The assessment was conducted pursuant to harmonized European standards included in the relevant EC Declaration of Conformity. The current and full version of the EC Declaration of Conformity can be found at www.2vv.cz 2VV. Creating innovative solutions for you and your business since 1995.
Page 3
If the unit was shipped at temperatures below 0°C, let it • rest for at least 2 hours without turning it on, so that its interior temperature can match the surroundings. 2VV. Creating innovative solutions for you and your business since 1995.
3. MAIN SECTION SC-x-ACx SC-x-EC Regulator lid Cable housing Connecting distributor plate Source AC module Grounding bridge (PE) Null bridge (N) Controlling electronics 2VV. Creating innovative solutions for you and your business since 1995.
Page 5
DATUM: 16.3.2016 NÁZEV 2VV s.r.o., Poděbradská 289 OE-M-AC5 CZ-530 09 PARDUBICE SCHVÁLIL: Josef Řezníček A DATUM: 14.3.2016 ČÍSLO VERZE MĚŘÍTKO PROMÍTÁNÍ 2-602-S06285 2VV s.r.o., Poděbradská 289 CZ-530 09 PARDUBICE 2VV. Creating innovative solutions for you and your business since 1995.
The regulator must be installed in such a way as to ensure sufficient access in the event of maintenance, servicing, or disassembly. The regulator is fixed to the wall using screws and anchors or bolts. No flammable materials may be kept within 100 mm of the regulator. min. 500 mm 2VV. Creating innovative solutions for you and your business since 1995.
Page 7
Table of minimum sizes of breakers according to the regulator model. The suitability of the breaker always depends on the specific conditions at the site of installation. The following table is for orientation purposes only!!! AC-S AC-C SC-S-AC5-04 SC-C-EC SC-C-AC5-04 SC-S-AC5-07 SC-S-EC SC-C-AC5-07 SC-S-AC5-16 SC-C-AC5-16...
Page 8
6. INSTALLATION 6. INSTALLATION SC-C-AC Heat Heat-1 Heat-2 L-Fan 0-10V L-in L-out L-in L-out 6364 65 66 SLAVE MODBUS 2VV. Creating innovative solutions for you and your business since 1995.
Page 9
6. INSTALLATION 6. INSTALLATION SC-S-AC Heat Heat-1 Heat-2 L-Fan 0-10V Slave unit 24 23 22 External control MASTER 2VV. Creating innovative solutions for you and your business since 1995.
Page 10
TACHO/RPM - MOTOR 4 TACHO/RPM - MOTOR 5 TACHO/RPM - MOTOR 6 TACHO/RPM - MOTOR 7 SLAVE TACHO/RPM - MOTOR 8 TACHO/RPM - MOTOR 9 TACHO/RPM - MOTOR 10 MODBUS 2VV. Creating innovative solutions for you and your business since 1995.
Page 11
TACHO/RPM - MOTOR 8 TACHO/RPM - MOTOR 9 necessary to take into consideration any possible decrease in power!!! TACHO/RPM - MOTOR 10 The minimum power for the lowest engine performance is 1.5V!!! 2VV. Creating innovative solutions for you and your business since 1995.
Page 12
SLAVE MASTER no.1 no.2 no.10 Max 150m The total length of the bus of all chained shutters may not exceed a length of 150m!!! SLAVE SLAVE SLAVE . 10 2VV. Creating innovative solutions for you and your business since 1995.
(day/night) mode. Informational The individual MENUs are described later in this manual icon page 13 page 14 Cooling the device page 17 Night mode Time mode DOOR mode 2VV. Creating innovative solutions for you and your business since 1995.
Blower power with closed doors may be limited in the menu 1616 Adv. fan setting. After exceeding the limit, the blower power is restricted according to the limit. Confirm Return to main screen + return 2VV. Creating innovative solutions for you and your business since 1995.
