Panasonic EB-X70 Service Manual page 54

Digital cellular phone
Hide thumbs Also See for EB-X70:
Table of Contents

Advertisement

CALIBRATION PROCEDURES
9.2.2
Power Level Tables
The following tables show the measurement limits according to power level:
The values in these tables are required only if manual Tx Trim is used to trim individual channels.
EGSM 900
Output Power (dBm)
Power Level
(PL)
Nominal
5
32.25
6
31.0
7
29.0
8
27
9
25
10
23
11
21
12
19
13
17
14
15
15
13
16
11
17
9
18
7
19
5
GSM 1800
Output Power (dBm)
Power Level
(PL)
Nominal
0
29.55
1
28.0
2
26.0
3
24.0
4
22.0
5
20.0
6
18.0
7
16.0
8
14.0
9
12.0
10
10.0
11
8.0
12
6.0
13
4.0
14
2.0
15
0.0
Issue 1
Revision 0
All manuals and user guides at all-guides.com
Target
Min
Max
32.0
32.5
30.5
31.5
28.5
29.5
26.5
27.5
24.5
25.5
22.5
23.5
20.5
21.5
18.5
19.5
16.5
17.5
14.5
15.5
12.5
13.5
10.5
11.5
8.5
9.5
6.5
7.5
4.5
5.5
Target
Min
Max
29.3
29.8
27.5
28.5
25.5
26.5
23.5
24.5
21.5
22.5
19.5
20.5
17.5
18.5
15.5
16.5
13.5
14.5
11.5
12.5
9.5
10.5
7.5
8.5
5.5
6.5
3.5
4.5
1.5
2.5
-0.5
0.5
Section 9
– 52 –
GSM 1900
Output Power (dBm)
Power Level
(PL)
Nominal
0
29.25
1
28.0
2
26.0
3
24.0
4
22.0
5
20.0
6
18.0
7
16.0
8
14.0
9
12.0
10
10.0
11
8.0
12
6.0
13
4.0
14
2.0
15
0.0
Target
Min
Max
29.0
29.5
27.5
28.5
25.5
26.5
23.5
24.5
21.5
22.5
19.5
20.5
17.5
18.5
15.5
16.5
13.5
14.5
11.5
12.5
9.5
10.5
7.5
8.5
5.5
6.5
3.5
4.5
1.5
2.5
-0.5
0.5
PMCD030901C8