Superior Fireplaces DRL2000 Series Installation And Operation Instruction Manual

Superior Fireplaces DRL2000 Series Installation And Operation Instruction Manual

Table of Contents

Advertisement

P/N 900994-00 REV. K 07/2021
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 900994-02
P900994-00
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future
reference.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only)
or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit
f i r e - p a r t s . c o m
is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d'autres gaz, sauf si une trousse de conversion est utilsée.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instruc-
tions.
• If you cannot reach your gas supplier, call the
fire department.
- Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
Installation and Operation Instructions
DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces
Models
C
US
Report No. F19-008
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour
consultation ultérieure.
DRL2035TEN
DRL2045TEN
DRL2055TEN
AVERTISSEMENT:
RISQUED'INDENDIE OU D'EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d'entraîner des blessures graves, la mort
ou des dommages matériels.
- Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où
vous trouvez.
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L'installation et l'entretien doivent être assurés par
un installateur ou un service d'entretien qualifié
ou par le fournisseur de gaz.
DRL3535TEN
DRL3545TEN
DRL3555TEN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DRL2000 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Superior Fireplaces DRL2000 Series

  • Page 1 Installation and Operation Instructions DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces Models P/N 900994-00 REV. K 07/2021 DRL2035TEN DRL3535TEN Ce manuel est disponible en francais, simplement en faire la demande. Numéro de la pièce 900994-02 DRL2045TEN DRL3545TEN Report No. F19-008 DRL2055TEN DRL3555TEN P900994-00...
  • Page 2: General Information

    Innovative Hearth Products General Information DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 SAFETY AND YOUR FIREPLACE See attached color flyer for proper color representation DANGER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS.
  • Page 3 Innovative Hearth Products General Information DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 La sécurité et Safety and Your Seguridad y su votre foyer Fireplace chimenea All parts of your ¡Todas las partes de la Toutes les parties de votre IHP fireplace get chimenea IHP se ponen foyer IHP deviennent...
  • Page 4: Table Of Contents

    Innovative Hearth Products General Information DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 DRL2035, DRL3535, DRL3545 & DRL3555 DRL2045 & DRL2055 We recommend that our gas hearth products be installed and serviced by professionals who are certi ed in the U.S. by the National Fireplace Institute®...
  • Page 5: Important Safety Information

    Innovative Hearth Products General Information DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 IMPORTANT SAFETY INFORMATION Important Safety Informa- L’information de sûreté Información importante de tion importante seguridad 1. WARNING: Do not operate appliance 1. AVERTISSEMENT. Ne pas utiliser l’appareil 1.
  • Page 6: Fireplace Installation, Operation, And Maintenance Notices

    Innovative Hearth Products General Information DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 APPLIANCE INSTALLATION, SERVICE, AND MAINTENANCE NOTICES WARNING Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
  • Page 7 Innovative Hearth Products General Information DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 APPLIANCE OPERATION NOTICES These fireplaces are vented gas appliances. Do not burn wood or other material in these appliances. These appliances are designed to operate on natural gas or propane gas only. The use of other fuels or combinations of fuels will degrade the performance of this system and may be dangerous.
  • Page 8: Packaging List

    DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 INSTALLATION PACKAGING All DRL2000 series models include The assembled vented gas fireplace heater is packaged with: • Literature Kit (bag in bottom compartment containing Installation and Operation Instructions (this manual), Hot Glass Safety Flyer, and Safety-In-Operation Warning Labels) •...
  • Page 9: Gas Pressure

    Innovative Hearth Products General Information DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 BTU Input Table 1 - Input Rate (BTU/HR), Gas Valves Propane/LP Gas Natural Gas (Field Converted) Burner Model High Rate Low Rate High Rate Low Rate NOTE: *Propane/ LP models are available through DRL2035 15,000...
  • Page 10 Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 NOTE: Before accessing the test ports, the fireplace must be OFF and COLD. Turn OFF the main gas supply before connecting to the pressure taps. Propane tanks are at pressures that will cause damage to valve components. Verify that the tanks have step down regulators to reduce the pressure to safe levels.
  • Page 11: Requirements For The Commonwealth Of Massachusetts

    Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS These appliances are approved for installation in the US state of Massachusetts if the following additional requirements are met: • Install this appliance in accordance with Massachusetts Rules and Regulations 248 C.M.R. Sections 4.00 through 8.00.
  • Page 12: Manufactured Home Requirements

    Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 MANUFACTURED HOME REQUIREMENTS This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. Cet appareil peut être installé dans une maison préfabriquée (mobile) déjà installée à demeure si les règlements locaux le permettent.
  • Page 13: Vent Termination Clearances

    Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 VENT TERMINATION CLEARANCES These instructions should be used as a guideline and do not supersede local codes in any way. Install venting with the most restrictive requirements as outlined in these instructions, local codes, these instructions, the current National Fuel Gas Code (ANSI Z223.1/NFPA 54) in the USA or the current standards of CAN/CGA-B149.1 in Canada.
  • Page 14 Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 Table 7 - Horizontal vent termination clearances for buildings with combustible and noncombustible exteriors Inside Corner Outside Corner Recessed Location See Table 6 Fixed Balcony with No Side Wall Balcony with Perpendicular Side Wall Openable Fixed Closed...
  • Page 15: Minimum Clearances To Combustibles

    Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 MINIMUM CLEARANCES TO COMBUSTIBLES Table 8 - Minimum Clearances * 1/2” (13 mm) to wrapper Fireplace And Vent Clearances Back *** 0” (0 mm) to Spacers The fireplace is approved with zero clearance to combustible materials 1/2”...
  • Page 16: Wall Finishes / Surrounds / Mantels

    Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 Mantel Clearances Figure 5 - DRL2000 Series, Standard Installation Figure 5A - DRL3500 Series, Standard Installation Mantel depth Mantel depth 14 (356) 16 (407) 12 (305) 14 (356)
  • Page 17: Installation Preparation

    Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 INSTALLATION PREPARATION The fireplace is shipped with all gas controls and components installed and pre-wired. Before installing the fireplace, follow these steps: 1. Remove the shipping carton, and retain the front of the carton (used to protect the fireplace during construction). 2.
  • Page 18 Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 Table 10 - Standard Framing Specifications Framing construction to be 2 x 4 or larger 10-1/2 (267) Front to rear with 1” distance to wall 7 (178) 12-1/8 (308) 0”...
  • Page 19 Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 FRAMING AND FINISHING Continued Table 12 - Fireplace Framing Dimensions For HeatFlo Installations - Flush Wall & Recessed Wall Pocket f i r e - p a r t s . c o m with HeatFlo Kit with HeatFlo Kit for Recessed Wall Pocket...
  • Page 20 Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 Ceiling HeatFlo Vent Opening (A) TV Above fire- Television (TV) 12” (305 mm) place Opening (B) TV Below Vent 3” (77 mm) Opening (C) Vent Opening 4” (102 mm) Min.
  • Page 21: Prepare The Fireplace Top Spacers

    Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 Prepare the Fireplace Top Spacers 1. The two (2) 4” standoff spacers on top of the fireplace cabinet are shipped flat. Remove the screw adjacent to the detached end (Figure 7).
  • Page 22: Installing Header Shield Compass Dlx Models

    Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 Installing Header shield (DRL3500 series models only) Figure 11 - Installing Header Shield Standoffs Screw Header Shield f i r e - p a r t s . c o m Step 1: Remove screw holding standoff to firebox, bend to 4”...
  • Page 23: Place The Fireplace In The Framing And Secure

    Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 Place the Fireplace in the Framing and Secure NOTE: Nailing flanges, combustible members, and screw heads in areas directly adjacent to the nailing flanges are EXEMPT from the 1/2” clearance to combustible requirements for the firebox outer wrapper. NOTE: Combustible framing may be in direct contact with the nailing flanges and may be located within 1/2”...
  • Page 24 Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 Figure 12 - When to use a vent restrictor Figure 13 - Vent restrictor installation, Top vent 2 1/2” None Break-Away 3” Base 3” Base + wing U-Shaped Vent 60 ft Maximum vertical run Restrictor...
  • Page 25: Connecting The Vent Pipe

    Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 Vent Restrictor with Horizontal Terminations When horizontally terminating a vent system with a vertical vent run up to 4 ft through an exterior wall, no vent restrictor is required. If installing more than 6 ft of vertical venting, install the restrictor (Figure 13, Page 24), from inside or outside the unit, in the inner fireplace collar.
  • Page 26 Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 Elbow Heat Shield (35” & 45” 3500 series Models Only) If using a 90 degree elbow directly off fireplace, the elbow shield is required. Install per instructions in Figure 18. NOTE: Same installation applies if installed in a corner.
  • Page 27 Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 Vent section length table Table 15 will assist calculating how many vent sections are needed for the planned vent configuration. When a vent section is engaged with another section, its effective length will be 1-1/2” shorter. Table 15 - Vent Section Length Nominal Section Nominal Section Length...
  • Page 28: Install The Vent System

    Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 Clearance to combustibles Maintain the minimum clearance to combustibles (e.g., framing, • 1” (26 mm) from all sides attic, ceiling insulation, etc.). For all vertical runs: NOTE: Attic insulation shield (H3907, see Page 29) must be •...
  • Page 29 Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 Vertical (Offset) Installation 1. Analyze the vent route and determine the number of vent sections and elbows required—See Effective Vent Length on Pages 25-27 for more information. Plan the venting so that a joint does not occur in the ceiling or roof joists.
  • Page 30 Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 7. Change vent direction of horizontal/inclined run—Install the SV4.5E45 and SV4.5E90 elbows in the same manner as the straight vent sections. See Vent elbows on Page 25 for more information. 8.
  • Page 31 Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 Vertical Vent Figures/Tables NOTE: Secure Vent rigid vent pipe is shown in the figures; Secure Flex flexible vent pipe may also be used. ® ® NOTE: Rise per foot run ratios are acceptable all the way to level. For best results, maintain the horizontal/inclined run in a straight (no dips), slightly elevated plane of approximately 1/4”...
  • Page 32 Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 Table 17 - Top Vent—Two 90° Elbows Table 18 - Top Vent—Three Elbows Ceiling firestop/ spacer SV4.5VF Wall firestop/ spacer SV4.5HF ** Ceiling firestop/ spacer SV4.5VF * Wall firestop/ spacer SV4.5HF ** When using Secure Flex...
  • Page 33 Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 Install the Horizontal Termination Vent System These instructions should be used as a guideline and do not supersede local codes in any way. Install venting with the most restrictive requirements as outlined in these instructions, local codes, these instructions, the current National Fuel Gas Code (ANSI-Z223.1) in the USA or the current standards of CAN/CGA-B149.1 in Canada.
  • Page 34 Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 8. Change vent direction—At transition from or to a horizontal/inclined run, install SV4.5E45 or SV4.5E90 elbows in the same manner as the straight vent sections. The elbows feature a twist section to allow them to be routed about the center axis of their initial collar section to align with the required direction of the next vent run element.
  • Page 35 Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 Figure 27 - Installing the Horizontal Termination Installing the Horizontal Termination, SV4.5HT-2 To help minimize water infiltration Firestop/Spacer (SV4.5HF) shown Typical or SV4.5HTSS it is recommended that the Fire- Termination on the exterior side of the wall.
  • Page 36 Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 Table 19 - Venting Components Required for Various Exterior Wall Thicknesses, when using Typical Termination Kits Vent Components Required Exterior Wall Thickness Termination Kit Only 6 to 9-1/4” (152 to 235 mm) Termination Kit and 6”...
  • Page 37 Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 Table 21 - Top Vent—One 90° Elbow, Elbow Connection NOT at Fireplace H Maximum V Minimum feet meters feet meters 1.524 0.305 3.048 0.610 4.572 0.914 When using Secure Flex, use Firestop/Spacer 7.62 1.524...
  • Page 38 Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 Table 23 - Top Vent—Three 90° Elbows H Maximum V Minimum feet meters feet meters When using Secure Flex , use ® *When using Secure Flex, use ceiling firestop/spacer SF4.5VF.
  • Page 39 Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 Vertical or Horizontal Venting Using Secure Flex Kits and Components ® When Secure Flex kits are used in a rear flue, horizontal termination installation, at least 1 ft of vertical rise is required. ®...
  • Page 40 Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 2. Install the outer Flex Pipe. a. Install the large gear clamp loosely around the outer flexible vent pipe, then push it back out of the way. b.
  • Page 41: Complete The Field Wiring

