  • Page 1 Operation and Maintenance Guide Document Version 1.1 Release date 2020-09-20...
  • Page 2 Note: The products, services or characteristics you purchase shall be subject to the commercial contracts and terms of Inspur Group. All or part of the products, services or features described in this document may not be within your scope of purchase or use.
  • Page 3: Preface

    NF5180M5 Operation and Maintenance Guide Preface Summarize This manual introduces the fault phenomenon of Inspur server and the corresponding diagnosis, treatment methods, upgrading and inspection guidance. According to this manual, you can carry out routine maintenance, take corresponding measures to deal with alarms and faults, understand patrol inspection related matters, and upgrade corresponding software.
  • Page 4 "Attention" does not involve personal injury. Used to highlight important/critical information, best practices, tips, etc. The "instructions" are not safety warning information and do not involve personal, equipment and environmental injury information. Inspur proprietary and confidential information Copyright Inspur Electronic Information Industry Co., Ltd.
  • Page 5: Table Of Contents

    4.3.4..Network port indicator............... ………..11 According to the phenomenon processing fault..........…..12 Power supply problem................... 12 4.4.1 4.4.2 Memory error problem.................. 13 4.4.3 Hard disk problem..................14 Upgrade............................. 15 Inspur proprietary and confidential information Copyright Inspur Electronic Information Industry Co., Ltd.
  • Page 6 Gold finger type..................27 Installation rules..................28 8.3.3 CPU maintenance..................... 29 Memory maintenance....................29 Hard disk maintenance..................... 31 8.6.1 Hard disk installation rules................. 31 Hard disk bit order..................32 8.6.2 Inspur proprietary and confidential information Copyright Inspur Electronic Information Industry Co., Ltd.
  • Page 7 NF5180M5 Operation and Maintenance Guide 8.6.3 Hard disk backplane..................34 Power supply maintenance..................37 Appendix: Environmental Protection Statement..............38 10 Supporting documents......................40 Inspur proprietary and confidential information Copyright Inspur Electronic Information Industry Co., Ltd.
  • Page 8: Safety

    Before touching the equipment, server equipment, and are prohibited from being used on other equipment. Before touching the equipment, wear anti-static overalls and anti-static gloves to prevent damage to the equipment caused by static electricity. Inspur proprietary and confidential information Copyright Inspur Electronic Information Industry Co., Ltd.
  • Page 9: Matters Needing Attention In Equipment Relocation

    It is strictly prohibited to move the equipment with electricity, and It is strictly prohibited to bring objects that may lead to danger in the relocation process. viii Inspur proprietary and confidential information Copyright Inspur Electronic Information Industry Co., Ltd.
  • Page 10: Maximum Weight Allowed To Be Carried By A Single Person

    NIOSH(National Institute for Occupational Safety and Health) HSE(Health and Safety Executive) 25/55.13 general administration of quality supervision, inspection and male: 15/33.01 quarantine of the people's republic of china female: 10/22.05 Inspur proprietary and confidential information Copyright Inspur Electronic Information Industry Co., Ltd.
  • Page 11: Processing Flow

    If problems that are difficult to determine or solve are encountered Support in the process of equipment maintenance or fault handling, and cannot be solved through the guidance of documents, please contact Inspur proprietary and confidential information Copyright Inspur Electronic Information Industry Co., Ltd.
  • Page 12: Processing Preparation

    Familiar with the process of equipment maintenance. Required reading materials The required data for daily maintenance of the server are shown in Table 3-1. Inspur proprietary and confidential information Copyright Inspur Electronic Information Industry Co., Ltd.
  • Page 13: Toolpreparation

    Electrostatic bracelet, as shown in figure 3-1. Figure 3-1 3.4.1 Hardware tools CD, U disk, keyboard, monitor, network cable, screwdriver, etc 3.4.2 Software tool FW refresh files, etc. Inspur proprietary and confidential information Copyright Inspur Electronic Information Industry Co., Ltd.
  • Page 14: Fault Diagnosis And Treatment

    When analyzing alarms, first analyze high-level alarms, such as emergency alarms and serious alarms, and then analyze low-level alarms, such as minor alarms. Troubleshooting according to the alarm xiii Inspur proprietary and confidential information Copyright Inspur Electronic Information Industry Co., Ltd.
  • Page 15: Locate The Fault According To The Indicator

