Tecnosystemi Apply.co AirPur3 Plus 160 User Manual

Tecnosystemi Apply.co AirPur3 Plus 160 User Manual

Built-in and wall-mounted heat recovery unit
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

COD. C20002850
REV. 04 / 11-06-2019
MANUALE D'USO
RECUPERATORE DI CALORE STATICO
A FLUSSI INCROCIATI AD INCASSO E A PARETE
COD. ACD100031 - ACD100032 - ACD100033
ACD100034 - ACD100035 - ACD100036
MODELLO AD INCASSO
MODELLO A PARETE
Sistemi
Tecnosystemi S.p.A.
via dell'Industria, 2/4 - Z.I. San Giacomo di Veglia
31029 Vittorio Veneto (Treviso) - Italia
Tel +39 0438.500044 - Fax +39 0438.501516
Numero Verde 800 904474
email: info@tecnosystemi.com
www.tecnosystemi.com
C.F. - P. IVA - R.I.TV IT02535780247 Cap. Soc. € 5.000.000,00 i.v.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Apply.co AirPur3 Plus 160 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Tecnosystemi Apply.co AirPur3 Plus 160

  • Page 1 ACD100034 - ACD100035 - ACD100036 MODELLO AD INCASSO MODELLO A PARETE Sistemi Tecnosystemi S.p.A. via dell’Industria, 2/4 - Z.I. San Giacomo di Veglia 31029 Vittorio Veneto (Treviso) - Italia Tel +39 0438.500044 - Fax +39 0438.501516 Numero Verde 800 904474 email: info@tecnosystemi.com...
  • Page 2: Requisiti Di Sicurezza

    Sistemi INTRODUZIONE Il presente manuale include la descrizione tecnica, il funzionamento, installazione e istruzioni di montaggio, dati tecnici per l’aspiratore estrattore con rigenerazione di energia “AIR PUR 3 PLUS”, nel seguito denominato recuperatore. REQUISITI DI SICUREZZA Leggere il manuale dell ‘utente con attenzione prima dell’utilizzo e dell’installazione del recuperatore reversibile a camera singola con rigenerazione di energia.
  • Page 3 Sistemi PRECAUZIONI DI MONTAGGIO Il recuperatore non deve essere Il recuperatore deve essere utilizzato al di fuori della gamma di scollegato dalla rete elettrica prima temperatura indicata nel manuale d’uso o in atmosfere aggressive o a rischio di di ogni installazione o riparazione esplosione.
  • Page 4 Sistemi CARATTERISTICHE TECNICHE MODELLO AD INCASSO DIMENSIONI (mm) MODELLI 160 / 230 / 300 220/400 ALTEZZA GRIGLIA INTERNA ALTEZZA GRIGLIA ESTERNA SCATOLA RECUPERATORE CODICE ACD100031 ACD100032 ACD100033 MODELLO ALIMENTAZIONE 230 V 230 V 230 V FREQUENZA 50 Hz 50 Hz 50 Hz POTENZA MASSIMA 30 W...
  • Page 5 Sistemi CARATTERISTICHE TECNICHE MODELLO A PARETE DIMENSIONI (mm) MODELLI 160 / 230 / 300 ALTEZZA GRIGLIA INTERNA ALTEZZA GRIGLIA ESTERNA SCATOLA RECUPERATORE CODICE ACD100034 ACD100035 ACD100036 MODELLO ALIMENTAZIONE 230 V 230 V 230 V FREQUENZA 50 Hz 50 Hz 50 Hz POTENZA MASSIMA 30 W 70 W...
  • Page 6 Sistemi FUNZIONAMENTO DEI RECUPERATORI MOD. “AIR PUR 3 PLUS” I recuperatori di calore Tecnosystemi nelle tre versioni 160 / 230 / 300, sono impiegati per la areazione bilanciata di attività commerciali (negozi, ristoranti ecc.), residenziali e comunque adattabili a tutti quegli ambienti ove sia necessario avere un ricambio d’aria, evitando però la dispersione della temperatura interna.
  • Page 7 Sistemi TELECOMANDO Il recuperatore è comandato da un telecomando fornito in dotazione. Impostazione valore di umidità RESET MANUTENZIONE Ventilatore ON FILTRI TENERE PREMUTO Cambio Velocità PER 3 SECONDI Ventilatore Velocità massima (Valore umidità 60%) Velocità media (Valore umidità 50%) Velocità minima (Valore umidità...
  • Page 8 Sistemi IMPOSTAZIONE DEL VALORE DI UMIDITÀ Per impostare il valore di umidità desiderato (40%, 50% o 60%) procedere nel modo seguente: • Selezionare, tramite il telecomando, la modalità AUTO 1 (led giallo) o AUTO 2 (led bianco). • Premere il tasto “ON”. •...
  • Page 9 Sistemi FUNZIONI TELECOMANDO 1. Accensione - On / accensione dell’apparecchio - Impostazione del valore di umidità’ 2. Spegnimento - Off / spegnimento apparecchio - Reset allarme pulizia filtro 3. Impostazione di velocità Velocità minima / Valore umidità 40% Velocità media / Valore umidità 50% Velocità...
  • Page 10: Avvertenze Per Il Montaggio