    S’assurer que l’appareil fonctionne adéquatement une fois l’entretien terminé. The gas valve is set in place and pre-wired at the factory for the Electronic wiring 2000 series. Electronic Wiring DRL2000 series One of the following optional controls must be used: •...
  • Page 42 Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 Figure 32 - Wiring Diagram—Electronic Gas Valve DRL2000 Series ELECTRONIC WIRING DIAGRAM FOR GRAVITY VENT FIREPLACES JUNCTION BOX AC/DC 120V AC POWER ELECTRONIC PILOT ASSEMBLY ADAPTOR IGNITER ROD...
  • Page 43 Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 Figure 33 - Wiring Diagram—Electronic Gas Valve DRL3500 Series IPI Pilot Flame Sensor Schematic Representation Only Spark Electrode COLOR CODE: B = BLACK Pilot Tube BB = BROWN W/BLACK STRIPE BG = BROWN W/GREEN STRIPE BL = BLUE BR = BROWN...
  • Page 44: Connect The Gas Line

    Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 Connect the Gas Line All codes require a shutoff valve mounted in the supply line. Figure 35 illustrates two methods for connecting the gas supply. The flex-line method is acceptable in the U.S., however, Canadian requirements vary depending on locality. Installation must be in compliance with local codes.
  • Page 45: Verify Proper Fireplace Operation

    Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 Verify Proper Fireplace Operation 1. With the gas line installed, inspect the system before closing the front of the unit. 2. Follow the pilot lighting instructions: • 2000 series electronic systems Pages 67-68 •...
  • Page 46: Initializing The Remote Control System

    Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 15. Initializing the Remote Control System (3500 models) After completing fireplace installation, initialize the remote control system before operating the fireplace. Insert the three (3) provided AAA batteries into the battery bay in the transmitter, taking care to correctly align polarity ( + / - ).
  • Page 47: Install The Porcelain Liner Panels

    Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 Install the Porcelain Liners (Optional Kit) follow instructions included with optional kit 1. Install the Firebox Liners ( Install the Glass Media 1. See Pages 58 - 59 for instructions on Installing the glass media. Install Interior Options - see Page 65 (follow instructions included with optional accessories) Install the Glass Door 1.
  • Page 48 Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 Figure 38 - Air Shutter Adjustment Rod Table 24 - Air Shutter Adjustment Guidelines Adjustment Amount of Primary Air Flame Color Air Shutter Adjustment Set-Screw If air shutter is Flame will Air shutter gap should be increased closed too far...
  • Page 49: Install The Hood

    Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 Install the Hood after fireplace is cool NOTE: All models must have a hood installed prior to operation. NOTE: Hood is slotted and has some adjustment. It is suggested that the center screw should be installed first and the ends last.
  • Page 50: Re-Installation Of Required Screen Barrier Assembly

    Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 24. Installation/Re-installation of the required screen barrier assembly 1. The screen barrier assembly has four receiving slots that will hook over the four tabs on the fireplace then slide down in place (Figure 42). Figure 42 - Barrier Installation - Barrier Hook View Tab with Barrier Hook...
  • Page 51 Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 26. INSTALLER - ATTACHING SAFETY-IN-OPERATION WARNINGS It is the installers responsibility to ensure these warnings are properly affixed during installation. These warning labels are a critical step in informing consumers of safe operation of this appliance. ATTACHING SAFETY IN OPERATION WARNINGS APPOSITION DES MISES EN GARDE RELATIVES COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD...
  • Page 52: Installation Accessories

    Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 INSTALLATION ACCESSORIES IMPORTANT NOTE: The installation accessories shown in this section are part of the safety agency listing for the product models represented in this manual. Listed Secure Vent Components ®...
  • Page 53 Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 Listed Secure Vent Components ® Cat. No. Model Description Cat. No. Model Description 96K93 SV4.5SU Support Strap 77L76 SV4.5E45 45° Elbow, Corrugated Horizontal Riser Kit, 14”(see 99L02 SV4.5HRK14 750146M) Horizontal Riser Kit, 36”...
  • Page 54: Conversion Kits

    Innovative Hearth Products Installation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 GAS CONVERSION KITS WARNING This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion, or the production of carbon monoxide may result;...
  • Page 55: Operation

    Innovative Hearth Products Operation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 OPERATION WARNING Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house.
  • Page 56 Innovative Hearth Products Operation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 HOMEOWNER’S INSTRUCTIONS - ATTACHING SAFETY IN OPERATION WARNINGS ATTACHING SAFETY IN OPERATION WARNINGS APPOSITION DES MISES EN GARDE RELATIVES COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD À LA SÉCURITÉ D’UTILISATION EN OPERACIÓN Your fireplace has been furnished with safety instruc- tion labels that are to be affixed to the operation and...
  • Page 57: Burn-In Period

    Innovative Hearth Products Operation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 Burn-in Period The first few times this fireplace is operated, there will be an odor from the curing of paint and the burning off of the lubricants used in the manufacturing process. Depending on usage, the burn-in period may take a few hours or a few days.
  • Page 58 Innovative Hearth Products Operation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 Install the Glass Media WARNING • Turn OFF all gas and electricity to the appliance before installing the embers, and logs. • Do NOT install the logs until the appliance has been completely installed, the gas line connected and tested for leaks, and the initial burner operation has been confirmed.
  • Page 59 Innovative Hearth Products Operation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 (Figure 46) 3. Place up to two layer of glass media on front perforated sections in front of burner (Figure 47) 4. Place an even layer of glass over burner 5.
  • Page 60 Innovative Hearth Products Operation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 Installing and removing the glass door WARNING • Do not attempt to substitute the materials used on these doors, or replace cracked or broken glass. • Handle this glass with extreme care! Glass is susceptible to damage—Do not scratch or handle roughly while reinstalling the glass door frame.
  • Page 61 Innovative Hearth Products Operation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 Installing the glass door 1. Visually inspect the gasket on the backside of the glass door. NOTE: The gasket surface must be clean, free of irregularities, and seated firmly. Ensure it is properly located. Make sure the bead is not rolled into the channel at the top of the door, but remains flat against the top of the glass.
  • Page 62: Maintenance

    Innovative Hearth Products Operation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 MAINTENANCE Refer to the Maintenance Schedule on Page 63 for maintenance tasks, procedures, frequency, and a listing of by whom the tasks should be performed. Always verify proper fireplace operation after servicing. WARNING Turn OFF gas and electrical power to the fireplace and allow it to cool before cleaning or servicing the appliance.
  • Page 63 Inspecting the wiring f i r e - p a r t s . c o m Refer to the wiring diagram (DRL2000 series, Page 42, DRL3500 series, Page 43). CAUTION When servicing controls, label all wires prior to disconnection. Wiring errors can cause improper and dangerous operation.
  • Page 64: Maintenance Schedule

