Superior Fireplaces DRT35STDMN Installation And Operation Instruction Manual

Superior Fireplaces DRT35STDMN Installation And Operation Instruction Manual

See-through and peninsula direct-vent gas fireplaces
Table of Contents

Advertisement

Quick Links

P/N 900300-00 REV. C 01/2018
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 900300-02.
P900300-00
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future
reference.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only)
or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit
is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d'autres gaz, sauf si une trousse de conversion est utilsée.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instruc-
tions.
• If you cannot reach your gas supplier, call the
fire department.
- Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
Installation and Operation Instructions
DRT35ST and DRT35PF See-Through and Peninsula
Direct-Vent Gas Fireplaces
Models
PFS
®
C
US
Report No. F14-165
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour
consultation ultérieure.
DRT35STDMN
DRT35STDMP
DRT35STDEN
AVERTISSEMENT:
RISQUED'INDENDIE OU D'EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d'entraîner des blessures graves, la mort
ou des dommages matériels.
- Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où
vous trouvez.
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L'installation et l'entretien doivent être assurés par
un installateur ou un service d'entretien qualifié
ou par le fournisseur de gaz.
DRT35PFDMN
DRT35PFDMP
DRT35PFDEN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DRT35STDMN and is the answer not in the manual?

Questions and answers

Summary of Contents for Superior Fireplaces DRT35STDMN

  • Page 1 DRT35ST and DRT35PF See-Through and Peninsula Direct-Vent Gas Fireplaces P/N 900300-00 REV. C 01/2018 Models Ce manuel est disponible en francais, simplement en faire la demande. Numéro de la pièce 900300-02. DRT35PFDMN DRT35STDMN ® DRT35PFDMP DRT35STDMP DRT35PFDEN DRT35STDEN Report No. F14-165 P900300-00 INSTALLER: Leave this manual with the appliance.
  • Page 2 Innovative Hearth Products Installation and Operation Instructions DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 SAFETY AND YOUR FIREPLACE See attached color flyer for proper color representation DANGER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS.
  • Page 3 Installation and Operation Instructions Innovative Hearth Products DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 La sécurité et Safety and Your Seguridad y su votre foyer Fireplace chimenea All parts of your ¡Todas las partes de la Toutes les parties de votre IHP fireplace get chimenea IHP se ponen foyer IHP deviennent...
  • Page 4: Table Of Contents

    Innovative Hearth Products Installation and Operation Instructions DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 TABLE OF CONTENTS GENERAL INFORMATION PACKAGING Packaging .........Page 4 The assembled vented gas fireplace heater is WARNING Introduction ........Page 4 packaged with: General Information ......Page 4 1 - the logs are packaged in a carton located Requirements for the Young children should be care-...
  • Page 5 Innovative Hearth Products Installation and Operation Instructions DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 NOTE: Installation and repair should be done Efficiencies % WARNING by a qualified service person. The appliance Natural Gas Propane should be inspected before use and at least Improper installation, adjust- Models AFUE...
  • Page 6: Commonwealth Of Massachusetts

    Innovative Hearth Products Installation and Operation Instructions DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 Input (BTU) Gas Valves (all models) The appliance must be isolated from the Pilot Adjustment Main Gas Control Knob gas supply piping system by closing its Screw OFF/PILOT/ON Models...
  • Page 7: Cold Climate Insulation

    Installation and Operation Instructions Innovative Hearth Products DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 COLD CLIMATE INSULATION For cold climate installations, seal all cracks around your appliance with noncombustible material and wherever cold air could enter the room. It is especially important to insulate outside chase cavity between studs and under Vertical floor on which appliance rests, if floor is above...
  • Page 8: Vent Termination Clearances

