Installation

INSTALLING THE APPLIANCE
1. Remove all packaging and check carefully for any
signs of damage.
2. If fitting the microwave oven above a conventional
oven (position A) then use the mylar sheet provided.
a. Cut the Mylar sheet to fit the internal width of
the unit.
b. Peel back the protective cover on the tape and fix
to the rear of the shelf
so that it covers
the service
gap. (See
diagram).
SAFE USE OF THE APPLIANCE
If fitting the microwave in position B or C:
• The cupboard must be a minimum of
500mm (E) above the worktop & must not
be installed directly above a hob.
• This appliance has been tested and
approved for use near domestic gas,
electric and induction hobs only.
• Sufficient space between hob and
microwave should be allowed to prevent
overheating of microwave oven,
surrounding cupboard and accessories.
• Do not operate the hob without pans
when the microwave oven is operating.
• Care should be taken when attending to
the microwave oven while the hob is on.
Mylar sheet
Conventional
oven
Conventional
POSITION
Measurements in (mm)
3. Fit the appliance into the kitchen cupboard slowly,
and without force, until the front frame of the oven
seals against the front opening of the cupboard.
4. Ensure the appliance is
stable and not leaning.
Ensure that a 5mm gap is
kept between the cupboard
door above and the top of
the frame (see diagram).
5. Fix the oven in position with the
screws provided.
The fixing points are located on
the top and bottom corners of
the oven (see diagram, item 10,
on page 5).
6. It is important to ensure that the installation of this
product conforms to the instructions in this
operation manual and the hob or conventional oven
manufacturer's installation instructions.
Chimney
Position A
Position B
oven
NICHE SIZE
W
D
A
560 x 550 x 360
B + C
460 x 300 x 360
560 x 300 x 360
D
460 x 500 x 360
560 x 500 x 360
Position C
E
CHIMNEY
Gap Between
H
(min)
Cupboard & Ceiling
50
18
18
40
40
5 mm
Chimney
Position D
D
50
50
50
50
50
43