17
BEFORE MAKING ELECTRICAL
CONNECTIONS
Note to Electrician: The power leads supplied with this
appliance are UL-recognized for connection to large
gauge household wiring.
The insulation of these leads is rated at temperatures
much higher than the temperature rating of household
wiring. The current carrying capacity of a conductor is
governed by the wire gauge and also the temperature
rating of the insulation around the wire.
Aluminum Wiring –
IMPROPER CONNECTION OF ALUMINUM HOUSE
WIRING TO THE COPPER LEADS CAN RESULT IN
SERIOUS PROBLEMS.
Attach copper wires to aluminum wiring using special
connectors designed and UL-listed for joining copper
to aluminum. Follow the connector manufacturer's
recommended procedure closely.
Service Loop – Leave a loop in the wires to the
cooktop so that the cooktop can be lifted 12 inches
without having to disconnect the wiring.
ELECTRICAL REQUIREMENTS*
Model #
Voltage
PP989
120/240V
120/208V
*For reference only. Verify with product rating plate.
Electrical installation kit JXCK89 may be ordered
separately and includes all the parts necessary to
connect the cooktop to typical rough-in wiring.
Installation Instructions

ELECTRICAL CONNECTIONS

WARNING:
Frequency
KW
60Hz
9.1KW
60Hz
6.9KW
Rating Plate
INSTALL 3/4 FLEXIBLE CONDUIT
18
Remove the screws holding
the wire compartment cover
and remove the cover.
Feed the power
supply leads
through the
conduit; be sure to
leave enough length
to properly connect
these leads to the
cooktop power leads.
Thread the leads
through an anti-
short bushing and
firmly seat the
bushing in the end
of the conduit.
Feed the leads
through the hole
in the wire
compartment.
As local codes
permit purchase
a listed conduit
connector suitable
for the size conduit.
Insert the conduit
through the
connector and
attach it to the
cover. Allow
enough slack to
easily attach the
wires to the
cooktop.
Note: Do not install
the cooktop without
a listed conduit
connector. The
conduit connector
should be installed
before reinstalling
the wiring cover.
When complete,
reinstall the wire
compartment cover.
25
Power Supply
Anti-Short
Conduit
Leads
Bushing
Bushing (Fully Seated)
Conduit
Connector
Conduit
Cover

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Pp989

Table of Contents