Service Testing Procedures - Whirlpool WFC80602RT-D Service Manual

Essential trs
Table of Contents

Advertisement

Touch any button under the Power Saving mode to exit the mode. The screen lights up, and the button functions are restored.
The Power Saving mode will be activated after 10 s.
It is a default function.
VI. Service Testing Program
6.1 Test for LED and buttons
PCB test mode:
Press the "Power (SW1)" button to turn it on.
your heart" key and press the "Start (SW2)" key for three times to enter the PCB substrate inspection mode. The following
information is displayed:
Press " Rinse " button
Press " Rinse " button
Press " Rinse " button
Press " Rinse " button
Press " Rinse " button
Press " Rinse " button
Press " Rinse " button
Press " Rinse " button
Press " Rinse " button
The water level sensor adopted in the detection platform is the model 61-C, the empty level parameter between 2968 - 2A62.
The door lock light illuminated shows the door lock at the closed state
Turns / minute
Flashing indicates 3D abnormality
When it shows 00, press Start button to enter the item for check.
Analog load display ○: OFF ●: ON
Under the no-drum cleaning procedure, press and hold the "Wash with
Display Content
Model No.
Model No.
Function Information
Version information
Version information
Version information
Protocol version
information
Water level information
Temperature information
00
Remark
100
ITE and D (for Whirlpool) switch display
B(single
washing
model)/BH
UP(upper drainage) switching display
A represents the version number
B represents Inverter version number
C represents main control version number
d indicates that the communication protocol version
number is displayed alternately(For example, D02
201 indicates that the display protocol version is 01
and the main control protocol version is 201.)
Indicates water level frequency (hexadecimal)
(double light when water level is greater than 3
levels)
H XX indicate the drying air duct temperature
XX Indicates water heating temperature
Ready to enter the automatic load detection state
16
(drying)
and

Hide quick links: