Advertisement

Quick Links

P/N 900077-00 Rev. E 01/2018
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 900077-01.
P900077-00
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future
reference.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only)
or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit
is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d'autres gaz, sauf si une trousse de conversion est utilsée.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instruc-
tions.
• If you cannot reach your gas supplier, call the
fire department.
- Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
Installation and Operation Instructions
DRL6500 Direct-Vent Gas Fireplaces
Featuring Infini-Flame
Models
PFS
®
C
US
Report No. F14-108
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour
consultation ultérieure.
Technology
TM
DRL6542TEN
AVERTISSEMENT:
RISQUED'INDENDIE OU D'EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d'entraîner des blessures graves, la mort
ou des dommages matériels.
- Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où
vous trouvez.
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L'installation et l'entretien doivent être assurés par
un installateur ou un service d'entretien qualifié
ou par le fournisseur de gaz.
DRL6554TEN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DRL6500 and is the answer not in the manual?

Questions and answers

Summary of Contents for Superior Fireplaces DRL6500

  • Page 1 Installation and Operation Instructions DRL6500 Direct-Vent Gas Fireplaces Featuring Infini-Flame Technology P/N 900077-00 Rev. E 01/2018 Models Ce manuel est disponible en francais, simplement ® en faire la demande. Numéro de la pièce 900077-01. DRL6542TEN DRL6554TEN Report No. F14-108 P900077-00 INSTALLER: Leave this manual with the appliance.
  • Page 2: General Information

    Innovative Hearth Products General Information DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 SAFETY AND YOUR FIREPLACE See attached color flyer for proper color representation DANGER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS.
  • Page 3 Innovative Hearth Products General Information DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 La sécurité et Safety and Your Seguridad y su votre foyer Fireplace chimenea All parts of your ¡Todas las partes de la Toutes les parties de votre IHP fireplace get...
  • Page 4: Important Safety Information

    Innovative Hearth Products General Information DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 IMPORTANT SAFETY INFORMATION Important Safety Informa- L’information de sûreté Información importante de tion importante seguridad 1. WARNING: Do not operate appliance 1. AVERTISSEMENT. Ne pas utiliser l’appareil 1. ADVERTENCIA: No opere el artefacto con el with the glass front removed, cracked, si le panneau frontal en verre n’est pas en...
  • Page 5: Table Of Contents

    Innovative Hearth Products General Information DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 THANK YOU FOR YOUR PURCHASE. WE APPRECIATE YOUR BUSINESS! Please carefully read and follow all instructions in this manual. Pay special attention to all warnings and safety information. Following these safety, care, and operation instructions will help ensure many years of dependable and enjoyable service from your fireplace.
  • Page 6: Fireplace Installation, Operation, And Maintenance Notices

    Innovative Hearth Products General Information DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 APPLIANCE INSTALLATION, SERVICE, AND MAINTENANCE NOTICES WARNING Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
  • Page 7 Innovative Hearth Products General Information DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 APPLIANCE OPERATION NOTICES These fireplaces are vented gas appliances. Do not burn wood or other material in these appliances. These appliances are designed to operate on natural gas or propane gas only. The use of other fuels or combinations of fuels will degrade the performance of this system and may be dangerous.
  • Page 8: Packaging List

    Optional accessories • Surround kit • Bezel kit • Power vent kit (Requires DRL6500 power vent adaptor kit) • Gas conversion kit • Glass Media Kits - Reflective Blue, Platinum, Goldfinger, and Copper INTRODUCTION These vented gas fireplace heaters are sealed combustion, air-circulating gas fireplaces designed for residential, manufactured home, and commercial applications.
  • Page 9: Gas Pressure

    Innovative Hearth Products General Information DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 Approved Vent Components These fireplaces are designed, tested and listed for operation and installation with the following vent components only: • Secure Vent Direct-Vent System Components, ® •...
  • Page 10 Innovative Hearth Products General Information DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 Figure 1 - Electronic Gas Valve Green Wire (from DFC Wire Harness) Connect GTMS Manifold (OUT) wire harness Test Port Inlet (IN) Test Port Pressure Regulator Tower Orange Wire...
  • Page 11: Requirements For The Commonwealth Of Massachusetts

    Innovative Hearth Products General Information DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 Orifice Sizes—Sea Level to High Altitude These fireplaces are tested and approved for installation at elevations of 0–4500 ft (0–1372 m) above sea level using the standard burner orifice sizes (Table 5). For elevations above 4500 ft, contact your gas supplier or qualified service technician.
  • Page 12: Manufactured Home Requirements

