Error Messages
NONFATAL FAULTS
If a nonfatal fault occurs, all functions not directly affected by the
fault continue to operate. See your authorized Stormscope dealer
as soon as possible to correct the fault.
RECOVERABLE FAULTS
A recoverable fault is one that allows the affected functions
to automatically resume proper operation after the fault goes
away. A messaging error (errors 43 through 51, 53 and 54) is
an example of a recoverable fault. Messaging errors are likely
caused by excessive noise on the communication lines, or an
MFD communications problem. These messages automatically
clear after the message is processed and therefore may appear
only briefly on the MFD.
NONRECOVERABLE FAULTS
A nonrecoverable fault allows continued operation, but without the
function affected by the fault. The affected function will not resume
proper operation until the system is turned off and repaired.
FATAL FAULTS
If a fatal fault occurs, all functions will cease to operate. In this
case, turn off the WX-500 and see your authorized Stormscope
dealer for service.