Download Print this page

Essex Electronics KE-1000 Mark 3 Quick Start Manual

Advertisement

Quick Links

KE-1000 Mark 3 Programming
Programming the Floor Manager's Code
The Floor Manager's Code does not actuate a relay
A different Floor Manager's Code must be used for each controlled floor.
To Program/Change the Floor Manager's Code for one floor:
1. Select a 3 to 8 digit code that will be used for the Floor Manager's Code.
___ ___ ___ ___ ___ ___ ___ ___
2. Locate the Control Module, remove the cover and locate the black "PROGRAM" button switch on
the daughter board corresponding to the relay for the controlled floor.
3. Press the PROGRAM switch once *. (The Keypad will beep rapidly 4 times)
4. At the Keypad, enter 1-1-1-9 to open the memory (you will hear three rapid beeps) and
immediately enter your new Floor Manager's code.
(Do not let more than five seconds elapse between entries or the system will reset!!!)
5. After entering your new code, wait five seconds for the 3 reset beeps.
6. If there are more than a single controlled floor, repeat this process on each daughter board.
* Once the PROGRAM switch has been pressed, you have 2 minutes to begin programming.
Overview of User Codes
In the KE-1000 Mark 3 applications it is important to keep in mind these things:
- There may be as many as 36 codes installed at one time; clear records are imperative.
- No two codes may be the same; the system will reject an attempt to program a duplicate.
- The Floor Manager's Code does not actuate a relay.
There are a total of 5 User codes (also called Secondary Codes) that can be programmed for each
controlled floor using the KE-1000-Mark 3. User Codes can vary in length from 3 to 8 digits. Each User
Code is programmed into one of 5 User Locations. These Locations are as follows:
User #
User Code 1
User Code 2
User Code 3
User Code 4
User Code 5
Once a User Code has been programmed into a User Location, the User Code can be easily changed or
deleted from the system (see Programming User Codes).
Programming User Codes
To Program a New User Code or Change an Existing User Code:
1. Choose a new 3 to 8 digit code that will be used for this User Code.
___ ___ ___ ___ ___ ___ ___ ___
2. Decide which User Location to place this User Code (see Overview of User Codes)
3. Enter the Floor Manager's Code for the desired controlled floor, followed by the User Location
(you will hear three rapid beeps) and immediately enter the new User Code. (Do not let more than
five seconds elapse between entries or the system will reset!!!)
Example: 1-3-5-7-9 1-1-1 1-2-3-4
4. After entering your new code, wait five seconds for the 3 reset beeps.
User Location
1-1-1
1-1-3
1-1-5
1-1-7
1-1-9

Advertisement

loading

Summary of Contents for Essex Electronics KE-1000 Mark 3

  • Page 1 * Once the PROGRAM switch has been pressed, you have 2 minutes to begin programming. Overview of User Codes In the KE-1000 Mark 3 applications it is important to keep in mind these things: - There may be as many as 36 codes installed at one time; clear records are imperative.
  • Page 2 KE-1000 Mark 3 Programming (continued) To Delete a User Code 1. Enter the Floor Manager's Code, followed by the User Location of the User Code you want to delete (you will hear three rapid beeps). Example: 1-3-5-7-9 1-1-1 2. Wait five seconds for the 3 reset beeps (Do not enter any digits until you hear 3 reset beeps)