    Innovative Hearth Products General Information DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 MANUFACTURED HOME REQUIREMENTS This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. Cet appareil peut être installé dans une maison préfabriquée (mobile) déjà installée à demeure si les règlements locaux le permettent.
  • Page 13: Vent Termination Clearances

    Innovative Hearth Products General Information DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 VENT TERMINATION CLEARANCES The following vent termination figures and charts should be used. Any installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CAN/CGA-B149.1.
  • Page 14 Innovative Hearth Products General Information DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 Table 7 - Horizontal vent termination clearances for buildings with combustible and noncombustible exteriors Inside Corner Outside Corner Recessed Location See Table 6 Fixed Balcony with No Side Wall...
  • Page 15: Minimum Clearances To Combustibles

    Innovative Hearth Products General Information DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 MINIMUM CLEARANCES TO COMBUSTIBLES Fireplace And Vent Clearances The fireplace is approved with zero clearance to combustible materials on all sides (Table 8), with the following exceptions: •...
  • Page 16: Wall Finishes / Surrounds / Mantels

    Innovative Hearth Products General Information DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 Wall Finishes / Surrounds / Mantels Clearances to combustible mantels vary according to mantel depth (Figure 6). Mantels constructed of non-combustible material may be installed at any height above the appliance opening; however, do NOT allow anything to hang below the top edge of the fireplace door.
  • Page 17: Installation Installation Sequence

    Innovative Hearth Products Installation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 INSTALLATION SEQUENCE The typical sequence of installation is outlined below; however, each installation is unique and may result in variations to the steps described. See the pages referenced in the following steps for detailed instructions.
  • Page 18: Construct The Fireplace Framing

    Innovative Hearth Products Installation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 Construct the Fireplace Framing IMPORTANT! BEFORE YOU BEGIN FRAMING, DETERMINE WHETHER YOU WILL BE INSTALLING THE FIREPLACE AS A CLEAN FACE UNIT OR USING A SURROUND AND BEZEL. SEE PAGES 43 AND 44. WE STRONGLY RECOMMEND WHEN THE FIREPLACE IS FRAMED WITH A 1/2”...
  • Page 19 Innovative Hearth Products Installation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 NOTE: Fireplace is designed for 1” thickness of non combustible board on the face of the unit. If the finished surface is to match a thinner finish material the unit must be recessed up to 1/2”...
  • Page 20: Route The Gas Supply Line Into The Fireplace

    Innovative Hearth Products Installation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 Prepare the Fireplace Top Spacers 1. The two (2) 9-3/8” standoff spacers on top of the fireplace cabinet are shipped flat (Figure 8). 2. Bend the standoffs as shown (Figure 8).
  • Page 21: Vent System Preparation

    Innovative Hearth Products Installation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 Proper Sizing of Gas Line Properly size and route the gas supply line from the supply regulator to the area where the appliance is to be installed per requirements outlined in the National Fuel Gas Code, NFPA 54—latest edition (USA) or CAN/CGA-B149.1—latest edition (Canada).
  • Page 22 Innovative Hearth Products Installation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 Figure 12 - When to use a vent restrictor Figure 13 - Vent restrictor installation, Top vent No Restrictor Base Position 1 Position 2 U-Shaped 60 ft Maximum vertical run...
  • Page 23 Innovative Hearth Products Installation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 Connecting the vent pipe Secure Vent SV4.5 direct-vent system components are unitized concentric pipe components featuring positive twist ® lock connections (Figure 18 and Figure 19). All of the fireplaces covered in this document are fitted with collars having locking inclined channels.
  • Page 24 Innovative Hearth Products Installation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 Table 17 - Vent Section Length Nominal Section Nominal Section Length Length (in.) (in.) Net Section Length 10.5 22.5 34.5 46.5 Net Section Length (in.) 10.5 22.5 34.5 46.5 (in.)
  • Page 25: Install The Vent System

