Download Print this page
Honeywell Home SiX Series Installation Instructions

Honeywell Home SiX Series Installation Instructions

Advertisement

Quick Links

SiXGB
The SiXGB is a wireless glassbreak detector intended for use with Honeywell Home controls that support SiX™ Series
devices.
Mounting Guidelines
The SiXGB can be mounted on the
wall or on the ceiling:
• within 7.6 m (25 feet) of the
protected glass
• within clear view of the protected
glass
• at least 2 m (6.5 feet) from the floor
• at least 1 m (3.3 feet) from forced
air ducts
• at least 1 m (3.3 feet) from sirens or
bells greater than 5 cm (2 inches) in
diameter
• between the protected glass and
any heavy window coverings
• when heavy window coverings are
present, the detector can be
mounted on the window frame
• Avoid mounting the detector on the
same wall as the protected glass,
on free-standing posts or pillars, or
in rooms with noisy equipment (air
compressors, bells, power tools,
etc.), if this equipment is operated
when the detector is armed.
To remove the mounting bracket:
Turn the top of the detector 15 degrees counter-
clockwise and separate the mounting bracket.
NOTE: Before mounting the device permanently,
conduct Go/No Go tests (see controller's
instructions) to verify adequate signal strength and
adjust the device location and orientation as
necessary.
The rear tamper plate MUST be mounted to a stud,
solid wood, or with a robust wall anchor.
Installation Instructions

Advertisement

loading
Need help?

Need help?

Do you have a question about the SiX Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Honeywell Home SiX Series

  • Page 1 SiXGB Installation Instructions The SiXGB is a wireless glassbreak detector intended for use with Honeywell Home controls that support SiX™ Series devices. Mounting Guidelines The SiXGB can be mounted on the wall or on the ceiling: • within 7.6 m (25 feet) of the protected glass •...
  • Page 2 Enroll Set the controller in Programming Mode and when prompted: 1. Remove the battery tab to activate the device and begin the enrollment process. 2. The Green [G1] LED flashes during enrollment (up to about 20 seconds*) The device sends its unique MAC ID (Serial Number) and Services information to the controller.
  • Page 3 SiXGB LEDs The detector has three LEDs which are visible when the unit is mounted. Green 1 [G1] LED indicates device enrollment and tamper status. The Red [R] and Green 2 [G2] LEDs provide information on detector status during Test Mode. The Green 2 LED indicates events and the Red LED indicates Alarms.
  • Page 4 For patent information, see www.resideo.com 2 Corporate Center Drive, Suite 100 The Honeywell Home Trademark is used under license from P.O. Box 9040, Melville, NY 11747 Honeywell International Inc. All other trademarks are the properties of their respective owners.

This manual is also suitable for:

Sixgb