    Sistemi AVVERTENZE PER IL MONTAGGIO ATTENZIONE! IL RECUPERATORE NON DEVE ESSERE INSTALLATO IN LUOGHI DOVE IL CONDOTTO ARIA POSSA ESSERE BLOCCATO DA TAPPARELLE, TENDE, ECC. PER IMPEDIRE IL DEPOSITO E L’ACCUMULO DI POLVERE. INOLTRE LE TENDE POTREBBERO OSTRUIRE IL NORMALE FLUSSO D’ARIA NELLA STANZA, RENDENDO INEFFICACE IL FUNZIONAMENTO DEL RECUPERATORE.
  • Page 11: Manutenzione

    Sistemi Aperto l’imballo della macchina smontate la griglia interna del recuperatore e togliere il pacco di scambio per agevolare l’operazione di installazione. Dividere il corpo recuperatore dalla scocca. Il corpo recuperatore va fissato alla muratura utilizzando il fissaggio idoneo in relazione alla tipologia di muratura.
  • Page 12 Sistemi IMPORTANTE! Al termine del suo utilizzo l’apparecchiatura va smaltita secondo le attuali norme e leggi vigenti. Manutenzione rigeneratore e filtro (ogni 1500 ore). Togliere il filtro davanti al rigeneratore. Tirare il cordino del rigeneratore per togliere il rigeneratore dal condotto aria.
  • Page 13: Ricerca Guasti

    Sistemi RICERCA GUASTI Problematica Possibili cause Gestione dei guasti Controllare che il recuperatore sia collegato correttamente Alimentazione mancante. all’alimentazione di rete ed apportare eventuali correzioni se La ventola non parte necessario all’accensione del Spegnere il recuperatore. recuperatore. Risolvere il blocco motore e Il motore è...
  • Page 14 Sistemi NOTE...
  • Page 15 Air Conditioning Accessories Multi - Zone Air Control System Tecnosystemi S.p.A. via dell’Industria, 2/4 - Z.I. San Giacomo di Veglia 31029 Vittorio Veneto (Treviso) - Italia Tel +39 0438.500044 - Fax +39 0438.501516 Numero Verde 800 904474 (only for Italy) Instruments &...
  • Page 16: Safety Requirements

    Multi - Zone Air Control System INTRODUCTION Instruments & Ventilation Tools Solutions This manual includes the technical description, operation, installation and assembly instructions, technical data for the intake extractor unit with energy regeneration “AIR PUR 3 PLUS”, hereinafter referred to as recovery unit. Accessories For Heating SAFETY REQUIREMENTS...
  • Page 17: Assembly Warnings