    Locate the fault according to all kinds of indicators on the server panel. Figure below shows the indicators on the front panel of NF8480M5. The specific lighting meanings are shown in Table5-1. 3.5x4 NF5180M5 All indicators on front panel Table 3.5 NF8480M5 front panel indicator functions Numbering...
  • Page 16 When a fault occurs, it is always bright red. indicator Red flashes when a warning occurs 2.5x10 NF5180M5 All indicators on front panel Table 2.5x10 NF5180M5 function of each indicator lamp on the front panel Numbering Module name Functional description In the power-on state, the indicator is green.
  • Page 17: Hard Drive Status Indicator

    Table 4-2 Function Description of Hard Disk Status Indicator Numbering Name Function and description Hard disk failure Solid red: hard disk failure alarm indicator Solid Blue: Hard Disk Positioning Inspur proprietary and confidential information Copyright Inspur Electronic Information Industry Co., Ltd.
  • Page 18: Power Status Indicator

    Indicates that there is currently no data transmission 10GE Port Rate Green (solid bright) Indicates that the current Link link rate Indicator is 10G. xvii Inspur proprietary and confidential information Copyright Inspur Electronic Information Industry Co., Ltd.
  • Page 19: According To The Phenomenon Processing Fault

    1. Check the LED status of the power module and record BMC Single power module failure alarm information. Please refer to the indicator lamp for the (no output, specific status of the indicator lamp. health status xviii Inspur proprietary and confidential information Copyright Inspur Electronic Information Industry Co., Ltd.
  • Page 20: Memory Error Problem

    Replace the motherboard and power backplane to see if the problem has been resolved. Yes, processed. No, please contact Inspur technical support engineer. 4.4.2 Memory error problem For faults related to memory errors, please diagnose according to the following conditions.
  • Page 21: Hard Disk Problem

    Verify that the power supply cable and hard disk are properly recognized in the RAID installed card. Otherwise, replace RAID card, SAS cable and hard disk backplane in turn to solve the problem. Inspur proprietary and confidential information Copyright Inspur Electronic Information Industry Co., Ltd.
  • Page 22: Upgrade

    BIOS and BMC firmware, user manuals, etc. At the same time, users can also view the machine configuration information according to the machine serial number. Figure 6-1 Figure 6- 2 Inspur proprietary and confidential information Copyright Inspur Electronic Information Industry Co., Ltd.
  • Page 23 BIOS and BMC are provided with refresh methods, which can be refreshed under the system and under the Web interface. Please refer to the firmware upgrade manual for details. Figure 6- 4 xxii Inspur proprietary and confidential information Copyright Inspur Electronic Information Industry Co., Ltd.
  • Page 24: Inspection Guide

    Warning: Please pay attention to prevent the danger of electric shock and do not open this device! Suggest high temperature surface. Warning: Be careful of scalding. Please wait for the device to cool before contacting it! xxiii Inspur proprietary and confidential information Copyright Inspur Electronic Information Industry Co., Ltd.
  • Page 25: Environmental Inspection Of Computer Room

    3、 Do not use too much force when plugging or unplugging cables. 4、 Plug and unplug cables through the connection ports as much as possible. xxiv Inspur proprietary and confidential information Copyright Inspur Electronic Information Industry Co., Ltd.
  • Page 26: Server Patrol

    BMC of the patrol machine need to be obtained in advance. 6.2.2 Inspect indicator The front and rear panels of Inspur Server provide UID button/indicator, system fault indicator, network port indicator, power status indicator, fan indicator, etc. The status of the current server is preliminarily diagnosed by observing the status of the indicator.
  • Page 27: Check Health Status Through Bmc

    The status of other sensors such as hard disk, network, CPU and power supply can also be viewed in this interface. Figure 7- 1 Figure 7- 2 xxvi Inspur proprietary and confidential information Copyright Inspur Electronic Information Industry Co., Ltd.
  • Page 28: Inspection Report

     The software and hardware maintenance after the equipment failure is  found (if the failure cannot be solved, call the Inspur service hotline for repair); Firmware Check the firmware version of the device. If it is found that the firmware ...
  • Page 29: Common Operation

    For example, as shown in Figure 8-1. Click Configuration Query and enter the serial number to view the machine configuration. Figure 8- 1 Figure 8- 2 xxviii Inspur proprietary and confidential information Copyright Inspur Electronic Information Industry Co., Ltd.
  • Page 30: Management Port/Multiplexing Port Ip

    You can check the current IP of the management port by restarting self-checking or entering BIOS. BIOS check BMC's IP address interface as shown in Figure 8-3. If the server cannot be restarted, you can call Inspur No Hotline for support. Figure 8- 3 2.
  • Page 31: Bmc Login