    Innovative Hearth Products Installation and Operation Instructions DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 VENT TERMINATION CLEARANCES Vertical Vent Termination Clearances Termination Heights For Vents These instructions should be used as a Above Flat Or Sloped Roofs TERMINATION HEIGHTS FOR VENTS ABOVE guideline and do not supersede local codes FLAT OR SLOPED ROOFS Ref.
  • Page 9 Installation and Operation Instructions Innovative Hearth Products DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 EXTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS Inside Corner Outside Corner Recessed Location See Figure 5 Fixed Balcony with No Side Wall Balcony with Perpendicular Side Wall Openable Fixed Closed Closed...
  • Page 10 Innovative Hearth Products Installation and Operation Instructions DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 MINIMUM CLEARANCES TO COMBUSTIBLES Hearth Extension - A hearth extension is not required with this appliance. If a hearth exten- Appliance And Vent Clearances sion is used, do not block the lower control compartment door.
  • Page 11: Detailed Installation Steps

    Installation and Operation Instructions Innovative Hearth Products DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 WARNING MINIMUM CLEARANCES Inches (millimeters) Sides 1/2" (13) Failure to position the parts in accordance with these 0 (0) from Spacers Or Dimples ** diagrams or failure to use only parts specifically Top of Appliance 5 (127) approved with this appliance may result in property...
  • Page 12: Typical Installation Sequence

    Innovative Hearth Products Installation and Operation Instructions DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 Bend up the outer pair for 1/2" materials and Step 11. (Page 35) Adjust burner to ensure the inner pair for 5/8" materials. Bend out the proper flame appearance.
  • Page 13: Fireplace And Framing Specifications

    Installation and Operation Instructions Innovative Hearth Products DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 DRT35ST SPECIFICATIONS Natural Gas BTU Input 30,000 Propane Gas BTU Input 28,000 ***This dimension does not include the addition 4-1/2" Inner / Co-axial DV Vent Size of drywall to the inside of **20-3/4 7-1/2"...
  • Page 14 Innovative Hearth Products Installation and Operation Instructions DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 DRT35PF Fireplace Framing Specifications SPECIFICATIONS Notes: • Inches (millimeters) • Minimum Framing Stud Size is 2 x 4 Natural Gas BTU Input 30,000 • See side views of fireplace below for ***This dimension does gas line inlet location options.
  • Page 15: Step 2. Routing Gas Line

    Installation and Operation Instructions Innovative Hearth Products DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 Step 2. ROUTING GAS LINE IMPORTANT: If propane is used, be aware that Schedule 40 if tank size is too small (i.e. under 100-lbs, if Black Iron Pipe Route a 1/2"...
  • Page 16: Step 4. Install The Venting System

    Innovative Hearth Products Installation and Operation Instructions DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 Step 4. INSTALL THE VENT SYSTEM CROSS SECTION Securing Screws Top Vent Vent Seal Cap General Information (OUTSIDE of Appli ance) These instructions should be used as a guideline and do not supersede Insulation local codes in any way.
  • Page 17: Vertical Termination Systems

    Installation and Operation Instructions Innovative Hearth Products DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 VERTICAL TERMINATION SYSTEMS (ROOF) i t c i t c See Figure 19 and Figures 29 through 34 on i t c Pages 20, 21 and 22 and their associated i t c Vertical Vent Tables which illustrate the various vertical venting configurations that are possible...
  • Page 18 Innovative Hearth Products Installation and Operation Instructions DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 Vertical (Offset) Installation B. Attach vent components to appliance - C. Attach vent components to each other - Other vent sections may be added to the previously Secure Vent SV4.5 direct vent system compo- ®...
  • Page 19 Installation and Operation Instructions Innovative Hearth Products DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 E. Support the vertical vent run sections - H. Frame roof opening - Identify location for NOTE: Proper venting support is very important. vent at the roof. Cut and/or frame opening per The weight of the vent must not be supported Roof Framing Chart and Figure 25.
  • Page 20: Vertical Vent Tables And Figures

    Innovative Hearth Products Installation and Operation Instructions DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 VERTICAL VENT FIGURES/TABLES Table A NOTE: Secure Vent (rigid vent pipe) is shown ® in the figures; Secure Flex (flexible vent pipe) V Minimum ® H Maximum may also be used.
  • Page 21 Installation and Operation Instructions Innovative Hearth Products DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 VERTICAL VENT FIGURES / TABLES (CONTINUED) Table C Maximum H Maximum V Minimum feet (meter) feet (meter) feet (meter) Ceiling Firestop / (1.524) (0.610) (0.305) Spacer (SV4.5VF) (3.048) (1.219)
  • Page 22: Horizontal Termination System

