Download Print this page

Vision ZP3113IN-7 Installation & Operation Manual

4-in-1 motion sensor, temp./humidity/light sensor built-in

Advertisement

Quick Links

Introduction
Thanks for choosing the Vision's wireless 4-in-1 Motion sensor of the
home security device. The new multi-sensor consists of motion,
temperature, humidity & light sensor for combing several functionality in
one device; more attractive and economic consideration. This sensor is
a Z-Wave
enabled device (interoperable, two-way RF mesh
TM
networking technology) and is fully compatible with any Z-Wave
it's security framework. Every mains powered Z-Wave
repeater and multiple devices result in more possible transmission routes which helps
eliminate "RF dead-spots".
Z-Wave
enabled device displaying the Z-Wave
TM
regardless of the manufacturer, and ours can also be used in other manufacturer's
Z-Wave
enabled networks. This sensor monitors movement, and send Z-Wave
TM
signal when movement is detected inside the building. With Temperature, Humidity &
Light sensor built inside, it will send the signal out when temperature, humidity & Lightness
changed. When the device is secure included into Z-Wave network, above communica-
tion will be encrypted.
Product Description and Specification
Specification:
Protocol: Z-Wave™ (ZGM130S)
Frequency Range:
865.22MHz (ZP3113IN-7)
868.42MHz (ZP3113EU-7)
869.00MHz (ZP3113RU-7)
908.42MHz (ZP3113US-7)
916.00MHz (ZP3113IL-7)
919.80MHz (ZP3113HK-7)
921.42MHz (ZP3113BR-7)
920.00MHz~923.00MHz (ZP3113TH-7)
920.00MHz~923.00MHz (ZP3113KR-7)
922.00MHz~926.00MHz (ZP3113JP-7)
Operating Range: Up to 100 feet line of sight
Operating Temp.: -10°C~ 40°C (5°F~104°F)
Command Class
COMMAND CLASS NAME
ASSOCIATION
ASSOCIATION GROUP INFO
BATTERY
CONFIGURATION
DEVICE RESET LOCALLY
FIRMWARE UPDATE
INDICATOR
MANUFACTURER SPECIFIC
MULTI CHANNEL ASSOCIATION
MULTILEVEL SENSOR
NOTIFICATION
POWERLEVEL
VERSION
WAKE_UP
APPLICATION STATUS
SECURITY
SECURITY_2
SUPERVISION
TRANSPORT_SERVICE
ZWAVEPLUS_INFO
Limited Warranty
Vision Guarantees that every wireless PIR sensor is free from physical defects in material
and workmanship under normal use for one year from the date of purchase. If the product
proves defective during this one-year warranty period, Vision will replace it free of charge.
Vision does not issue any refunds. This warranty is extended to the original end user
purchase only and is not transferable. This warranty does not apply to : (1) damage to
units caused by accident, dropping or abuse in handling, or any negligent use; (2) units
which have been subject to unauthorized repair, taken apart, or otherwise modified; (3)
units not used in accordance with instruction; (4) damages exceeding the cost of the
product; (5) transit damage, initial installation costs, removal cost, or reinstallation cost.
For information on additional devices, please visit us at
www.visionsecurity.com.tw
Federal Communications Commission Statement
FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) This device
must accept any interference received, including interference that may cause undesired
operation.
FCC Caution
To assure continued compliance, any changes or modifications not expressly
approved by the party responsible for compliance may void the user's
authority to operate his equipment. (Example – use only shielded interface
cables when connecting to computer or peripheral devices)
FCC Statement in User's Manual (for class B) FCC Section 15.105 "Federal Communi-
cations Commission (FCC) Statement"
This equipment has been tested and found to comply with the limits for a class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
enabled network and
TM
enabled device acts as a signal
TM
