Advertisement

Quick Links

VFE-M Manual
Page
1
of
12
Rev. 1.0 12/20

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VFE-M and is the answer not in the manual?

Questions and answers

Summary of Contents for VaporFlame VFE-M

  • Page 1 VFE-M Manual Page Rev. 1.0 12/20...
  • Page 2: Table Of Contents

    3. Meet The VFE-M “Moe”! VFE-M Main Features Product Description 4. Setup Set the VFE-M in a “Lid-up” Orientation. (FIG. 1) Fill The Water Tank with Clean Potable Water. (FIG. 2) Power the Engine (FIG. 3) Switch On The Air Compressor. (FIG 4)
  • Page 3: Getting Started

    If a fixture must be returned to the factory, it is important that it is sent in the original packing. The VFE-M is known internally as MOE, and we refer to the VFE-M as “MOE” or “the engine” in this manual.
  • Page 4 VaporFlame Inc. assumes no responsibility or liability for any errors or omissions that may appear in this user manual. VaporFlame Inc. reserves the right to update the existing document or to create a new document to correct any errors or omissions at any time.
  • Page 5: Safety Instructions

    • The Engine MUST be in a ‘lid up” orientation for running. • Use The Engine for only one type of VaporFlame fixture at a time. (Each fixture requires a different air pressure and The Engine can only be set on a one air pressure at a time.
  • Page 6 airflow. Closing or blocking the cable door may cause The Engine to overheat. • ALWAYS drain the water tank prior to travel or storage. • DO NOT block fans on exterior of the case. Doing so may cause The Engine to overheat.
  • Page 7: Meet The Vfe-M "Moe

    • Air/Water Blow Off Valve Product Description The VFE-M is an air compressor and water pump set built into a mobile road case that serves as an "Engine" to the VaporFlame System.   This case houses an air compressor, water pump, water tank and hoses to deliver enough air and water for several VaporFlame units.
  • Page 8: Setup

    4. Setup Set the VFE-M in a “Lid-up” Orientation. (FIG. 1) The VFE-M Engine features a “tilt-and-roll” handle for ease of transport, but must be set in a “lid-up” orientation when run. 1. The Tilt-and-Roll handle may be retracted into the case by releasing the red locking latch and gently pushing the handle into the case.
  • Page 9: Switch On The Air Compressor. (Fig 4)

    3. Connect the Air/Water hose to the VaporFlame effect units. Set up your VaporFlame Effect unit 1. Power up the VaporFlame effect and lighting fixture per their manuals. Drain remaining water from the unit before storage. 1. Disconnect the VaporFlame effects units from the Air/Water hoses.
  • Page 10: A Few More Things

    Any clean potable water can be used in The Engine. In short, if you can drink it, so can the VFE-M. Debris in the water line can clog and damage the VaporFlame units. We have installed a filter for debris on the water supply line.
  • Page 11: Warranty

    If VaporFlame determines the fixture is under warranty, then VaporFlame will correct the issue and ship back to owner at VaporFlame’s expense. If VaporFlame determines the fixture is not under warranty, VaporFlame will ship the fixture back to the owner at the owners expense.
  • Page 12: Tips And Tricks

    I crossed the streams and now 1. Don’t cross the streams!! the VaporFlame effect won’t 2. Sending water into the air hose of a VaporFlame effect will work damage the internal air valve. You can try letting the unit dry out for a few hours.

Table of Contents