    Innovative Hearth Products Installation and Operation Instructions DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 HORIZONTAL (OUTSIDE WALL) Support TERMINATION SYSTEM Horizontal / Inclined Run Building Brackets Support Figures 34, and Figures 37 to 42 on Pages Framing SV4.5HT-2 24 to 26 and their associated Horizontal Vent Termination SV4.5E90 Table illustrate the various horizontal venting...
  • Page 23 Installation and Operation Instructions Innovative Hearth Products DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 J. Assemble vent run to exterior wall - If not To help minimize water infiltration it Typical previously measured, locate the center of the is recommended that the Firestop/ Termination vent at the exterior wall.
  • Page 24: Horizontal Vent Tables And Figures

    Innovative Hearth Products Installation and Operation Instructions DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 HORIZONTAL VENT FIGURES/TABLES Table F NOTE: Secure Vent components (rigid vent pipe and terminal) are ® shown in the figures; Secure Flex components (flexible vent pipe and ®...
  • Page 25 Installation and Operation Instructions Innovative Hearth Products DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 HORIZONTAL VENT FIGURES/TABLES (continued) Table G V Minimum Maximum H Maximum feet (meter) feet (meter) feet (meter) (1.524) (0.610) (0.305) (3.048) (1.219) (0.610) (4.572) (1.829) (0.914) Wall Firestop/ Spacer (SV4.5HF)
  • Page 26 Innovative Hearth Products Installation and Operation Instructions DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 HORIZONTAL VENT FIGURES/TABLES (continued) When using Secure Flex , use ® Example: If 20 feet total (H+H Wall Firestop / Spacer Firestop / Spacer SF4.5VF horizontal vent run is needed, then 4 (SV4.5HF) When using Secure Flex, use...
  • Page 27: Venting Using Flexible Vent Pipe

    Installation and Operation Instructions Innovative Hearth Products DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 VERTICAL OR HORIZONTAL VENTING USING SECURE FLEX ® KITS AND COMPONENTS FLEX VENT NOTE: OUTER PIPE IS PULLED AWAY TO Secure Flex venting kits and components may ®...
  • Page 28: Step 5. Field Wiring

    Innovative Hearth Products Installation and Operation Instructions DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 Step 5. FIELD WIRING Refer to Section A for millivolt appliances and Install OFF/ON Switch Section B for electronic appliances. The gas (millivolt models) valve is set in place and pre-wired at the factory CAUTION 1.
  • Page 29: Step 6. Optional Blower Kit Wiring

    Installation and Operation Instructions Innovative Hearth Products DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 Step 6. WIRING - OPTIONAL FORCED AIR Install the blower kits according to the instal- BLOWER KIT lation instructions provided with the kits. See Ground Wire Figure 13 on Page 13 showing where blower Connection should be located on unit.
  • Page 30: Step 7. Connecting Gas Line

    Innovative Hearth Products Installation and Operation Instructions DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 The gas controls can be found behind the hinged TEST ALL CONNECTIONS FOR GAS LEAKS Step 7. CONNECTING GAS LINE drop-down panel. (FACTORY AND FIELD): Make gas line connections.
  • Page 31: Step 8. Verifying Appliance Operation

    Installation and Operation Instructions Innovative Hearth Products DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 Step 8. VERIFYING APPLIANCE OPERA- When first lighting the appliance, it will take a The flame should project 1" (26 mm) beyond few minutes for the line to purge itself of air. the hood at all three ports (see Figure 52).
  • Page 32 Innovative Hearth Products Installation and Operation Instructions DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 Bottom View of Logs (in packaging) LOG SET - IDENTIFICATION LOG SET Catalog Number H3210 * Item Description Log, Center Log, Left Rear Log, Right Log, Top Center Log, Top/Left Log, Top/Right...
  • Page 33: Step 9. Installing Logs

