Download Print this page

Zap ACC514 Quick Start Manual page 2

Electric bolts

Advertisement

Mounting
ACC514
1. Cut a rebate in the door for the detector plate, and
cut the hole for the electric bolt using the template
provided.
2. Ensure a channel or hole is made for the cables and
ensure they are protected by using a protection guard
or conduit if exposed.
3. Then fix the bolt to the door frame and the plate to
the door using the screws provided.
ACC516
Mark the mounting holes for both the electronic bolt
and detector plate to the door frame and door.
Then fix the bolt to the door frame and the plate to the
door using the screws provided.
Ensure the cables for the lock are protected by using a
protection guard or conduit.
Troubleshooting
If the door release is not activating the lock then there is likely a shorted wire, open circuit or some other failed
device in the circuit.
To identify where the fault is, each wired connection in the circuit needs to be tested; working from the door
release progress through, including the power supply and the lock.
If the fault is with the door release then check the connection wires for continuity and for trapped wires. Check
for water ingress on the wired connections. Check the polarity in the power connections and ensure the
connections are connected to the proper terminals.
ACC514
Design
Mortice Mount
Delay
Adjustable: 0 / 3 / 6s
Relay Output
NO / COM / NC
Voltage
12V DC / 80mA (Holding)
Peak Current
1A (<1s)
Led Colour
N/A
Construction
Metal
Dimensions
(H) 200 x (W) 34 x (D) 41mm (Bolt)
All specifications are approximate. System Q Ltd reserves the right to change product specifications or features without notice. Whilst every effort is
made to ensure that these instructions are complete and accurate, System Q Ltd cannot be held responsible for any losses, no matter how they arise,
from errors or omissions in these instructions, or the performance or non-performance of the equipment refered to.
Quick Start Guide - qACC514, qACC516
This symbol indicates that equipment must not be mixed with general household waste. For treatment, recovery and recycling please return to your local designated
2
WEE/CG0783SS collection point as defined by your local council.
Zap is a registered trademark of System Q Ltd
ACC516
Surface Mount
Adjustable: 0 / 3 / 6s
NC / COM
12V DC / 170mA (Holding)
1A (<1s)
Powered: Red / Locked: Green
Metal
(H) 150 x (W) 34 x (D) 28mm
Electric Bolts
Copyright 2022 System Q Ltd

Advertisement