Power ON for use without Audible Alarm
1. Press and hold the power button (5) for at least 3 seconds. The red LED will flash quickly once and then the steady green
LED light will appear near the tip of the sensor (6).
2. The unit is now ready for operation without audible feedback.
Taking Measurements
1. Please test on a known live circuit to verify proper functionality first.
2. Touch the probe tip (7) to the hot conductor or insert into the hot side of the electrical outlet.
3. If AC voltage is present, the detector cone will illuminate (6) and the detector will beep. The stronger the voltage, the faster
the audible and visual alarming.
Switching the unit OFF
Press and hold the power button (5) for 2 seconds. The unit will emit a long audible tone and the LEDs will switch off. The unit
also switches OFF automatically after 5 minutes of non-use.
Important note on the meter's sensitivity
This detector is designed with high sensitivity. Static electricity or other sources of energy may randomly trip the sensor. This
is normal operation.
Flashlight Function
The ON/OFF button (2) controls the flashlight (1).
BATTERY INSTALLATION
1. Remove the end cap by gently lifting the pocket clip (4) to release the catch.
2. Insert two AAA batteries (observe polarity).
3. Replace the end cap
NOTE: If the meter does not work properly, check the batteries to make sure that they are still good and that they are
properly inserted.
The end user is legally bound (Battery ordinance) to return all used batteries and accumulators; disposal in the
household garbage is prohibited!
Deposit used batteries / accumulators at the appropriate collection points or wherever batteries / accumulators
are sold!
Disposal: Follow the valid legal stipulations with respect to the disposal of the device at the end of its lifecycle.
Two-year Warranty
Teledyne FLIR LLC warrants this Extech brand instrument to be free of defects in parts and workmanship for two years from
date of shipment (a six-month limited warranty applies to sensors and cables). To view the full warranty text please visit:
http://www.extech.com/support/warranties.
Calibration and Repair Services
Teledyne FLIR LLC offers calibration and repair services for the Extech brand products we sell. We offer NIST traceable
calibration for most of our products. Contact us for information on calibration and repair availability, refer to the contact
information below. Annual calibrations should be performed to verify meter performance and accuracy. Product specifications
are subject to change without notice. Please visit our website for the most up-to-date product information: www.extech.com.
Contact Customer Support
Customer Support Telephone List:
Calibration, Repair, and Returns:
Technical Support:
https://support.flir.com
All rights reserved including the right of reproduction in whole or in part in any form
https://support.flir.com/contact
repair@extech.com
Copyright © 2021 Teledyne FLIR LLC
www.extech.com
DV26-en-US_V1.3 12/21
Need help?
Do you have a question about the DV26 and is the answer not in the manual?
Questions and answers