To remove the power board:
1.
Remove the control panel assembly. (See
.)
Panel Assembly
2.
Disconnect wire harnesses from the power
board at locations CN4, CN7, and CN11.
3.
Remove the 4 Phillips-head screws that attach
the power board to the control panel bracket.
4.
Lift the power board to clear the retaining tab.
Tab
CN11
CN4
Control
CN7
– 26 –
To remove the relay board:
1.
Remove the control panel. (See
.)
Assembly
2.
Peel back the foam tape.
3.
Disconnect the wire harness from the power
board at location CN11 and release the harness
from the wire retainer.
4.
Disconnect wire harnesses from the relay board
at locations CN1 and CN3.
5.
Remove the 5 Phillips-head screws that attach
the relay board to the control panel bracket.
6.
Lift the relay board to clear the retaining tab.
Wire Retainer
Foam Tape
Tab
CN3
Control Panel
CN11
CN1
(Continued Next Page)