    Innovative Hearth Products Installation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 Clearance to combustibles Maintain the minimum clearance to combustibles (e.g., framing, attic, ceiling insulation, etc.). For all vertical runs: • 1” (26 mm) from all sides NOTE: Attic insulation shield (H3908) must be installed when blown or loose-fill insulation is used, and is recommended for all attic installations.
  • Page 26 Innovative Hearth Products Installation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 Vertical (Offset) Installation 1. Analyze the vent route and determine the number of vent sections and elbows required—See Effective Vent Length on Page 19 for more information. Plan the venting so that a joint does not occur in the ceiling or roof joists.
  • Page 27 Innovative Hearth Products Installation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 8. Continue installation of horizontal/inclined sections—Continue with the installation of the straight vent sections in horizontal/inclined run. Install support straps every 5 ft (1.52 m) along horizontal/inclined vent runs using conventional plumber’s tape.
  • Page 28 Innovative Hearth Products Installation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 Vertical Vent Figures/Tables NOTE: If the parameters of your vent run fall outside the parameters described herein, consider installing the Power Vent Kit. NOTE: Rise per foot run ratios are acceptable all the way to level. For best results, maintain the horizontal/inclined run in a straight (no dips), slightly elevated plane of approximately 1/4”...
  • Page 29 Innovative Hearth Products Installation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 Table 19 - Top Vent—Two 90° Elbows Table 20 - Top Vent—Three Elbows Vertical Firestop/ Spacer Horizontal Firestop/ Vertical Firestop/ Spacer Spacer  Horizontal Firestop/  Spacer  ...
  • Page 30 Innovative Hearth Products Installation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 Install the Horizontal Termination Vent System These instructions should be used as a guideline and do not supersede local codes in any way. Install venting according to local codes, these instructions, the current National Fuel Gas Code (ANSI-Z223.1) in the USA or the current standards of CAN/CGA-B149.1 in Canada.
  • Page 31 Innovative Hearth Products Installation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 NOTE: Attic insulation shield (H3908) must be installed when blown or loose-fill insulation is used, and is recommended for all attic installations. 7. Maintain 1” (26 mm) clearance to combustibles, framing members, and attic or ceiling insulation when running vertical chimney sections.
  • Page 32 Innovative Hearth Products Installation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 Figure 25 - Installing the Horizontal Termination To help minimize water infiltration Typical Firestop/Spacer (SV4.5HF) shown it is recommended that the Fire- Termination on the exterior side of the wall. It Shown stop/ Spacer (SV4.5HF) be installed...
  • Page 33 Innovative Hearth Products Installation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 Table 21 - Venting Components Required for Various Exterior Wall Thicknesses, when using Typical Termination Kits Vent Components Required Exterior Wall Thickness Termination Kit Only 6 to 9-1/4” (152 to 235 mm) Termination Kit and 6”...
  • Page 34 Innovative Hearth Products Installation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 Table 23 - Top Vent—Two 90° Elbows Maximum total H Minimum total V Horizontal Horizontal Firestop/ Termination  feet meters feet meters Spacer 0.610 0.305 1.372 0.914 1.829 1.220 2.286...
  • Page 35 Innovative Hearth Products Installation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 Vertical or Horizontal Venting Using Secure Flex Kits and Components ® Secure Flex venting kits and components may be used in any other vent installation where rigid Secure Vent ®...
  • Page 36: Complete The Field Wiring

    Innovative Hearth Products Installation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 e. Slide the gear clamp down and tighten it fully to secure the flexible vent to the adaptor outer collar approximately 3/4” from the end of the flexible vent.
  • Page 37 Innovative Hearth Products Installation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 Figure 29 - Wiring Diagram—Electronic Gas Valves - SIT ProFlame II IPI Pilot Flame Sensor Schematic Representation Only Spark Electrode COLOR CODE: B = BLACK Pilot Tube BB = BROWN W/BLACK STRIPE...
  • Page 38: Optional: Wire And Install The Power Vent

    Innovative Hearth Products Installation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 WARNING Electronic models of these appliances are equipped with a three-prong (grounding) plug utilized in connecting the electronic components to the junction box in the lower compartment. This grounding plug provides protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle.
  • Page 39: Optional: Install The Modesty Panel

    Innovative Hearth Products Installation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 2. Connect the flare fitting on the flex-line to the shutoff valve. Tighten by hand, and then use a pipe wrench to tighten completely, 1/4-turn at a time. Figure 32 - Control Compartment...
  • Page 40: Install The Glass Media

