Pre-installation Guide PlateWriter Infuse IMPORTANT! Please keep this manual with other equipment documentation for future reference. August 9th, 2021 Edition AA, Part No 10105529 English (en-us) Original version...
General information General information About this manual This manual applies to the PlateWriter Infuse . This manual is valid for serial nos: PlateWriter Infuse 10102450 - 0001 10103500 - 0001 The PlateWriter Infuse is manufactured by: Glunz & Jensen s.r.o. Kosicka 50 080 01 Presov Slovakia Always read the Safety Instruction Manual part No 21741 before installing, servicing, or operating the...
Page 3
General information Reservations • This manual was written and illustrated using the best possible information available at the time of publication. • Any differences between this manual and the PlateWriter Infuse reflect improvements introduced after the publication of the manual. •...
Page 4
General information • It is the responsibility of the owner and operator(s) of the PlateWriter Infuse that the installation is made in accordance with local regulations, and by engineers authorized to carry out plumbing and electrical installations. • The manufacturer cannot be held responsible for any damage caused by incorrect installation of the PlateWriter Infuse.
Page 5
When the crate arrives When the crate arrives Storing the crates The crates containing the PlateWriter system will usually arrive some time before the arrival of the Service Technician. In such a case you should prepare an appropriate place indoors to store the crates. Crate dimensions and weights Below are the dimensions and weights of the crates included with the delivery: L x W x H...
Page 6
When the crate arrives Transporting the crates Handling the crates The icons on the crates indicate how to handle them during transport and storage: Lifting the crates To lift the crates, at least a fork-lift truck or two persons and a hand-powered pallet mover are required. Available doorway width for transport If the width of the door(s) through which the crates have to be transported to the installation site are too narrow, you will have to unpack the crates and transportall parts to the installation site separately.
Site requirements Site requirements General requirements Environmental requirements Provide a heating and ventilating system capable of maintaining room temperature between 20 and 24°C (68 and 75°F) and relative humidity between 40 and 80%. For heat emission see “Power consumption” on the page 11. Cleaning facilities We recommend that you have easy access to a sink and a water tap with hot water for cleaning purposes.
Site requirements Space requirements PlateWriter dimensions Pre-installation Guide PlateWriter Infuse August, 2021...
Page 9
Site requirements Free space around the PlateWriter Decide where to place the unit and make sure that the free space around it makes operation and servicing possible. Be aware of the following: • Liquid Dot cartridges need to be replaced on each side of the unit. •...
Site requirements RIP workstation L ocation The RIP workstation is placed in the bracket under the input table from the imaging unit and need to be connected using the enclosed USB-cable. Network connection If the RIP workstation is going to be connected to a local network (LAN) make sure to provide a network connection nearby.
Site requirements Power outlet requirements If not already present, main power outlets should be installed in the room where the unit will be situated. Max. distance to the machine 2m (6ft.). WARNING: The units are Class 1 appliances and must be connected to earthed mains socket outlets.
Site requirements Power cables NOTE: The equipment is delivered with the power cables required for the installation (USA only, outside USA these must be ordered separately). If, for some reason, you decide to use cables others than those supplied, make sure that they conform to the directions given below.
Page 13
Site requirements Finishing unit (USA) Appliance coupler 16A (IEC 60320) Plug type NEMA L6-15P, 230V AC, 15A Cable min.3x18AWG, type SJT or harder service Finishing unit (Rest of world) NOTE: A connector plug only included with the maintenance kit when the country of installation is specified upon order.
Pre-installation checklist Pre-installation checklist Please ask the customer to answer the following questions in order to ensure a trouble-free installation of the processor: Delivery of the crate and transport to the installation site A. Is there a place indoors where the crates box can be stored temporarily? B.
Page 15
Pre-installation checklist Disposition of the various supplies and equipment on the installation site: August, 2021 Pre-installation Guide PlateWriter Infuse...