    Installation and Operation Instructions Innovative Hearth Products DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 7. Place Log (B) as shown in Figure 57. Step 9. INSTALL VERMICULITE, GLOWING EMBERS AND LOGS Position Log (B) Against The Back Of NOTE: Turn off all electricity to the appliance before you install vermiculite, The Grate Here embers and logs.
  • Page 34 Innovative Hearth Products Installation and Operation Instructions DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 10. Place Log (E) as shown in Figure 60. WARNING Position The Round End Of Log (E) Against The Notch Of • DO NOT attempt to install the logs until the appli- Log (D) Here.
  • Page 35: Step 10. Remove/Install Glass Door

    Installation and Operation Instructions Innovative Hearth Products DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 Step 10. REMOVING AND INSTALLING Step 11. BURNER ADJUSTMENTS Removing Glass Enclosure Panel THE GLASS DOOR (see Figure 62) Flame Appearance and sooting To access the glass door securing latches, first Proper flame appearance is a flame which is remove the hood by pulling firmly straight away WARNING...
  • Page 36 Innovative Hearth Products Installation and Operation Instructions DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 Burner Adjustment • If flame appears weak or sooty, adjust 1. Refer to Figure 63 for proper flame ap- the air shutter, incrementally, to a more pearance.
  • Page 37: Step 12. Hood Installation

    Installation and Operation Instructions Innovative Hearth Products DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 Decrease Shutter Opening In This Direction Combustible Wall This Area Must Remain Framing 3" (77 mm) Clear of Combustible Materials Combustible Finished Wall Orifice Materials 1"...
  • Page 38: Step 13. Attaching Safety-In-Operation Warnings

    Innovative Hearth Products Installation and Operation Instructions DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 STEP 13. ATTACHING SAFETY-IN-OPERATION WARNINGS It is the installers responsibility to ensure these warnings are properly affixed during installation. These warning labels are a critical step in informing consumers of safe operation of this appliance.
  • Page 39: Installation Accessories

    Installation and Operation Instructions Innovative Hearth Products DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 INSTALLATION ACCESSORIES IMPORTANT NOTE: The installation accessories shown in this section are part of the safety agency listing for the product models represented in this manual. Listed Secure Vent Components ®...
  • Page 40 Innovative Hearth Products Installation and Operation Instructions DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 Listed Secure Vent Components Listed Secure Flex Components ® ® Cat. # Model Description Cat. # Model Description These termination kits include firestop/spacer, gear clamps and flex adaptor. 17M52 SV4.5HGS-1 Te r m i n a t i o n G u a r d ,...
  • Page 41: Gas Conversion Kits

    Installation and Operation Instructions Innovative Hearth Products DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 GAS CONVERSION KITS Natural Gas to Propane Gas Conversion Kits WARNING Fireplace Cat. No. Model No. (model) This conversion kit shall be installed by a qualified service agency in ST/PF-DMN H3360 accordance with the manufacturer’s instructions and all applicable codes...
  • Page 42 Innovative Hearth Products Installation and Operation Instructions DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 Gas Valve Pan Burner Assembly Air Shutter Adjustment Lever Manifold Pressure Test Port Venturi Tube Slotted Valve Access Side of Fireplace Spring Adjusting Firebox Subfloor Screw Figure 66 Figure 69...
  • Page 43 Installation and Operation Instructions Innovative Hearth Products DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 b. Install the burner as shown in Figure 72. Step 9. Reassemble the remaining components by reversing the procedures outlined in the Ensure that the arm of the venturi of the burner preceding steps.
  • Page 44 Innovative Hearth Products Installation and Operation Instructions DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 GENERAL INFORMATION OPERATION CONGRATULATIONS! WARNING Children and adults should be In selecting this Innovative Hearth Products alerted to the hazards of high direct-vent gas appliance you have chosen surface temperature and should the finest and most dependable fireplace stay away to avoid burns or...
  • Page 45 Installation and Operation Instructions Innovative Hearth Products DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 NOTE: Installation and repair should be Due to high temperatures the appliance WARNING should be located out of traffic and away done by a qualified service person. The from furniture and draperies.
  • Page 46 Innovative Hearth Products Installation and Operation Instructions DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 Orifice Sizes - Sea Level to High Altitude Gas Pressure - All Models BTU Input (All Models) Tables 13 and 14 show the appliances' inlet and These fireplaces are designed as supplemental manifold gas pressure requirements: These appliances are tested and approved for...
  • Page 47: Operation/Care Of Your Appliance