    Innovative Hearth Products Installation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 3. To light the burner, turn ON the wall or remote control switch. Ensure the igniter lights the pilot. The pilot flame should engulf the flame rod (Figure 34).
  • Page 41 Innovative Hearth Products Installation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 CAUTION • Soot will be produced if the air shutter is closed too much. Any damage due to sooting, resulting from improperly setting the air shutter, is not covered under the warranty.
  • Page 42 Innovative Hearth Products Installation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 Figure 37 - Flame Appearance Table 26 - Main Burner Shutter Opening—Factory Setting Models Natural Gas Propane 1/16” 1/8” (2 mm) (4 mm) NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 43: Install The Finishing Materials

    Innovative Hearth Products Installation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 Install the Finishing Materials NOTE: See Cold Climate Insulation on Page 11 and Vent Termination Clearances on Page 13. 1. Complete finished interior wall. Maintain a minimum 1” (26 mm) clearance from the door frame outer edge to any finish material.
  • Page 44 Innovative Hearth Products Installation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 Figure 39 - Noncombustible Material with Cleanface Finish— Figure 40 - Noncombustible Material with Surround and Profile View Bezel—Profile View Insulation and combustible Min. 1" Min. 3" Insulation and combustible Min.
  • Page 45: Initialize The Remote Control System

    Innovative Hearth Products Installation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 Figure 41 - Noncombustible Material with Bezel and Barrier One (1) Top non -combustible board Clean Clean Face Frame Face Frame (removed first) (removed first) Surround mounting Bezel and Barrier...
  • Page 46 Innovative Hearth Products Installation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 Attach the Safety-in-Operation Warning Labels 1. Attach the furnished safety instruction labels at all fireplace operation and control points (Page 47). NOTE: The installer MUST ensure these warnings are properly attached during installation. The warning labels are a critical means of informing consumers of safe operation practices.
  • Page 47: Attach The Safety-In-Operation Warnings

    Innovative Hearth Products Installation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 INSTALLER INSTRUCTIONS - ATTACHING SAFETY IN OPERATION WARNINGS It is the installer’s responsibility to ensure these warnings are properly affixed during installation. These warning labels are a critical step in informing consumers of safe operation of this appliance.
  • Page 48: Installation Accessories

    Innovative Hearth Products Installation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 INSTALLATION ACCESSORIES IMPORTANT NOTE: The installation accessories shown in this section are part of the safety agency listing for the product models represented in this manual. Table 27 - Listed Secure Vent Components (NOTE: Small Square Terminations are for 42”...
  • Page 49 Innovative Hearth Products Installation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 Table 27 - Listed Secure Vent Components ® Catalog Number Model Description Catalog Number Model Description Through Wall Shield Kit (to Attic Insulation Shield shield direct-vent H5816 SV4.5-TWSK10 H3908...
  • Page 50: Gas Conversion Kits

    Innovative Hearth Products Operation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 GAS CONVERSION KITS WARNING This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion, or the production of carbon monoxide may result;...
  • Page 51 Innovative Hearth Products Operation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 Installing Gas Conversion Kits WARNING The gas supply shall be shut OFF prior to disconnecting the electrical power, before proceeding with the conversion. AVERTISSEMENT Avant d’effecteur la conversion, coupez d’abord l’alimentation en gaz, ensuite, coupez l’alimentation electrique.
  • Page 52 Innovative Hearth Products Operation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 12. Make stepper motor and valve electrical connections. 13. Remove the pilot hood assembly to access the hex pilot orifice (Figure 45). Remove and replace the pilot orifice with the one provided with the kit. Exercise extreme care to prevent damage to or breakage of the igniter assembly.
  • Page 53: Operation

