Magnetron and Magnetron TCO

WARNING: Always be certain the capacitor is
discharged before servicing. (See
) Mechanically discharge by placing an
Diode.
insulated handle screwdriver between the diode
connection of the capacitor and the oven chassis
ground.
Note: The capacitor has an internal discharge
resistor that automatically discharges the capacitor
when the oven turns OFF. Under normal operation,
the capacitor should fully discharge within 30
seconds.
The oven must be removed to access the
magnetron. (See
Oven Removal / Partial Removal.
The magnetron is located behind the top access
cover. The top access cover is held in place by 2
Phillips-head screws. The magnetron is held in
place by 4 Phillips-head screws. The magnetron
thermostat must be disconnected before removing
the magnetron.
Magnetron TCO
The magnetron TCO is attached to a bracket
mounted to the magnetron. The magnetron bracket
is held in place by a single Phillips-head screw.
This position of the magnetron TCO allows it to
sense the temperature of the magnetron.
The magnetron TCO opens at 302°F and cannot be
reset. If the magnetron TCO opens, it will disable all
oven functions including the display.

High Voltage Transformer

WARNING: Always be certain the capacitor is
discharged before servicing. (See
Capacitor and
Diode.
insulated handle screwdriver between the diode
connection of the capacitor and the oven chassis
ground.
Note: The capacitor has an internal discharge
resistor that automatically discharges the capacitor
when the oven turns OFF. Under normal operation,
the capacitor should fully discharge within 30
seconds.
The oven must be removed to access the high
)
voltage transformer. (See
Removal.
behind the top access cover. The top access cover is
held in place by 2 Phillips-head screws.
The transformer is held in place with 4 Phillips-head
screws. Two of the screws are recessed from the
top of the outer cover. Access holes are provided. A
magnetic screwdriver is necessary to capture these
screws.
Magnetron
Magnetron TCO
When disconnecting the primary and secondary
wire connections, note the wire locations. The wire
connectors use releasing locking tabs.
Check the high voltage transformer windings for
approximate resistance value between:
Red to white (primary) - .5 Ω
Red/Black to chassis ground (secondary) - 87 Ω
Magnetron harness (fi lament high voltage) - .2 Ω
– 31 –
) Mechanically discharge by placing an
Oven Removal / Partial
) The high voltage transformer is located
Transformer
ELECTRICAL TERMINAL
RELEASE/LOCKING TAB
Capacitor and

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scb 1000Scb 1001Zsc 1000Zsc 1001

Table of Contents