Disassembly and Reassembly
No
Parts
5
Drain Pump
&
Hose
6
Evap.
Temperature
Sensor
3-24
Procedure
1) Remove the 2 fixed screws and disconnect
the white drainage hose from the Drain
Pump. (Use +Screw Driver)
2) Remove the 2 screws and take the Drain-
Hose out from the indoor unit to disas-
semble the transparent Drain-Hose
fixed on the side of the indoor unit.
(Use +Screw Driver)
1) Use your hand to remove the temperature
sensor attached to the Evap Pipe along
with the fixing clip.