  • Page 1 4-Piece Digital Measuring Kit Effective April 2021 Review full instructions prior to use for important safety information. Always check Rockler.com to confirm that you are using the most recent version of instructions for your product.
  • Page 2: General Safety Warnings

    Use only recommended accessories. Before using the Rockler Digital Measuring Kit: READ, UNDERSTAND and FOLLOW ALL INSTRUCTIONS AND SAFETY WARNINGS. KEEP THESE INSTRUCTIONS READILY AVAILABLE FOR FUTURE REFERENCE.
  • Page 3 GENERAL SAFETY WARNINGS > Before using this product, review and verify that all tools to be used with it have safety equipment installed and are in proper working order as defined by the tool’s owner’s manual. > Do not use this product until you have read and are confident you understand: •...
  • Page 4 GENERAL SAFETY WARNINGS • Dress appropriately. Secure loose clothing, remove all jewelry and tie up long hair before using this product; • ALWAYS wear safety glasses, hearing protection and respiratory protection that complies with NIOSH/OSHA/ANSI safety standards; • Use dust collection tools and dust face masks to reduce exposure to dust;...
  • Page 5 GENERAL SAFETY WARNINGS Danger indicates a hazardous situation that, if not avoided, will result in death or serious injury. Warning indicates a hazardous situation that, if not avoided, could result in death or serious injury. Caution indicates a hazardous situation that, if not avoided, may result in minor or moderate injury or property damage.
  • Page 6 PRODUCT SPECIFIC SAFETY WARNINGS > Keep out of reach of children. The digital measuring tools are NOT toys. > This product contains a rare earth (neodymium) magnet and may affect internal medical devices such as pacemakers. Keep away from internal medical devices.
  • Page 7 GENERAL SAFETY WARNINGS PRODUCT SPECIFIC SAFETY WARNINGS > The Rockler Digital Measuring Kit is composed of sensitive tools. Do NOT drop the tools or try to disassemble them. > Some of the digital measuring tools could have sharp edges. Exercise caution in handling.
  • Page 8 Digital Height Gauge > Do not attempt to use the Digital Height Gauge on high-vibration machines. Technical Specifications Accuracy: ±0.1mm/±0.004" Resolution: 0.05mm/0.002" Working Range: Scale: 0~80mm/0"~3"; Needle: 0~50mm/0"~2" Power Supply: One CR2032 3V button cell (included) Working temperature: 32°F to 122°F/0°C to 50°C Working humidity : ≤85% Button Locations and Functions (Fig.
  • Page 9 Installing/Changing the Battery The Digital Height Gauge uses one CR2032 3V battery. 1. Pull up on the tab on the top of the digital readout to remove the battery holder. Fig. 1. 2. Remove the old battery and install a new one, making sure that the side marked “+”...
  • Page 10 Zeroing out the Gauge 1. Loosen the thumbscrew on the right side of the digital indicator (if necessary). 2. Position the Digital Height Gauge so its feet are flat on a flat surface. Lower the center rule until it touches the surface.
  • Page 11: Troubleshooting

    the Gauge in ABS mode; then move the center rule up to 1/8" and push the “INC/ABS” button to switch to Incremental Mode. The digital indicator will switch to “0”. Tighten the thumbscrew to secure the setting, set the bit height and make the first pass.
  • Page 12 Digital Angle Rule Technical Specifications Accuracy: 0.3° Resolution: 0.1° Working Range: 0°~ 360° Power Supply: One CR2032 3V button cell (included) Working Current: ≤120µA Working temperature: 32°F to 122°F/0°C to 50°C Working humidity : ≤85% Button Function (Fig. 2) ON/OFF: Short press turns device on. (Moving the scale also turns on the readout.)A second short press turns off the device.
  • Page 13 Installing/Changing the Battery The Digital Angle Rule uses one CR2032 3V battery. 1. Push up on the tab protruding from the bottom of the digital readout. You will see the top of the battery holder emerge from the top of the digital readout. Fig. 2. 2.
  • Page 14 Operating Instructions Turn the knob next to the digital readout to control the tension for opening and closing the Digital Angle Rule. Rotate clockwise to tighten and counterclockwise to loosen. The Digital Angle Rule can be zeroed out in two different ways – fully closed or fully open –...
  • Page 15 Digital Calipers Technical Specifications Accuracy: ±0.03mm/±0.0005" Resolution: 0.01mm/0.0005" Working Range: 0-150mm/0"-6" Power Supply: One LR44 Battery (included) Working Temperature: 32°-122°F/0°-50°C Working Humidity: ≤85% Parts/Functions ( Fig. 3 p. 16) OFF/ON button: Short press turns device on; another short press turns device off. ZERO button: Short press sets device to zero at that position.
  • Page 16 Step gauge (not visible) Inside Jaws Outside Jaws Mm/inch/F ON/OFF Button button Zero Button Locking Screw Battery Cover Thumbwheel Depth gauge (not visible) Fig. 3...
  • Page 17 Outside jaws: Used to measure the thickness, diameter or other exterior dimension of a workpiece. Fig. 4. Fig. 4 Inside jaws: Used to measure the interior diameter or dimension of a hole, dado, groove, mortise or other opening in a workpiece.
  • Page 18 Installing/Changing the Battery Digital Calipers use one LR44 battery. 1. Slide the battery cover in the direction indicated by the arrow ( 2. Remove the old battery and install a new one, making sure that the side marked “+” faces up. 3.
  • Page 19 Magnetic Angle Gauge Technical Specifications Accuracy: ±0.1° for 0° and 90°; ±0.2° for all other angles Resolution: 0.1° Working Range: 4 x 90° Power Supply: One AAA alkaline battery (included) Working Temperature: 32°-122°F/0°-50°C Weight: 0.082kg Installing/Changing the Battery > The Digital Calipers use one AAA alkaline battery. >...
  • Page 20 Battery Compartment Fig. 7 ON/OFF Zero Button Button Fig. 8...
  • Page 21: Operation

    Operation > The Magnetic Angle Gauge automatically shuts off after about 5 minutes if there’s no movement or no buttons are pushed. > The Magnetic Angle Gauge has two operational modes: Absolute Mode and Relative Measuring Mode. In Absolute Mode (the default), the gauge measures the degree of angle from horizontal.
  • Page 22 Do not move the device until calibration has been completed. 4. Calibration is complete when the display stops flashing and the readout shows 0.00 and ABS. Check Rockler.com for updates. If you have further questions, please contact our Technical Support Department at 1-800-260-9663 or support@rockler.com 89409 Distributed by Rockler Companies, Inc.