Boiler; Coding - Viessmann Vitoladens 300-W Installation And Service Instructions Manual

Table of Contents

Advertisement

Code 2

Boiler

Coding

Coding in the delivered condition
04:1
Minimum burner pause time sub-
ject to the boiler load (specified by
boiler coding card)
06:...
Maximum limit of the boiler water
temperature, specified by boiler
coding card in °C
0d:0
Never adjust
0E:0
Never adjust
21:0
No service interval set (in hours
run)
23:0
No time set for burner service in-
terval
24:0
"Service" not shown on the dis-
play
26:0
Burner fuel consumption (stage 1).
No metering if code "26:0" is pro-
grammed.
29:0
Burner fuel consumption (stage 1
and 2). No metering if code "29:0"
is programmed
2E:0
Never adjust
2F:0
Venting program/filling program
disabled
30:1
Internal variable speed circulation
pump (set automatically)
31:...
Set speed of the internal circula-
tion pump when operated as boiler
circuit pump in %, specified by the
boiler coding card
38:0
Burner control unit status: opera-
tional (no fault)
56
Possible change
04:0
Minimum burner pause time set per-
manently (specified by boiler coding
card)
06:20
Maximum limit of boiler water tem-
to
perature within the ranges specified
06:127
by the boiler
21:1
The number of hours run before the
to
burner should be serviced is adjust-
21:100
able from 100 to 10,000 h
One adjusting step
23:1
Time interval adjustable from 1 to
to
24 months
23:24
24:1
"Service" shown on the display.
The address is set automatically and
must be reset manually after a serv-
ice.
26:1
Input from 0.1 to 25.5
to
1 step
26:255
29:1
Input from 0.1 to 25.5
to
1 step
29:255
2F:1
Venting program enabled
2F:2
Filling program enabled
30:0
Internal circulation pump not speed-
controlled (e.g. temporarily for serv-
ice)
31:0
Set speed adjustable from 0 to
to
100 %
31:100
38:≠0
Burner control unit status: fault
100 h
0.1 l or gallon / hour
0.1 l or gallon / hour