models and gas type verification

INTRODUCTION:
Capital's Performance Series™ Gas Ranges are tested and approved in accordance with ANSI Z21.1b-2003/CGA IR
58, 1995, Household Cooking Appliances. It is STRONGLY RECOMMENDED that this appliance be installed in
conjunction with a suitable overhead VENT HOOD. Due to the high heat output of this unit, particular attention should
be paid to the hood and ductwork installation to assure it meets local building codes.
All Performance Series™ gas ranges,
feature a Gas Cooking Surface with Gas Convection Ovens,
and Gas Infrared Broiler
MODEL #
FEATURES:
PSGR244
24" gas range w/ 4 sealed burners
PSGR304
30" gas range w/4 sealed burners
PSGR366
36" gas range w/ 6 sealed burners
PSGR364G
36" gas range w/ 4 sealed burners and griddle
PSGR364B
36" gas range w/ 4 sealed burners and BBQ
PSGR488
48" gas range w/ 8 sealed burners
PSGR486B
48" gas range w/ 6 sealed burners and BBQ
PSGR486G
48" gas range w/ 6 sealed burners and griddle
PSGR484BG
48" gas range w/ 4 sealed burners + BBQ + griddle
IMPORTANT:
A back guard must be utilized when there is
less than 12" horizontal clearance between
combustible materials and the back edge of
the range.
The Capital PERFORMANCE
SERIES™ Low Back must be ordered
separately and installed at the rear of the
range.
For island installations and other
installations with more than 12" clearance,
an optional stainless steel Island Trim
is
available
to
cover
mounting flanges.
special instructions for Massachusetts:
In the COMMONWEALTH OF MASSACHUSETTS, GAS CONNECTION MUST BE PERFORMED BY A
LICENSED PLUMBER OR GAS FITTER.
the
back-guard
GAS SUPPLY:
Natural Gas: 6-inch water column.
(14.9mb) Min., 8 inch (20mb) nominal
Propane Gas: 11-inch water column.
(27.4mb), 14 inch (37mb) maximum
ELECTRIC POWER SUPPLY:
PSGR244 model –
120 VAC, 60 HZ. 1 Ph., 10 Amp Circuit
PSGR304 model –
120 VAC, 60 Hz., 1 Ph., 10 Amp Circuit
PSGR36 models –
120 VAC, 60Hz., 1 Ph., 10 Amp Circuit
PSGR48 models –
120 VAC, 60 Hz., 1 Ph., 10 Amp Circuit
GAS TYPE VERIFICATION:
Your gas range is shipped from the factory to operate on
either natural gas or LP depending on the model ordered.
Verify that the gas being used at the installation site matches
the type of gas being used by the appliance. If the location/
job site requires a conversion from one type of gas to
another, contact the dealer where the unit was purchased or
contact CAPITAL Customer Service at 866-402-4600. The
field conversion kit for all PERFORMANCE SERIES™ ranges
and ranges is Capital model # PSGRCKN-L (Natural to LP)
or PSGRCKL-N (LP to Natural). ONLY a qualified service
technician MUST perform the field conversion.
2