PT-FW300NTU / PT-FW300NTE / PT-FW300NTEA / PT-FW300U / PT-FW300E / PT-FW300EA / PT-F300NTU / PT-F300NTE / PT-F300NTEA / PT-F300U / PT-F300E / PT-F300EA
7.2.2.2.
Method of Command Transmission
Transmits command by the following format.
Transmission Data
Reception Data
Error Response
Example 1: Query Power "QPW"
1. Connects to the projector.
IP = 192.168.0.8, Port number = 1024
2. Receives a response.
Response = "NTCONTROL 0" + (CR)
3. Transmits the command.
Transmission data = "00QPW" + (CR)
4. Receives a response.
Reception data = "00000" + (CR)
5. Disconnects the connection with the projector.
Example 2: Query FILTER INFORMATION - RUNTIME "QFI:0"
1. Connects to the projector.
IP = 192.168.0.8, Port number = 1024
2. Receives a response.
Response = "NTCONTROL 0" + (CR)
3. Transmits the command.
Transmission data = "00QFI:0" + (CR)
4. Receives a response.
Reception data = "000142" + (CR)
5. Disconnects the connection with the projector.
7.3.

Control commands

All manuals and user guides at all-guides.com
Header
´0´ 0x30
´0´ 0x30
(ASCII character string)
1 byte
1 byte
Header
´0´ 0x30
´0´ 0x30
(ASCII character string)
1 byte
1 byte
Error Message
"ERR1"
Command format error
"ERR2"
Out of parameter
"ERR3"
Busy or unavailable time
"ERR4"
Timeout or unavailable time
"ERR5"
Data length error
"ERRA"
Invalid password
4 bytes
Data section
End character
Control command
(CR) 0x0d
Undefined length
1 byte
Data section
End character
Control command
(CR) 0x0d
Undefined length
1 byte
End character
(CR) 0x0d
(CR) 0x0d
(CR) 0x0d
(CR) 0x0d
(CR) 0x0d
(CR) 0x0d
1 byte
13

Advertisement

Table of Contents
loading

Table of Contents