CANCEL When activating this field the regulator turns off at the set time on the timer. This setting is not observed in the timer mode. Desired heating power. 2VV. Creating innovative solutions for you and your business since 1995.
And join the 1+2 connectors per the schematic below. Activation/deactivation of automatic motor rotation control by temperature If no engine with tacho or termo contact is connected. Connectors 1 and 2 must be connected. 2VV. Creating innovative solutions for you and your business since 1995.
Page 17
Room BMS - Spatial temperature sensor from master system Enabling/disabling DHCP Manual entry of regulator network settings: IP address Mask Gate Incorrect settings can lead to inability to communicate with the regulator 2VV. Creating innovative solutions for you and your business since 1995.
Page 18
If the outdoor temperature sensor is not set, the “summer heating” mode operates only according to the se- lected time and the set temperature is not assessed 2VV. Creating innovative solutions for you and your business since 1995.
Page 19
After reaching the desired temperature in the space, the fan and the heating are deactivated. During temperature drops by the set hyster- esis, the fan and heating once again reactivate. 2VV. Creating innovative solutions for you and your business since 1995.
Page 20
MENU 1616 +12 V to the outgoing CANL CANH +12 V After completion it is recommended that you deactivate and connect the main power supply of the regulator 2VV. Creating innovative solutions for you and your business since 1995.
Check proper connection of sensor to electron- perature sensor not working sor on connectors 55.56 ics, if applicable test sensor functionality using failure (55,56) resistance measurement (resistance value at +20°C is approx. 10kW) 2VV. Creating innovative solutions for you and your business since 1995.
Page 22
Respect the connection schematic and limit phenomena that could disrupt communications (cables in the vicinity of high voltage, phenomena at the site of installation that could cause disruption) 2VV. Creating innovative solutions for you and your business since 1995.
Transformer (4A / 7A / 16A) Power supply PCB module A/B PCB module AC Auxiliary SSR (only with version 16A) SC-C/S-EC Designa- Description tion Power supply PCB module A/B PCB module TACHO 2VV. Creating innovative solutions for you and your business since 1995.
Page 24
13 14 15 16 17 18 19 20 21 22 23 24 I-BUS OUTPUT AC5-v1 REL 6 REL 5 REL 4 REL 3 REL 2 REL 1 zdroj zdroj 2VV. Creating innovative solutions for you and your business since 1995.
Page 25
28 27 26 25 24 23 22 21 +12V ALARM OUTLET I-BUS ROOM HEAT INLET AC5-v1 REL 6 REL 5 REL 4 REL 3 REL 2 REL 1 zdroj zdroj 2VV. Creating innovative solutions for you and your business since 1995.
Page 26
13 14 15 16 17 18 19 20 21 22 23 24 I-BUS OUTPUT AC5-v1 REL 6 REL 5 REL 4 REL 3 REL 2 REL 1 zdroj zdroj 2VV. Creating innovative solutions for you and your business since 1995.
Page 27
28 27 26 25 24 23 22 21 20 19 18 17 16 +12V ALARM OUTLET I-BUS ROOM HEAT INLET AC5-v1 REL 6 REL 5 REL 4 REL 3 REL 2 REL 1 zdroj zdroj 2VV. Creating innovative solutions for you and your business since 1995.
Page 28
11. WARING DIAGRAM 1 2 3 4 5 6 7 8 9 RELAY RELAY RELAY RELAY RELAY FUSE 57 58 59 60 61 62 2VV. Creating innovative solutions for you and your business since 1995.
Page 29
11. WARING DIAGRAM 1 2 3 4 5 6 7 8 9 RELAY RELAY AC5-M AC5-M ANALOG HEAT EC FAN 0-10 29 30 31 32 33 34 2VV. Creating innovative solutions for you and your business since 1995.
Page 30
The manufacturer shall not be held liable for any damages caused to the device due to unqualified installation and opera- tion in conflict with this guide and common practice for installation and operation of HVAC units and regulation systems 2VV. Creating innovative solutions for you and your business since 1995.