Art.280N1 Telephone Interface Unit
Description The 280 telephone interface allows a conventional telephone to be
connected to a Videx door entry system. The telephone can be either tone or pulse
dial. The unit also incorporates the facility to divert a door panel call to a pre-
programmed telephone number.
Important installation notes:-
1. A maximum of two telephones can be connected to the output of the
Art280.
2. Only one master socket should be connected to the output of the Art280.
3. Any other telecom equipment such as Sky, Red care, Faxes, modems
should be connected before the Art280.
4. When using the Art280N1 in divert mode the speech volume levels will be
lower than when used in normal mode. This is normal and is caused by a
10dB difference from the telephone exchange.
5. If the microphone volume at the door station is adjusted too high, it could
prevent the DTMF tones from being used to open the door or trigger any
of the other special features. The same problem could occur if there is
excessive back ground noise at the door station.
6. Telephone line or mains interference can cause problems for the
Artr280N1 to identify DTMF tones.
Connections to the telephone line Each telephone line coming into your home or
office must be fitted with a six pin primary socket installed by the PTO (Public
Telecommunication Operator). It is illegal to tamper in any way with this primary
socket and you can not install it yourself. Additional connections to the primary
socket must be carried out using a BT style plug (You cannot connect directly to the
terminals inside). The ART280 telephone interface unit is supplied with a BT style
plug. For more information, see relevant paper work supplied with extension sockets.
Using a conventional telephone it is possible to do the following :
• Make and receive outside calls. (Normal Ring)
• Receive calls from the door station. (Quick double ring)
• Open the door.
• Open the speech lines to the door.
• Place a call on hold while another call is answered.
• Activate an auxiliary output for 1 second [Aux1]. This is an open collector output.
(Can be used for a number of different aux. Equipment such as opening an
additional gate or door).
• Another open collector output [Aux] will activate throughout the conversation.
(Can be used to switch a camera on etc.)
• Divert a call to a pre-programmed telephone number.
• Dial into the art280 from a remote telephone.
25/06/2002
PAGE 1 of 8
VERSION 1.6
280InstN2.

Advertisement

loading

Summary of Contents for Videx 280N1

  • Page 1 Description The 280 telephone interface allows a conventional telephone to be connected to a Videx door entry system. The telephone can be either tone or pulse dial. The unit also incorporates the facility to divert a door panel call to a pre- programmed telephone number.
  • Page 2 VIDEX ART.280N1 USER INSTRUCTIONS Wiring The wiring diagram is attached to this document and must be adhered to. Also see a number of example installations types in the back of this manual. Terminals The terminals on the Art280 each have the following functions :- Terminals L1 &...
  • Page 3 VIDEX ART.280N1 USER INSTRUCTIONS will ring for 5 double rings]. (A confirmation tone will be heard from the earpiece for each digit pressed). To program the door open time : (From 2 – 18 seconds) Pick up the handset and press RECALL + RECALL + 2 + n (Time = 2 x n) [i.e. If n = 3, the door will open for 6 seconds].
  • Page 4 VIDEX ART.280N1 USER INSTRUCTIONS Pick up the telephone and press RECALL + RECALL + 5 + 3 (A confirmation tone will be heard from the earpiece). Mode 3 is now set. MODE 2 (For telephones with flash button facility [Pulse or tone].
  • Page 5 VIDEX ART.280N1 USER INSTRUCTIONS you take the call from the door panel. To do this simply press the ‘*’ key. After the call, to switch back, simply press the ‘*’ key again or hang up. If after hanging up, there is still a call on the system. The telephone will ring again.
  • Page 6 VIDEX ART.280N1 USER INSTRUCTIONS 0.1uF capacitor 12V AC LOCK RELEASE DIODE 1N4002 12V DC LOCK RELEASE Cable size and type : When running cables for any intercom system, these cables must be installed separately from the mains cables. All multipair cables should be to CW1308 specification.
  • Page 7: Specification

    VIDEX ART.280N1 USER INSTRUCTIONS 157.5mm 65mm ART280 105mm TELEPHONE INTERFACE APPROVAL The equipment has been approved in accordance with Council Decision 98/482/EC for pan-European single terminal connection to the public switch telephone network (PSTN). However, due to differences between the individual PSTNs provided in different countries, the approval does not, of itself, give an unconditional assurance of successful operation on every PSTN network termination point.
  • Page 8 In the event of problems occurring during the installation of the Art280 telephone interface please check this troubleshooting guide before calling the Videx technical help on 0191 224 3174. Telephone does not ring but if it is picked up during a call there is speech to the door :- Option 1 : The REN value has been exceeded.