TABLE OF CONTENTS QUICK START .......................... 3 ABOUT POWERKIT: A Plug-and-Pay Battery Analyzer ............. 3 FEATURES ..........................3 PACKAGE CONTENTS ......................3 INSTALLATION ......................... 4 INSTALLING THE POWERKIT ....................4 INSTALLING THE TEMPERATURE SENSOR ..............4 USER GUIDE..........................4 CHANGING SETTINGS ......................6 SUPPORT ..........................
QUICK START ABOUT POWERKIT: A Plug-and-Pay Battery Analyzer A powerful tool designed specifically for OEMs and dealers to identify and troubleshoot battery problems for their electric equipment fleets. Avoid common battery issues and ensure optimal performance by proactively measuring voltage, current, AMP hours and temperature.
Step 1: Plug connector labeled ‘To Battery’ on the PowerKit, to corresponding connector on equipment leading to the equipment’s battery. Step 2: Plug connector labeled ‘To Lift’ on the PowerKit, to corresponding connector leading to the lift. INSTALLING THE TEMPERATURE SENSOR PowerKit comes with a temperature sensor that gets inserted in a battery cell.
USER GUIDE The PowerKit is essentially a CellTrac with added ease of installation and thus the user interactions remain the same. The CellTrac LEDs indicate current state of the CellTrac. The following table summarizes their function: LED Function Color Rate...
Over Voltage = max charge voltage per cell multiplied by the # of cells. b. Low Voltage = min charge voltage per cell multiplied by the # of cells. Step 5: Select the “Charging Profile” tab. POWERKIT Installation and User Guide...
Page 7
AH to full charge = .8 x battery capacity (AH) Step 7: Change AH to Equalization by: a. AH to equalization = 4 x battery capacity (AH) Step 8: Select ‘Save’ at bottom of page. POWERKIT Installation and User Guide...