust hydraulic oil. If fluid is required, inspect hose and connections and cylinder seals. Repair
as required.