Advertisement

Quick Links

EN
IC3-CONTROL
INSTALLATION
AND OPERATION MANUAL
ver.1 11-12-2019

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IC3-CONTROL and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for 2VV IC3-CONTROL

  • Page 1 IC3-CONTROL INSTALLATION AND OPERATION MANUAL ver.1 11-12-2019...
  • Page 2: Before Starting

    The assessment was conducted pursuant to harmonized European standards included in the relevant EC Declaration of Conformity. The current and full version of the EC Declaration of Conformity can be found at www.2vv.cz 2VV. Creating innovative solutions for you and your business since 1995.
  • Page 3 If the product was shipped at below 0°C temperatures, let it • rest for at least 2 hours, without turning it on, so that its inner temperature can match the surroundings. Regulator IC3-S-EC 2VV. Creating innovative solutions for you and your business since 1995.
  • Page 4: Main Parts

    Grounding bridge (PE) Null bridge (N) Connector terminal Regulator lid block Source Control electronics AC module Cable glands Regulator IC3-*-EC Source Regulator lid Connector terminal block Cable glands Control electronics 2VV. Creating innovative solutions for you and your business since 1995.
  • Page 5 DATUM: 16.3.2016 NÁZEV 2VV s.r.o., Poděbradská 289 OE-M-AC5 CZ-530 09 PARDUBICE SCHVÁLIL: Josef Řezníček A DATUM: 14.3.2016 ČÍSLO VERZE MĚŘÍTKO PROMÍTÁNÍ 2-602-S06285 2VV s.r.o., Poděbradská 289 CZ-530 09 PARDUBICE 2VV. Creating innovative solutions for you and your business since 1995.
  • Page 6: Technical Parameters

    The regulator is fixed to the wall with screws and wall plugs or with bolts. There must be no flammable materials at a distance shorter than 100 mm from the regulator. min. 500 mm 2VV. Creating innovative solutions for you and your business since 1995.
  • Page 7 The adequacy of the circuit breakers will depend on the conditions specific to the place of installation. The following table is for reference only. AC-S AC-C IC3-S-AC5-04 IC3-C-EC IC3-C-AC5-04 IC3-C-AC5-07 IC3-S-AC5-07 IC3-S-EC IC3-C-AC5-16 IC3-S-AC5-16 Connection of the control * Recommended UTP CAT5 data cable (twisted pair) 2VV. Creating innovative solutions for you and your business since 1995.
  • Page 8 6. INSTALLATION IC3-C-AC Heat L-Fan Heat-1 Heat-2 0-10V L-in L-out L-in L-out 6364 65 66 SLAVE UNIT MODBUS 2VV. Creating innovative solutions for you and your business since 1995.
  • Page 9 L-Fan Heat-1 Heat-2 0-10V Slave unit 24 23 22 Recommended Alarm Heater wiring overheat Thermostat overheat Thermostat Safety Thermostat Door Room External contact thermostat control 17 18 MASTER UNIT 2VV. Creating innovative solutions for you and your business since 1995.
  • Page 10 TACHO/RPM - MOTOR 4 TACHO/RPM - MOTOR 5 TACHO/RPM - MOTOR 6 TACHO/RPM - MOTOR 7 SLAVE UNIT TACHO/RPM - MOTOR 8 MODBUS TACHO/RPM - MOTOR 9 TACHO/RPM - MOTOR 10 2VV. Creating innovative solutions for you and your business since 1995.
  • Page 11 TACHO/RPM - MOTOR 4 TACHO/RPM - MOTOR 5 overheat TACHO/RPM - MOTOR 6 Thermostat TACHO/RPM - MOTOR 7 TACHO/RPM - MOTOR 8 TACHO/RPM - MOTOR 9 TACHO/RPM - MOTOR 10 Safety Thermostat 2VV. Creating innovative solutions for you and your business since 1995.
  • Page 12 The total bus length of all chained air curtains must not exceed 150m !!! SLAVE SLA- SLA- no.1 no. 6 no.2 no. 7 no. 3 no. 8 no. 4 no. 9 no. 5 no. 10 2VV. Creating innovative solutions for you and your business since 1995.
  • Page 13: Description Of Main Screen

    Shows current temperature, air flow, hea- ting level, time and control mode. The menus are described below Information page 15 icons page 16 page 18 Device cooling Night redu- Time mode ction DOOR mode 2VV. Creating innovative solutions for you and your business since 1995.
  • Page 14: Current Status