    Innovative Hearth Products Operation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 OPERATION WARNING Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at-risk individuals in the house.
  • Page 54 Innovative Hearth Products Operation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 HOMEOWNER’S INSTRUCTIONS - ATTACHING SAFETY IN OPERATION WARNINGS ATTACHING SAFETY IN OPERATION WARN- APPOSITION DES MISES EN GARDE RELATIVES À COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD INGS LA SÉCURITÉ D’UTILISATION EN OPERACIÓN...
  • Page 55 Innovative Hearth Products Operation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 Burn-in Period The first few times this fireplace is operated, there will be an odor from the curing of paint and the burning off of the lubricants used in the manufacturing process. Depending on usage, the burn-in period may take a few hours or a few days.
  • Page 56 Innovative Hearth Products Operation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 To light the fireplace in a power outage: 1. Confirm that batteries are installed in the battery pack. 2. Set the unit-mounted switch, or wall switch to the ON Position.
  • Page 57 Innovative Hearth Products Operation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 Figure 48 - Remote Control Transmitter Display Child Safety Lock-Out Transmission Low Battery Alarm Thermostat Room OFF/ON/SMART Temperature Set Point Temp./Level/State Fan Control Flame On Light On Maximum Level...
  • Page 58 Innovative Hearth Products Operation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 Optional Lighting Control Turning OFF the fireplace with the wall switch will NOT turn OFF the lighting (if installed). To turn OFF these functions, use the remote control before turning OFF the fireplace with the wall switch receiver.
  • Page 59 Innovative Hearth Products Operation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 Installing and removing the glass door WARNING • Do not attempt to substitute the materials used on these doors, or replace cracked or broken glass. • Handle this glass with extreme care! Glass is susceptible to damage—Do not scratch or handle roughly while reinstalling the glass door frame.
  • Page 60 Innovative Hearth Products Operation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 Installing the glass door 1. Visually inspect the gasket on the backside of the glass door. NOTE: The gasket surface must be clean, free of irregularities, and seated firmly. Ensure it is properly located.
  • Page 61: Maintenance

    Innovative Hearth Products Operation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 MAINTENANCE Refer to the Maintenance Schedule on Page 63 for maintenance tasks, procedures, frequency, and a listing of by whom the tasks should be performed. Always verify proper fireplace operation after servicing.
  • Page 62 Innovative Hearth Products Operation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 Inspecting the glass gasket Visually inspect the gasket on the backside of the glass door. The gasket surface must be clean, free of irregularities, and seated firmly. Cleaning the control compartment Keep the control compartment clean by vacuuming or brushing it out at least twice a year.
  • Page 63 Innovative Hearth Products Operation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 MAINTENANCE SCHEDULE See the tables below for detailed information about required maintenance, both regular and annual. Maintenance Performed Annually—Before the Burning Season Maintenance Task Performed By Procedure Inspecting/Cleaning Burner/valve, Panels,...
  • Page 64 Innovative Hearth Products Operation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 Glass Media Kits One glass media kit (5 lb bag) is required with Designer style floors. Reflection style floors do not use glass media. Glass Media Catalog Model Description...
  • Page 65: Optional Accessory Components

    Innovative Hearth Products Operation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 OPTIONAL ACCESSORY COMPONENTS Surround/Bezel Kits Surround Kits Catalog No. Model No. Description F2259 CS-BLS-RAP42 Black Satin, 42” models F2256 CS-BLS-RAP54 Black Satin, 54” models Bezel Kits Catalog No. Model No.
  • Page 66: Lighting Instructions

    Innovative Hearth Products Operation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 LIGHTING INSTRUCTIONS - ENGLISH FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 67 Innovative Hearth Products Operation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 LIGHTING INSTRUCTIONS - FRENCH POUR PLUS DE SÉCURITÉ LIRE AVANT DE METTRE EN MARCHE AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 68: Troubleshooting

    Innovative Hearth Products Operation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 TROUBLESHOOTING Before troubleshooting, ensure that the fireplace main line gas shutoff valve and the wall switch are in the ON position. The following troubleshoots the fireplace only to an elementary level. For detailed remote and ignition system troubleshooting, refer to the instructions provided with the remote.
  • Page 69: Replacement Parts

    Innovative Hearth Products Operation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 REPLACEMENT PARTS Contact an IHP dealer to obtain any of these parts. Contact IHP for the phone number of your nearest IHP dealer. Installer Replacement Parts 42” 54” Description...
  • Page 70 Innovative Hearth Products Operation DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 Replacement Parts Remote Power 120V Homeowner Replacement Parts 42” 54” Description Catalog Number Catalog Number Remote Control Transmitter Kit H8753 H8753 Glass Door H8799 H8431 Top Baffle H8787 H8583...
  • Page 71: Warranty

    Innovative Hearth Products Superior Brand Gas Fireplaces, Stoves and Inserts ® 20 Year Limited Warranty THE WARRANTY Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior Brand gas fi replace, Stove or Insert ("Product") to be free from defects in materials ®...
  • Page 72 Innovative Hearth Products Installation and Operation Instructions DRL6500 Linear Direct-Vent Gas Fireplaces 900077-00, 01/2018 SuperiorFireplaces.us.com Record the following important information about your fireplace: Fireplace model number Fireplace serial number Date fireplace was Installed Type of gas fireplace uses Dealer name...

This manual is also suitable for:

Drl6542tenDrl6554ten