W&H MN-111 Troubleshooting Manual
Hide thumbs
Also See for MN-111
:
Instructions for use manual
(104 pages)
,
Instructions for use manual
(102 pages)
1
2
Table Of Contents
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
page
of
22
Go
/
22
Contents
Table of Contents
Bookmarks
Table of Contents
Table of Contents
About this Manual
Conformity
Symbols and Messages
Safety Warnings
Emergency Door Opening
Errors
Checks and Actions
Other Problems
Water Tank Problems
Water Spillage Problems
Printer Problems
USB Device Problems
Display Problems
Other Problems and Malfunctions
Advertisement
Quick Links
1
Errors
Download this manual
Errors and Troubleshooting
SERVICE BOOK
ENG - Rev08
MN-111 110 V / 220 V
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the MN-111 and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for W&H MN-111
Medical Equipment W&H lexa MN-111 100-125 V ac Instructions For Use Manual
(104 pages)
Laboratory Equipment W&H Lexa MN-111 Instructions For Use Manual
(102 pages)
Steriliser W&H Lara RIL-117 Instructions For Use Manual
(138 pages)
Steriliser W&H Lexa MINI Instructions For Use Manual
(104 pages)
Steriliser W&H Lisq VA131-17 Instructions For Use Manual
(94 pages)
Steriliser W&H lexa RIS-303 Instructions For Use Manual
(106 pages)
Summary of Contents for W&H MN-111
Page 1
Errors and Troubleshooting SERVICE BOOK ENG - Rev08 MN-111 110 V / 220 V...
Page 2
Tool list Repair and Spare Parts Torque values for bolts and nuts Repair and Spare Parts Water consumption table Test instructions MN-111 | Service book | Errors and Troubleshooting MN-111 ENG Rev08 | 2019/06/21 | © 2019 W&H Sterilization Srl...
Page 3: Table Of Contents
Checks and actions Other problems Water tank problems Water spillage problems Printer problems USB device problems Display problems Other problems and malfunctions MN-111 | Service book | Errors and Troubleshooting MN-111 ENG Rev08 | 2019/06/21 | © 2019 W&H Sterilization Srl...
Page 4: About This Manual
All drawings, images and texts contained in this manual are the property of the manufacturer. Even partial duplication of drawings, images or text is prohibited. The information contained in this document is subject to change without prior notice. MN-111 | Service book | Errors and Troubleshooting MN-111 ENG Rev08 | 2019/06/21 | © 2019 W&H Sterilization Srl...
Page 5: Conformity
Electric appliances connected to the water mains - Avoidance of backsiphonage and failure of hose-sets. Note : Every new sterilizer is delivered with a Declaration of Conformity and a Warranty Card. MN-111 | Service book | Errors and Troubleshooting MN-111 ENG Rev08 | 2019/06/21 | © 2019 W&H Sterilization Srl...
Page 6: Symbols And Messages
PROPERTY DAMAGE MESSAGES Notice: Indicates information considered important, but not hazard-related. Typically to avoid damage to the product. MN-111 | Service book | Errors and Troubleshooting MN-111 ENG Rev08 | 2019/06/21 | © 2019 W&H Sterilization Srl...
Page 7
Symbols and messages LABEL ON THE BOX MN-111 | Service book | Errors and Troubleshooting MN-111 ENG Rev08 | 2019/06/21 | © 2019 W&H Sterilization Srl...
Page 8: Safety Warnings
The transport of the sterilizer shall be done by two authorized technicians using PPE devices (personal protective equipment) according to applicable standards; The sterilizer shall be handled with care. MN-111 | Service book | Errors and Troubleshooting MN-111 ENG Rev08 | 2019/06/21 | © 2019 W&H Sterilization Srl...
Page 9: Emergency Door Opening
Insert the opening tool into the hole and then turn it counterclockwise until the door is unlocked (proceed slowly until it stops). MN-111 | Service book | Errors and Troubleshooting MN-111 ENG Rev08 | 2019/06/21 | © 2019 W&H Sterilization Srl...
