4. Preparation and Configuration
4.1 Material list
The unit is supplied with the following materials. Please confirm the serial number on charger
is same to that on outer carton.
NEMO battery to battery charger.
User manual.
Sensor / Ignition / RS485 (model dependent for IDX and IDDX).
4.2 Location
Please install the equipment in a clean, cool location with good ventilation.
Working temperature: -20℃~+60℃.
Storage temperature: -40℃~+85℃.
4.3 Battery type setting
Table 4-1 Switch status for battery type and charging voltage
Switch status
Battery type
OFF, OFF
OFF, ON
ON, OFF
ON, ON
NEMO series battery to battery Charger
Absorption
12V
AGM
14.6
GEL
14.2
LFP
14.4
WET
14.8
8
Charging Voltage (V)
24V
12V
29.2
13.5
28.4
13.8
28.8
13.5
29.6
13.8
Floating
24V
27
27.6
27
27.6