    Multi - Zone Air Control System ASSEMBLY WARNINGS Instruments & Ventilation Tools Solutions The recovery unit must not be used The recovery unit must be outside the temperature range, disconnected from the mains indicated in the user manual, supply before carrying out any or in aggressive or explosive Accessories installation or repair operation.
  • Page 18 Multi - Zone Air Control System TECHNICAL FEATURES BUILT-IN MODEL Instruments & Ventilation Tools Solutions DIMENSIONS (mm) MODEL 160 / 230 / 300 Accessories For Heating 220/400 INTERNAL GRID HEIGHT EXTERNAL GRID HEIGHT HEAT RECOVERY UNIT CODE ACD100031 ACD100032 ACD100033 MODEL SUPPLY VOLTAGE 230 V...
  • Page 19 Multi - Zone Air Control System TECHNICAL FEATURES WALL-MOUNTED MODEL Instruments & Ventilation Tools Solutions DIMENSIONS (mm) MODEL 160 / 230 / 300 Accessories For Heating INTERNAL GRID HEIGHT EXTERNAL GRID HEIGHT HEAT RECOVERY UNIT CODE ACD100034 ACD100035 ACD100036 MODEL SUPPLY VOLTAGE 230 V 230 V...
  • Page 20 Tools Solutions The Tecnosystemi heat recovery units in the three versions 160 / 230 / 300, are used to balance ventilation in commercial establishments (shops, restaurants, etc.) as well as in residential environments but they are, in any case, perfectly adaptable to any location where air needs to be Accessories refreshed but without, however, dispersing the interior temperature.
  • Page 21: Remote Control

    Multi - Zone Air Control System REMOTE CONTROL Instruments & Ventilation Tools Solutions REMOTE CONTROL DEVICE INCLUDED Accessories For Heating Humidity value setting RESET FILTER MAINTENANCE Fan ON Press and hold for 3 seconds Change speed Fan OFF Maximum speed (Humidity value 60%) Medium speed (Humidity value 50%)
  • Page 22 Multi - Zone Air Control System SETTING THE HUMIDITY VALUE Instruments & Ventilation Tools Solutions To set the value of the desired humidity (40%, 50% or 60%) proceed as follows: • Using remote control, select AUTO 1 mode 1 (yellow LED) or AUTO 2 (white Accessories LED).
  • Page 23 Multi - Zone Air Control System REMOTE CONTROL Instruments & Ventilation Tools Solutions 1. ON Fan ON Accessories Humidity value setting For Heating 2. OFF Fan OFF Reset filter maintenance 3. Change speed Low speed (Humidity value 40%) Medium speed (Humidity value 50%) Maximum speed (Humidity value 60%)
  • Page 24 Multi - Zone Air Control System WARNINGS FOR THE ASSEMBLY Instruments & Ventilation Tools Solutions WARNING! THE RECOVERY UNIT SHOULD NOT BE INSTALLED IN PLACES WHERE THE AIR DUCT MIGHT BE BLOCKED BY Accessories BLINDS AND SHUTTERS, ETC. IN ORDER TO PREVENT For Heating THE ACCUMULATION OR DEPOSIT OF DUST.
  • Page 25: Maintenance

    Multi - Zone Air Control System remove the exchange package in order to proceed with the installation operation. Separate the recovery unit from the body. Instruments & Ventilation The recovery unit body is to be fixed to the wall using a fixing suitable for the type of wall. Tools Solutions Cut the plastic tubes according to the thickness of the wall.
  • Page 26 Multi - Zone Air Control System IMPORTANTE! Instruments & Ventilation At the end of its use, the appliance should be disposed, according to current regulations Tools Solutions and laws. Maintenance of the regenerator and of the filter Accessories For Heating (every 1,500 hours).
  • Page 27: Troubleshooting

    Multi - Zone Air Control System TROUBLESHOOTING Instruments & Ventilation Tools Solutions Possible causes Management of faults Accessories Check that the recovery unit For Heating is correctly connected to the No power supply. mains supply and connect it, if necessary. The fan does not start when the recovery unit is turned on.
  • Page 28: Garanzia / Warranty

    To highlight the requirement to dispose of household electrical items separately, there is a crossed-out waste paper basket symbol on the product. Tecnosystemi S.p.A. via dell’Industria, 2/4 - Z.I. San Giacomo di Veglia 31029 Vittorio Veneto (Treviso) - Italia Tel +39 0438.500044 - Fax +39 0438.501516...

This manual is also suitable for:

Apply.co airpur3 plus 230Apply.co airpur3 plus 300Acd100031Acd100032Acd100033Acd100034 ... Show all

Table of Contents