    Innovative Hearth Products Operation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 MAINTENANCE SCHEDULE See the tables below for detailed information about required maintenance, both regular and annual. Maintenance Performed Annually—Before the Burning Season Maintenance Task Performed By Procedure Inspecting/Cleaning Burner, Logs, and Qualified Service Technician Inspect valve and ensure it is properly...
  • Page 65: Accessory Components

    Innovative Hearth Products Operation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 ACCESSORY COMPONENTS (continued) Glass Media Kits (5 lb. Bag) Tumbled River Stone Termination Guard Kits Cat. No. Model Description Cat. No. Model Description The vent termination guards may be used to minimize exposure to the hot H8412 CRSHGL-RBLK...
  • Page 66 Innovative Hearth Products Operation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 ACCESSORY COMPONENTS (continued) DRL2000 Series Only DRL2000 Series Only Unit-Mountable Rocker Switch Kit Cost Effective Solution This rocker switch kit can be installed directly in the control compartment to provide ON/OFF •...
  • Page 67: Lighting Instructions

    Innovative Hearth Products Operation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 LIGHTING INSTRUCTIONS, DRL3500 SERIES - ENGLISH FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 68 Innovative Hearth Products Operation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 LIGHTING INSTRUCTIONS, DRL3500 SERIES - FRENCH POUR PLUS DE SÉCURITÉ LIRE AVANT DE METTRE EN MARCHE AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 69 DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 LIGHTING INSTRUCTIONS, DRL2000 SERIES - ENGLISH FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 70 DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 LIGHTING INSTRUCTIONS, DRL2000 SERIES - FRENCH POUR PLUS DE SÉCURITÉ LIRE AVANT DE METTRE EN MARCHE AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 71: Troubleshooting

    Innovative Hearth Products Operation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 TROUBLESHOOTING Before troubleshooting, ensure that the fireplace main line gas shutoff valve and the wall switch are in the ON position. The following troubleshoots the fireplace only to an elementary level. For detailed remote and ignition system troubleshooting, refer to the instructions provided with the remote.
  • Page 72: Replacement Parts

    Innovative Hearth Products Operation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 REPLACEMENT PARTS Cat. No. Fireplace Model Shipping Wt. Shipping Vol. F4182 DRL2035TEN 101 lb. 9.3 cu. ft. F4183 DRL3535TEN 101 lb. 9.3 cu. ft. F4186 DRL2045TEN 126 lb. 11.9 cu.
  • Page 73 Innovative Hearth Products Operation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 DRL2035TEN DRL2045TEN DRL3535TEN DRL3545TEN DRL2055TEN DRL3555TEN Item # Description CAT No. CAT No. CAT No. CAT No. CAT No. CAT No. Glass Door Assembly F4256 F4257 F4256 F4257 F4431 F4431...
  • Page 74 Innovative Hearth Products Operation DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 SIT Valve System Components DRL2035TEN DRL2045TEN DRL3535TEN DRL3545TEN DRL2055TEN DRL3555TEN Item # Description CAT No. CAT No. CAT No. CAT No. CAT No. CAT No. Gas Valve, Stepper Hi/Lo, SIT, Natural Gas H7270 H7270 H7270...
  • Page 75: Warranty

    Innovative Hearth Products Superior Brand Gas Fireplaces, Stoves and Inserts ® 20 Year Limited Warranty THE WARRANTY Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior Brand gas fireplace, Stove or Insert ("Product") to be free from defects in materials ®...
  • Page 76 Innovative Hearth Products Installation and Operation Instructions DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces 900994-00K, 07/2021 SuperiorFireplaces.us.com Record the following important information about your fireplace: Fireplace model number Fireplace serial number Date fireplace was Installed Type of gas fireplace uses Dealer name f i r e - p a r t s .

Table of Contents

Save PDF