Installation of the range.
Electrical Power Supply Requirements
Recommended Electrical Outlet Locations
NOTE: Make electrical connections
on the right side of the cutout opening.
Provide Proper Electrical Supply
These ranges must be supplied with 208/240 volt,
60 Hz., and connected to an individual, properly
grounded circuit protected by a circuit breaker
or time-delay fuse (40 amp). The receptacle must
be NEMA 14-50R to accept the 4-prong plug
supplied with the range.
44
30"
4"
8"
2
1
"
4
7
"
1
2
Recommended acceptable
electrical outlet area. Orient
3"
the electrical receptacle so the
length is parallel to the floor.
Wall Mounted
Product is shipped with 4-prong
plug. Recommended outlet is a
NEMA 14-50R receptacle.
If the electrical service provided does not meet
the above specifications, it is recommended that
a licensed electrician install an approved outlet.
s
Locate the electric supply as illustrated.