Insert the batteries
1
4
MEASUREMENT
Remove protective cap from the probe
off
Lock/Unlock Data!
unlock
C. Backlight ON/OFF
F. Store Data
off
D. Store Data
1. In lock mode:
2s
2. In measurement mode:
3. When the storage is full, it will overwrite the oldest data.
CON CALIBRATION
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Characters in
G. System Setup
Menu selection:
• Re-Calibrate according to individual recommendations! Rinse the electrode
with distilled water after each measurement.
• If temperature is out of range, "ERR" will appear. Meter automatically returns to Measurement Mode.
• If the default reading is more than 30% out of standard buffer range, "ERR" will appear.
2s
E1. Auto Mode
Remove protective cap from the probe.
Power ON (see A)
(7.00
or 6.86)
Auto-recognition for
Immerse the probe
(31-12 24
or
12-31
12ampm)
into
calibration
solution (1413 µS).
To enter:
Immerse the probe into
calibration solution
____________________________________________________________________________________________
(12.88 mS).
Note: Icons/Characters in
RED
meaning "BLINK"
: Hit once /
: Press and hold /
E2. Manual Mode
Remove protective cap from the probe.
Power ON (see A)
: Limited to 200 ~ 2000 µS; : limited to 2.00 ~ 20.00 mS
Immerse the probe
into
calibration
solution.
Adjustment
To increase (+):
to store
Immerse the probe into
calibration solution.
Adjustment:
to store
2
5
on
off
lock
unlock
on
off
2s
(or
RED
represent
"Flashing
(latest memory#)
(dd-mm-yy/24hr or mm-dd-yy/12hr)
: 1413 µS and
: 12.88 mS
.....
: Release
+
To decrease (-):
wait
+
to increase (+);
To decrease (-):
wait
3
+
+
-
-
-
-
+
+
6
Press for
3 seconds
Press
Automatically turns off after 8 minutes of
inactivity.
Possible slight delay after pressing
before freeze of the data (!).
After 3 sec. the file no. temporarily appears
on the display, e.g. 01.
Once the storage has reached max. capacity,
the data will overwrite the oldest files.
2s
)
symbols".
(°C or °F)
wait
3
wait
Press and
hold

Advertisement

loading

Summary of Contents for ORBECO SD 70

  • Page 1 Insert the batteries ∞ MEASUREMENT Press for Remove protective cap from the probe Press and 3 seconds Press hold Automatically turns off after 8 minutes of inactivity. Lock/Unlock Data! Possible slight delay after pressing before freeze of the data (!). unlock lock unlock...
  • Page 2 Exit 24 hour am/pm clock 12 hour clock SD70 Conductivity Specification/Features Content 1 Conductivity Meter SD 70 in a robust plastic case 2 Batteries 1 Instruction Manual Order Code: L194802 Accessories 4000-06 Battery CR 2032 (2 Batteries required) L194822 Replacement electrode L384801 Beaker, 100 ml VI.