Carrier 50JS Installation, Start-Up And Service Instructions Manual page 17

Single-package heat pump units
Table of Contents

Advertisement

UNIT
MOTOR SPEED
Watts
Low
Cfm
Watts
018
Med
Cfm
Watts
High
Cfm
Watts
Low
Cfm
Watts
024
Med
Cfm
Watts
High
Cfm
Watts
Low
Cfm
Watts
30
Med
Cfm
Watts
High
Cfm
Watts
Low
Cfm
Watts
36
Med
Cfm
Watts
High
Cfm
Watts
Low
Cfm
Watts
42
Med
Cfm
Watts
High
Cfm
Watts
Low
Cfm
Watts
48
Med
Cfm
Watts
High
Cfm
Watts
Low
Cfm
Watts
60
Med
Cfm
Watts
High
Cfm
* Air delivery values are based on operating voltage of 230 v or 460 v, wet coil, without filter or electric heater. Deduct filter and electric heater pressure drops to obtain
static pressure available for ducting.
NOTES:
1. Do not operate the unit at a cooling airflow that is less than 350 cfm for each 12,000 Btuh of rated cooling capacity. Evaporator coil frosting may occur at airflows below
this point.
2. Dashes indicate portions of table that are beyond the blower motor capacity or are not recommended.
3. Deduct 10% for 208v.
2. Place SYSTEM switch in COOL position and FAN switch in
AUTO position. Set control below room temperature. Observe
that cooling cycle shuts down when control setting is satisfied.
3. Place system switch in HEAT position. Set control above
room temperature. Observe that compressor, outdoor fan, and
indoor blower motors start. Observe that heating cycle shuts
down when control setting is satisfied.
4. When using an automatic changeover room thermostat, place
both SYSTEM and FAN switches in AUTO positions. Ob-
serve that unit operates in Cooling mode when temperature
control is set to ''call for Cooling'' (below room temperature),
and unit operates in Heating mode when temperature control
is set to "call for Heating" (above room temperature).
Table 4A—Wet Coil Air Delivery
Unit 50JS 018-060 (Deduct 10% for 208v)*
0.0
0.1
0.2
0.3
-
-
-
214
-
-
-
821
-
-
-
-
-
-
-
-
-
-
-
-
-
-
237
214
-
-
971
821
-
-
-
-
-
-
-
-
-
-
-
-
295
292
289
928
882
802
388
383
377
372
1203
1120
1062
1004
-
-
-
-
-
-
592
581
567
552
1499
1421
1351
1281
-
-
-
660
-
-
-
1475
-
-
-
-
-
-
606
596
586
575
1464
1399
1341
1282
680
665
649
635
1608
1535
1461
1387
768
755
742
730
1656
1576
1508
1447
741
724
709
690
1994
1937
1869
1797
-
-
-
773
-
-
-
1957
-
-
-
-
-
-
742
723
698
666
2197
2141
2103
2057
838
822
803
780
2485
2406
2269
2127
-
934
913
891
-
2483
2391
2283
EXTERNAL STATIC PRESSURE (IN. WG)
0.4
0.5
0.6
191
170
-
696
575
-
-
-
-
-
-
-
-
-
-
283
274
267
-
848
707
555
191
-
-
696
-
-
-
368
366
365
-
957
872
785
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
366
361
-
930
838
-
-
469
458
449
-
1141
1027
924
538
525
512
1207
1125
1034
636
617
603
1371
1274
1186
-
-
776
761
-
-
1452
1356
563
550
537
1218
1146
1066
622
611
600
1316
1247
1180
718
707
696
1390
1331
1268
664
631
594
1722
1645
1566
744
715
687
1867
1787
1719
-
-
799
782
-
-
1914
1842
629
591
559
1988
1894
1783
752
721
689
2012
1937
1894
866
837
806
2170
2061
1960
IMPORTANT: Three-phase, scroll compressors are direction ori-
ented. Unit must be checked to ensure proper compressor 3-phase
power lead orientation. If not corrected within 5 min., the internal
protector will shut off the compressor. The 3-phase power leads to
the unit must be reversed to correct rotation. When turning
backwards, scroll compressors emit elevated noise levels, and the
difference between compressor suction and discharge pressures
may be dramatically lower than normal.
CHECKING AND ADJUSTING REFRIGERANT CHARGE
— The refrigerant system is fully charged with R-22 refrigerant
and is tested and factory sealed.
NOTE: Adjustment of the refrigerant charge is not required
unless the unit is suspected of not having the proper R-22 charge.
17
0.7
0.8
0.9
1.0
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
360
-
-
688
-
-
425
414
-
891
735
-
-
-
-
-
-
-
-
-
-
-
-
-
442
-
-
828
-
-
499
-
-
936
-
-
592
581
566
1105
1024
928
744
725
706
689
1254
1145
1030
910
-
-
-
-
-
-
590
-
-
1111
-
-
684
671
-
1198
1119
-
562
543
552
1480
1384
1269
662
640
625
1653
1575
1463
773
756
704
1774
1686
1538
540
-
-
1674
-
-
661
639
632
1855
1770
1571
776
750
735
1868
1780
1687
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-