Page 10: Errors
If the values are different from those measured by the sterilizer (check the System Info screen), replace the main board. Room temperature too high. Clean the component with compressed air. Condenser/Dust filter/Fan grid clogged/dirty. MN-111 | Service book | Errors and Troubleshooting MN-111 ENG Rev08 | 2019/06/21 | © 2019 W&H Sterilization Srl...
Page 11
Main board failure. If the problem persist, see error "087 to 099" above and perform the relevant test. door opening. MN-111 | Service book | Errors and Troubleshooting MN-111 ENG Rev08 | 2019/06/21 | © 2019 W&H Sterilization Srl...
Page 12
COMPONENTS. Replace the sensor if needed. Safety block during HEA2 phase. See error "164" above, all causes. (Pchamber > 1.9 barA) MN-111 | Service book | Errors and Troubleshooting MN-111 ENG Rev08 | 2019/06/21 | © 2019 W&H Sterilization Srl...
Page 13
See Test instructions service book, chapter SPECIFIC TESTS FOR INDIVIDUAL COMPONENTS, Chamber heater temperature sensor (TABLE POINT 1 and 2). If it is necessary, replace the main board. MN-111 | Service book | Errors and Troubleshooting MN-111 ENG Rev08 | 2019/06/21 | © 2019 W&H Sterilization Srl...
Page 14
HEPA filter tube line clogged/dirty. Levelling set points not achieved. Replace component if needed and/or fix the problem. F2 filter clogged/dirty MN-111 | Service book | Errors and Troubleshooting MN-111 ENG Rev08 | 2019/06/21 | © 2019 W&H Sterilization Srl...
Page 15
Fix any detected leak. H20 overconsumption during See error "422" above, all causes. HEA1 phase (starting from the beginning of the cycle H20>300cc). MN-111 | Service book | Errors and Troubleshooting MN-111 ENG Rev08 | 2019/06/21 | © 2019 W&H Sterilization Srl...
Page 16
Proceed as per errors "527 - 531" above, but only with the OPEN side microswitch. (OPEN side). Microswitch failure (OPEN side). Main board failure. Impossible position detected. See error "Errors" on page 10. MN-111 | Service book | Errors and Troubleshooting MN-111 ENG Rev08 | 2019/06/21 | © 2019 W&H Sterilization Srl...
Page 17
Upgrade the software to the latest version, if the problem persists replace the main board. Main board failure. If the problem persists, call service. MN-111 | Service book | Errors and Troubleshooting MN-111 ENG Rev08 | 2019/06/21 | © 2019 W&H Sterilization Srl...
Page 18: Other Problems
Check presence of paper. Printer fault Replace printer. Wrong printer model selected Set the right printer model. Please refer to the Instructions for use. MN-111 | Service book | Errors and Troubleshooting MN-111 ENG Rev08 | 2019/06/21 | © 2019 W&H Sterilization Srl...
Page 19: Usb Device Problems
Instructions for use. Check external filling system. Chamber not properly rinsed after cleaning Clean sterilizer chamber. Please refer to the Instructions for use. MN-111 | Service book | Errors and Troubleshooting MN-111 ENG Rev08 | 2019/06/21 | © 2019 W&H Sterilization Srl...
Page 20
Run the diagnostic cycle S. G. Perform. Test Noisy fan Condenser fan obstructed Check if cables or tubes obstruct the fan. MN-111 | Service book | Errors and Troubleshooting MN-111 ENG Rev08 | 2019/06/21 | © 2019 W&H Sterilization Srl...
Page 22
Manufacturer MN-111 W&H Sterilization Srl Service book via Bolgara, 2 Errors and Troubleshooting Brusaporto (BG) Italy Rev08 2019/06/21 www.wh.com Subject to changes med.wh.com +39 035 66 63 000...
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the MN-111 and is the answer not in the manual?
Questions and answers