    Installation and Operation Instructions Innovative Hearth Products DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 OPERATION AND CARE OF YOUR APPLIANCE WARNING Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns.
  • Page 48: Variable Flame Adjustment

    Innovative Hearth Products Installation and Operation Instructions DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 Variable Flame Height Adjustment Variable Flame Height Adjustment Inlet Pressure Port (Millivolt Appliances only) Manifold Pressure Port 1. All Millivolt appliances are equipped with a variable gas control valve. Flame height for these models may be adjusted through a range between fixed low and high settings, alternately, while the appliance is in operation.
  • Page 49: Attaching Safety In Operation Warnings

    Installation and Operation Instructions Innovative Hearth Products DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 HOMEOWNER’S INSTRUCTIONS - ATTACHING SAFETY IN OPERATION WARNINGS ATTACHING SAFETY IN OPERATION WARNINGS APPOSITION DES MISES EN GARDE RELATIVES COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD À LA SÉCURITÉ D’UTILISATION EN OPERACIÓN Your fireplace has been furnished with safety instruc- Votre foyer a été...
  • Page 50: Maintenance

    Innovative Hearth Products Installation and Operation Instructions DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 MAINTENANCE Cleaning Glass NOTE: Improper positioning of logs can create carbon build-up and will alter the performance (see Front Glass Enclosure Panel, Removal and of the appliance. (See Maintenance Schedule, Page 59) Installation on Page 9).
  • Page 51: Front Glass Enclosure Panel, Removal And Installation

    Installation and Operation Instructions Innovative Hearth Products DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 Front Glass Enclosure Panel, Removal Installing Glass Enclosure Panel WARNING and Installation (see Figure 76) Any safety screen, guard, or Retrieve the glass door. Visually inspect the WARNING barrier removed for servicing gasket on the backside of the frame.
  • Page 52 Innovative Hearth Products Installation and Operation Instructions DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 Bottom View of Logs (in packaging) LOG SET - IDENTIFICATION LOG SET Catalog Number H3210 * Item Description Log , Center Log, Left Rear Log, Right Log, Top Center Log, Top/Left Log, Top/Right...
  • Page 53 Installation and Operation Instructions Innovative Hearth Products DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 INSTALLATION STEPS: 7. Place Log (B) as shown in Figure 8. READ WARNINGS ON Page 50 BEFORE PROCEEDING Position Log (B) Against The Back Of The Grate Here 1.
  • Page 54 Innovative Hearth Products Installation and Operation Instructions DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 10. Place Log (E) as shown in Figure 11. WARNING Position The Round End Of Log (E) Against The Notch Of • DO NOT attempt to install the logs until the appli- Log (D) Here.
  • Page 55: Burner Flame Appearance/Sooting

    Installation and Operation Instructions Innovative Hearth Products DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 BURNER ADJUSTMENTS Air Shutter Adjustment Guidelines The following chart is provided to aid you in achieving the correct air shutter adjustment (QUALIFIED TECHNICIANS ONLY) • If there is smoke or soot present, first for your installation.
  • Page 56: Burner Flame Adjustments

    Innovative Hearth Products Installation and Operation Instructions DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 BURNER FLAME ADJUSTMENTS Decrease Shutter Opening MILLIVOLT Hood Igniter Rod In This Direction WARNING Thermocouple • Air shutter adjustment should only be performed by a quali- Orifice fied professional service tech- 3/8"...
  • Page 57: Wiring Diagrams

