VII- Scan Profiles

Scan Profile
A
is a collection of hardware settings which control the electrical signals applied to the IC under test during the
scan. These include voltage, frequency, waveform and source resistance. Each profile has a name which loosely describes the
type of components that could be tested with this profile.
However, the SENTRY software provides an automatic setting which uses an optimised
components to be tested. This setting is strongly recommended. The AUTOMATIC scan profile uses both the High Sensitivity
and High Speed profiles successively, therefore generating two PinPrints per pin for increased test coverage.
Scan Profile Manager
The
for adding and modifying
Scan Profiles
for the majority of components, but can be used for specialist applications by suitably qualified operators. You cannot change
Scan Profile
the
without the hardware connected and turned on.
Some of the features provided in this section include :
The
Add
button. Clicking this button allows you to add a profile to the library. See section 0 for more information.
Copy
The
button. This button allows you to add a copy of the selected profile to the library - see section 0 for more
information. Note this button is only enabled if a profile is selected in the profile list (Error! Reference source not
found.).
Delete
The
button. This button allows you to remove a profile from the library. Note this button is only enabled if a
profile is selected in the profile list.
Hardware
The
status. Shows the current status of the connected hardware.
Profile Name
The
The
Base Voltage Range
conjunction with the peak voltages (see below) during the scan.
The
Low Peak Voltage
the selected base voltage range.
High Peak Voltage
The
value of the selected base voltage range.
Waveform
The
: This is the waveform used during the scan. We recommend using only sine waves for this setting.
The
Source resistance
1k, 10k and 100k are available, but we recommend using 1k or 10k for best results particularly when performing
comparisons.
Frequency
The
: This is the frequency of the signal used for the scan, and can be set from 100Hz to 5kHz in a 1-2-5
sequence. For the most accurate results, use the lowest frequency, but you can increase scan times by using a higher
frequency on higher pin count devices at the expense of a loss of comparison accuracy.
Copyright © 2012 - 2017 ABI Electronics Ltd
Learn New Device
(available from the
to suit your application. This is an advanced function which does not need to be used
. The user defined name for this profile.
: This is controlled by the SENTRY hardware, and is a symmetrical voltage range used in
. This is the lowest voltage used during the scan. It cannot be lower than the lowest value of
. This is the highest voltage used during the scan. It cannot be higher than the highest
: This is the source resistance through which the scan voltage is applied to the IC. Values of
Scan Profile
Learn
window in the
section) provides editing facilities
for most electronics