Download Print this page
Phoenix Contact VALUELINE IPC Datasheet
Phoenix Contact VALUELINE IPC Datasheet

Phoenix Contact VALUELINE IPC Datasheet

Industrial computer platform

Advertisement

Quick Links

VALUELINE IPC
A configurable industrial computer platform
Data sheet
2643_en_K
1
Description
The Valueline industrial PC (VL IPC) product line is a config-
urable industrial computer platform. A VL IPC system can be
custom configured from various display, CPU, memory and
mass storage options, allowing greater flexibility in matching
hardware to specific application requirements. The robust,
modular design of the VL IPC product streamlines the man-
ufacturing process resulting in faster product delivery times.
The Valueline industrial PC can be integrated with other
Phoenix Contact control and networking products to create
a complete Phoenix Contact automation solution.
The targeted applications for the Valueline industrial PC are:
Machine and process control
Monitoring and visualization
Data acquisition
Database retrieval and storage
NOTE:
Circuit ground (0 V) and functional earth ground (FE) are connected.
Make sure you always use the latest documentation.
It can be downloaded at phoenixcontact.com.
This data sheet is valid for all products listed on the following page:
© PHOENIX CONTACT 2014-09-19
2
Features
Compact, rugged housing
Flexible mounting options
Wide variety of touch screen display sizes with or
without USB port
Removable hard-disk drive, solid-state drive and
CompactFlash
Two integrated 10/100/1000 Ethernet ports with
independent MAC addresses
Up to 3 GB RAM
Up to two CompactFlash slots
Two optional slots allow installation of PCI cards for
direct connection to fieldbus networks or other
applications
®
data storage options

Advertisement

loading
Need help?

Need help?

Do you have a question about the VALUELINE IPC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Phoenix Contact VALUELINE IPC

  • Page 1 – Two integrated 10/100/1000 Ethernet ports with The Valueline industrial PC can be integrated with other independent MAC addresses Phoenix Contact control and networking products to create – Up to 3 GB RAM a complete Phoenix Contact automation solution. –...
  • Page 2: Ordering Data

    VALUELINE IPC 2913108 An order key must be appended to the 7-digit order number to reflect the various options that are specified in each configuration. The order key is generated using the Phoenix Contact on-line configuration tool. Accessories Description Type Order No.
  • Page 3 VALUELINE IPC Temperature data (operating) No display 17-in. display 18.5-in.display 12-in. display 19-in. display 21.5-in.display 15-in. display 24-in. display ® ® Celeron M and Core™2 Duo with CompactFlash card or solid-state drive -20 …40°C -20 … 45°C 0 … 45°C Celeron M and Core 2 Duo with rotating hard-disk drive 0 …...
  • Page 4 VALUELINE IPC Display - 24 in. Screen size, diagonal 608 mm (24.0 in.) Screen size, horizontal x vertical 531 x 299 mm Resolution 1920 x 1080 Type Resistive touch screen Brightness 300 Cd/m² Number of colors 16.7 million Contrast ratio 1000:1 View angle, horizontal/vertical (CR=10), typ.
  • Page 5 VALUELINE IPC Display - 18.5 in. Screen size, diagonal 470 mm (18.5 in.) Screen size, horizontal x vertical 410 x 230 mm Resolution 1366 x 768 Type Resistive touch screen Brightness 300 Cd/m² Number of colors 16.7 million Contrast ratio 1000:1 View angle, horizontal/vertical (CR=10), typ.
  • Page 6 VALUELINE IPC Display - 12 in. Screen size, diagonal 307 mm (12.1 in.) Screen size, horizontal x vertical 246 x 185 mm Resolution 800 x 600 Type Resistive touch screen Brightness 400 Cd/m² Number of colors 16.2 million Contrast ratio 600:1 View angle, horizontal/vertical (CR=10), typ.
  • Page 7: Installation

    VALUELINE IPC Installation Wall-mount and bookshelf installation Wall mounts are valid for VL IPCs that do not include a display. Use this type of mounting to install the VL IPC on the inside of a cabinet. The VL IPC can be attached to a flat surface in either a wall mount or bookshelf orientation. Either way, attach the unit using the four keyholes.
  • Page 8 VALUELINE IPC From the front, push the VL IPC through the opening. Ensure the gasket is properly positioned in the groove. From the rear, place the display clamps, 1, in the slots, 2, on the display and slide the clamp to the right (see Figure 4).
  • Page 9 VALUELINE IPC External display External displays can be connected to the VL IPC to function ② as a desktop extension or as an auxiliary display. Use the ① VGA port for analog displays and DVI-D port for digital dis- plays.
  • Page 10 VALUELINE IPC ② ⑥ PCI Slot 1 ④ ① ③ ① ⑤ Figure 6 Side panel and bracket removal c) Line up the card’s connectors with the PCI slot connector, 6. Carefully push the card into the ③ connector. After it is fully inserted in the connector, the card bracket should be aligned with the bracket frame.
  • Page 11 Microsoft Software Li- cense. Phoenix Contact is not responsible and cannot be held liable for proper use of the operating system or any other software installed on the computer unless that soft- ware is a product developed and manufactured by Phoenix Contact.
  • Page 12: Maintenance

    VALUELINE IPC Using CompactFlash cards Install a CompactFlash card in the proper slot (see “VL IPC components” on page 12). The card should be ® VL IPC CompactFlash slots are not hot-swappable. The inserted so the lip is toward the connectors. Push the eject button is only to be used once the VL IPC is powered card straight into the device until seated.
  • Page 13 VALUELINE IPC ⑯ ⑮ ⑭ ⑬ ⑫ ERROR X7 USB X5 USB X1: PWR 24VDC X6 USB X4 USB X3 ETH X2 ETH – X10 COM1 X9 VGA X8 DVI D ① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩...
  • Page 14 VALUELINE IPC ⑩ ⑫ ⑪ ERROR X7 USB X5 USB X1: PWR 24VDC X3 ETH X2 ETH X6 USB X4 USB – X9 COM X8 VGA ① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ Serial port Removable hard disk drive...
  • Page 15 BIOS configuration settings without specific instruction from b) Follow the Item Help directions on the right side to Phoenix Contact Technical Services, this is something that move (prioritize) a highlighted device up or down in may be necessary. To access the BIOS configuration, there the list.
  • Page 16 Former-Sts - for the VL IPC to maintain its on or off status before power is restored. Press the <Enter> key to accept the change. Save the change and confirm it. PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany 2643_en_K www.phoenixcontact.com...

This manual is also suitable for:

2913108