    Display the current air flow Current date and time status Reduce or increase opening’s air flow (with closed doors) Confirm Confirm Back to main screen + return + return 2VV. Creating innovative solutions for you and your business since 1995.
  • Page 15 Copy + return Annual mode START / STOP interval Tap to add a new time mode CANCEL Only MANUAL Required ventilation rate in manual mode Required heating rate in manual mode 2VV. Creating innovative solutions for you and your business since 1995.
  • Page 16 IC3 gate 1 ler press “Save” for saving the unit to the app. After scanning QR code from the controller press “Save” for saving the unit to the app. 2VV. Creating innovative solutions for you and your business since 1995.
  • Page 17: Servicing Menu

    And join the 1+2 connectors per the schematic below. If you set the function AUTO or MANUAL, certain items can be enabled/disabled in the servicing MENU 2VV. Creating innovative solutions for you and your business since 1995.
  • Page 18 Inlet - Temperature sensor for part of device tray (before heat exchanger) Room - Spatial temperature sensor (for example, in the room) Thermostat - Spatial thermostat (functions ON/OFF) Room BMS - Spatial temperature sensor from master system 2VV. Creating innovative solutions for you and your business since 1995.
  • Page 19 Required temperature with open doors Overrun mode: at a set time, or upon achieving a specific temperature 2VV. Creating innovative solutions for you and your business since 1995.
  • Page 20 Not allowed = The SLAVE regulators are turned on/off simultaneously Allowed = The SLAVE regulators can be turned on/off individually Need to set to activate form the main screen Selflearnig. 2VV. Creating innovative solutions for you and your business since 1995.
  • Page 21 Display mode of Menu Adv. fan setting for AC5 Electrical connection - Option 1: and EC IC3-AC5 IC3-EC +12V CANL CANH +12V 2VV. Creating innovative solutions for you and your business since 1995.
  • Page 22: Menu - Factory Reset

    Use this to reset the default values Press “FACTORY RESET” to reset the default values of MENU 1616 Once completed, we recommend to turn the main supply off and on. 2VV. Creating innovative solutions for you and your business since 1995.
  • Page 23 The heater overheats due to insufficient air flow. Check off automatically operational that the ventilators are in good order and that the air but not supply is not disrupted. heating 2VV. Creating innovative solutions for you and your business since 1995.
  • Page 24: Maintenance

    10.1 IF YOU ARE UNABLE TO REPAIR THE UNIT If you were unable to solve a problem, contact the supplier or the representative of 2VV. Warranty and post-warranty service are provided by the supplier or an authorised service included in the list available at the supplier’s.
  • Page 25: Wiring Diagram

    Transformer (4A / 7A / 16A) Power supply PCB modul A PCB modul AC Relé SSR (only 16A type) IC3-*-EC-* Označení Popis Power PCB modul A PCB modul TACHO 2VV. Creating innovative solutions for you and your business since 1995.
  • Page 26 25 26 27 28 29 30 63 64 65 66 CONTROL PANEL SLAVE +12V SLOT CANH CANL IC3-C-AC5-16 Název: IC2-C-AC5-16 Firma: 2VV Číslo: 2-602-S08999 Kreslil: Mojžíš Verze: 3 Datum: 6.11.2018 2VV. Creating innovative solutions for you and your business since 1995.
  • Page 27 NTC 10K RELAY HEAT 1 HEAT L I-BUS AC3-M RELAY HEAT 2 63 64 IC-SUPERIOR IC3-S-AC5-16 (MASTER) Název: IC2-S-AC5-16-EV Firma: 2VV Číslo: 2-602-S09217 Kreslil: Mojžíš Verze: 3 Datum: 07.112018 2VV. Creating innovative solutions for you and your business since 1995.
  • Page 28 MASTER UNIT USED +12V 4 5 6 7 8 9 10 11 12 13 14 15 Název: IC2-EC-S-EV Firma: 2VV Číslo: 2-602-S09218 Kreslil: Mojžíš IC3-EC-S Verze: 3 Datum: 7.11.2018 2VV. Creating innovative solutions for you and your business since 1995.
  • Page 29 In case of any doubt or query, do not hesitate to contact our sales or technical support departments. CONTACT Address: 2VV, s.r.o., Fáblovka 568, 533 52 Pardubice, Czech Republic Internet: http://www.2vv.cz/ 2VV. Creating innovative solutions for you and your business since 1995.

Table of Contents