    Figure 7-5 Introduction to BMC management interface The introduction of BMC can refer to the user manual, which can be downloaded in official website. Official website:https://en.inspur.com/ Inspur proprietary and confidential information Copyright Inspur Electronic Information Industry Co., Ltd.
  • Page 32: Component Maintenance

    Raid card and some network cards need corresponding blocking pieces. xxxi Inspur proprietary and confidential information Copyright Inspur Electronic Information Industry Co., Ltd.
  • Page 33: Gold Finger Type

    The board has PCIE interface and non-PCIE interface. For example, fig. 9.4 is a transfer card that is not a PCIE interface, while both card interfaces shown in fig. 9.1 are PCIE interfaces Figure 9- 4 xxxii Inspur proprietary and confidential information Copyright Inspur Electronic Information Industry Co., Ltd.
  • Page 34: Installation Rules

    X16 card slot on the right side and X16 card slot on the left side. Figure 9- 5 CPU maintenance Maintenance steps: Step 1: Match the Clip triangle logo with the corner logo on the CPU, and xxxiii Inspur proprietary and confidential information Copyright Inspur Electronic Information Industry Co., Ltd.
  • Page 35: Memory Maintenance

    (b) For a single CPU, the internal memory is in the order of silk printing: CPU0_C0D0, CPU0_C1D0, CPU0_ C2D0, CPU0_C3D0, CPU0_C4D0, CPU 0 _ C5D0; CPU0_C0D1、CPU0_C1D1…… Figure 9- 6 xxxiv Inspur proprietary and confidential information Copyright Inspur Electronic Information Industry Co., Ltd.
  • Page 36: Hard Disk Maintenance

    A. installation priority of different types of hard disks: SSD->SAS->SATA. B. priority order of hard disk installation for the same model xxxv Inspur proprietary and confidential information Copyright Inspur Electronic Information Industry Co., Ltd.
  • Page 37: Hard Disk Bit Order

    NVME1 NVME2 NVME3 2), 3.5*4 backplane 2: YZBB-00760-101 backplane _ inspur _ 5180 M5 _ 3.5 * 4 _ 3 * SAS+1 * nvme This backplane supports up to 1 NVME hard disk A, only NVME hard disk or ordinary hard disk (SAS/SATA/SSD):...
  • Page 38 NVME7 NVME3 , 2.5*10 Backplane III: YZBB-00872-101 Backplane _ INSPUR _ 5180 M5 _ 2.5x10 _ 4 NVME _ 6AS/SATA The Backplane supports up to 4 NVME Hard Drives, which is required when the number of NVME Hard Drives is less than 5.
  • Page 39: Hard Disk Backplane

    3 screws; B due to structural problems, the cables (SAS cable, power cable, I2C cable) must be inserted into the socket corresponding to the backplane before placing the xxxviii Inspur proprietary and confidential information Copyright Inspur Electronic Information Industry Co., Ltd.
  • Page 40 ×10 model The 2.5x10 model uses a 2.5x10 backplane, with an optional rear 2.5x2 backplane. xxxix Inspur proprietary and confidential information Copyright Inspur Electronic Information Industry Co., Ltd.
  • Page 41 A align the back plate with the fixing screw hole of the rear hard disk cage and fix it with two screws. B, fix the rear hard disk cage into the chassis and fix it with screws. Inspur proprietary and confidential information Copyright Inspur Electronic Information Industry Co., Ltd.
  • Page 42: Power Supply Maintenance

    NF5180M5 Operation and Maintenance Guide NF5180M5 can be equipped with two power supplies, and the power supply sequence is shown in the following figure. priority PUS0>PUS1. pay attention to the buckle during operation, and be careful during disassembly or installation, and pull and insert at a constant speed.
  • Page 43: Appendix: Environmental Protection Statement

    ○ ○ ○ card Connecting × ○ ○ ○ ○ ○ cards Data cable × ○ ○ ○ ○ ○ Keyboard × ○ ○ ○ ○ ○ xlii Inspur proprietary and confidential information Copyright Inspur Electronic Information Industry Co., Ltd.
  • Page 44 GB/T 26572. 4. The above components are possible configuration components in the product. Please refer to the configuration label for actual product configuration. xliii Inspur proprietary and confidential information Copyright Inspur Electronic Information Industry Co., Ltd.
  • Page 45: Supporting Documents

    NF5180M5 Operation and Maintenance Guide Supporting documents Serial number File name Tide Information Overseas official website xliv Inspur proprietary and confidential information Copyright Inspur Electronic Information Industry Co., Ltd.