    Installation and Operation Instructions Innovative Hearth Products DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 WIRING DIAGRAMS ATTENTION: AU MOMENT DE L'ENTRETIEN DES COMMANDES, ÉTIQUETEZ TOUS LES FILS AVANT DE LES DÉBRANCHER. DES ERREURS DE CÁBLAGE Wiring diagrams are provided here for reference PEU-VENT ENTRAÎNER UN FONCTIONNEMENT INADÉQUAT ET DANGEREUX.
  • Page 58: Accessory Components

    Innovative Hearth Products Installation and Operation Instructions DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 ACCESSORY COMPONENTS Forced Air Blower Kits Cat. Model No. Description Blower, Standard 80L84 FBK-100 (single speed) Blower, Variable Speed 80L85 FBK-200 (w/wall-mounted switch) Blower, Variable Speed (w/ 80L86 FBK-250 unit-mounted switch)
  • Page 59: Maintenance Schedule

    Installation and Operation Instructions Innovative Hearth Products DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 MAINTENANCE SCHEDULE Annually (Before the onset of the Burning Season) MAINTENANCE TASK ACCOMPLISHING PERSON PROCEDURE Inspecting/Cleaning Burner, Logs Qualified Service Technician Inspect valve and ensure it is properly operating. Check piping and Controls for leaks.
  • Page 60: Lighting Instructions - Millivolt

    Innovative Hearth Products Installation and Operation Instructions DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 LIGHTING INSTRUCTIONS – MILLIVOLT GAS VALVE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 61 Installation and Operation Instructions Innovative Hearth Products DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT POUR PLUS DE SÉCURITÉ, LIRE AVANT D’ALLUMER AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 62 Innovative Hearth Products Installation and Operation Instructions DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 LIGHTING INSTRUCTIONS — ELECTRONIC FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 63: Lighting Instructions - Electronic

    Installation and Operation Instructions Innovative Hearth Products DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 INSTRUCTIONS D’ALLUMAGE — ELECTRONIC POUR PLUS DE SÉCURITÉ LIRE AVANT DE METTRE EN MARCHE AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 64: Troubleshooting Guide - Millivolt

    Innovative Hearth Products Installation and Operation Instructions DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 TROUBLESHOOTING THE MILLIVOLT GAS CONTROL SYSTEM NOTE: Before troubleshooting the gas control system, be sure external gas shut off valve (located at gas supply inlet) is in the “ON” position.
  • Page 65: Troubleshooting Guide - Electronic

    Installation and Operation Instructions Innovative Hearth Products DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 TROUBLESHOOTING THE ELECTRONIC IGNITION SYSTEM NOTE: Before troubleshooting, be sure that the appliance main line gas shut-off valve, the gas control valve and the wall switch are in the “ON”...
  • Page 66: Replacement Parts List

    Innovative Hearth Products Installation and Operation Instructions DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 REPLACEMENT PARTS LIST - ST/PF Item Cat. No. Description Where Used Item Cat. No. Description Where Used SIT Millivolt Only Misc. Replacement Parts H6286 Gas Train Assembly, NG, MV SEE THROUGH H3210 Log Set...
  • Page 67 Installation and Operation Instructions Innovative Hearth Products DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 REPLACEMENT PARTS (PENINSULA SHOWN) Complete Log Set Available Only NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 68 Innovative Hearth Products Installation and Operation Instructions DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 NOTES: NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 69: Warranty

    Innovative Hearth Products Superior Brand Gas Fireplaces, Stoves and Inserts ® 20 Year Limited Warranty THE WARRANTY Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior Brand gas fi replace, Stove or Insert ("Product") to be free from defects in materials ®...
  • Page 70 Innovative Hearth Products Installation and Operation Instructions DRT35ST and DRT35PF Direct-Vent Gas Fireplaces 900300-00, 01/2018 SuperiorFireplaces.US.com Record the following important information about your appliance: Appliance model number Appliance serial number Date appliance was Installed Type of gas appliance uses Dealer name IHP reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.

Table of Contents