logo can also be used with it
TM
Package Content
1pc ZP 3113 Multi-Sensor
1pc Adhesive tape for sensor
1pc CR123A Lithium Battery
1pc Installation & Operation Manual
VERSION
REQUIRED SECURITY CLASS
2
S2 or S0
3
S2 or S0
1
S2 or S0
4
S2 or S0
1
S2 or S0
5
S2 or S0
3
S2 or S0
2
S2 or S0
3
S2 or S0
11
S2 or S0
8
S2 or S0
1
S2 or S0
3
S2 or S0
2
S2 or S0
1
None
1
None
1
None
1
None
2
None
2
None
ZP3113-7
V0
1090910
TM
Installation & Operation Manual
4-in-1 Motion Sensor
(Temp./Humidity/Light Sensor Built-In)
Configuration
This ZP3113-7 supports change capabilities by Configuration Command Class
1
after receiving the wake up notification, but, no support this change on the
power-on report's wake up notification, because the other devices are not ready
so quickly.
The controller has to rediscover the product's capabilities after altering
2
capabilities.
The controllers has to re-include the node in the network if the controller does not
3
have any capability rediscovery option.
Configuration – Temperature
Size
Parameter 1
1
Parameter 2
1
Configuration – Humidity
Size
Parameter 3
1
Configuration – Light
Size
Parameter 4
1
Configuration – Motion Sensor
Size
Parameter 5
1
Parameter 6
1
Configuration – LED Mode
Size
Parameter 7
1
Configuration – Acknowledge:
Size
Parameter 8
1
Z P 3 11 3 I N - 7
ZP3113EU-7
ZP3113RU-7
ZP3113US-7
ZP3113BR-7
Z P 3 11 3 I L - 7
ZP3113HK-7
ZP3113TH-7
ZP3113KR-7
ZP3113JP-7
www.visionsecurity.com.tw
VALUE
°C
0x00
°F
0x01
1~50 (Set up from 0.1°C~5°C)
(Parameter 1)
Choose the temperature scale (°C or °F)
(Parameter 2)
Temperature difference X °C to auto report (every 5 minutes detect)
VALUE
0,5~50 (Set up from 0 for Off or 5%~50%)
11 ~ 7 levels sensitivity, (default: 4)
(Parameter 3)
Humidity difference X % to auto report (every 5 minutes detect)
VALUE
0,5~50 (Set up from 0 for Off or 5%~50%)
(Parameter 4)
Light difference X % to auto report (every 5 minutes detect).
VALUE
1 ~ 127 (unsigned decimal) Minutes (default: 3 minutes)
1 ~ 7 levels sensitivity, (default: 4)
(Parameter 5)
Re-trigger
duration: User can change value from 1 to 127
minutes to setup the re-trigger time when there is no movement
detected in the period of time. Default is 3 minutes.
(Parameter 6)
Infrared sensor sensitivity
adjustment, 7 levels sensitivity,
1 = most sensitive, 7 = most insensitive, default values= 4
VALUE (Default: Mode 1)
11 ~ 3 (Mode 1 ~ Mode 3)
Mode 1
LED Turn Off (Both Temp/PIR Trigger)
Mode 2
LED Quick Flash (Temp. / PIR Trigger)
Mode 3
PIR Trigger (Quick Flash) Temp. Trigger (LED Off)
(Parameter 7)
Define the LED's working method.
VALUE
0 ~ 10 (unsigned decimal) Times (default: 3 Times)
(Parameter 8)
PIR Trigger Notification Re-sending Times:
prevent any gateway lost, user can change the value from 0 to
10 times to setup the notification re-sending times in case there
is no ack from the gateway after sending the PIR Trigger
Notification. Default is 3 Times.
Default
°C (0X00)
3 (°C)
Default
20%
Default
25%
In order to

Advertisement

loading

Summary of Contents for Vision ZP3113IN-7

  • Page 1 Vision will replace it free of charge. so quickly. Vision does not issue any refunds. This warranty is extended to the original end user The controller has to rediscover the product’s capabilities after altering purchase only and is not transferable.
  • Page 2 Operation Using adhesive tape to mount ZP3113 at 2 meters above surface. To enhance Support OTA Firmware update from controller. Please refer to your controller proper operation, place ZP3113 on the location which can detect the room manual. use COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5. To widely.

This manual is also suitable for:

Zp3113eu-7Zp3113ru-7Zp3113us-7Zp3113br-7Zp3113il-7Zp3113hk-7 ... Show all