SyxthSense FCU2001 Engineering Manual

SyxthSense FCU2001 Engineering Manual

Digital interface

Advertisement

Quick Links

FCU2001 and SY100 Digital Interface
Engineering Guide
Copyright © 2004 Syxthsense Ltd
All rights reserved.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FCU2001 and is the answer not in the manual?

Questions and answers

Summary of Contents for SyxthSense FCU2001

  • Page 1 FCU2001 and SY100 Digital Interface Engineering Guide Copyright © 2004 Syxthsense Ltd All rights reserved.
  • Page 2 SyxthSense Limited. SyxthSense Limited has prepared this document in good faith based on information made available to it by third party contributors. SyxthSense reserves the right to make amendments and to correct any errors that are identified herein without notice.
  • Page 3: Table Of Contents

    ..........................12 INDOW ONTACT P-9 B ..........................12 ATHROOM LARM CHAPTER 4 COMMISSIONING AND MAINTENANCE CHECKS 13 Copyright © 2004 SyxthSense Ltd. Online Store: www.syxthsense.com Enquiries: T: 0870 20 80 100 F: 0870 20 80 200 FCU2001 and SY100 Engineering Guide...
  • Page 4: Introduction

    These are available from SyxthSense ltd. Copyright © 2004 SyxthSense Ltd. Online Store: www.syxthsense.com Enquiries: T: 0870 20 80 100 F: 0870 20 80 200 FCU2001 and SY100 Engineering Guide...
  • Page 5: Urning The Controller On / Off

    When the dead zone nearest to the selected set point is reached, the fan will be Copyright © 2004 SyxthSense Ltd. Online Store: www.syxthsense.com Enquiries: T: 0870 20 80 100 F: 0870 20 80 200 FCU2001 and SY100 Engineering Guide...
  • Page 6: Ontrol Of The Valves

    Copyright © 2004 SyxthSense Ltd. Online Store: www.syxthsense.com Enquiries: T: 0870 20 80 100 F: 0870 20 80 200 FCU2001 and SY100 Engineering Guide...
  • Page 7: Alarms

    Copyright © 2004 SyxthSense Ltd. Online Store: www.syxthsense.com Enquiries: T: 0870 20 80 100 F: 0870 20 80 200 FCU2001 and SY100 Engineering Guide...
  • Page 8: Alarm

    This function could also be used for a maid call or do not enter status in different applications Copyright © 2004 SyxthSense Ltd. Online Store: www.syxthsense.com Enquiries: T: 0870 20 80 100 F: 0870 20 80 200 FCU2001 and SY100 Engineering Guide...
  • Page 9: Programming Of The Fcu2001

    Contact bathroom alarm No .not used P0.- N=2 pipe ; S=4 pipe P1.- N=P7 ; S= Entrance Copyright © 2004 SyxthSense Ltd. Online Store: www.syxthsense.com Enquiries: T: 0870 20 80 100 F: 0870 20 80 200 FCU2001 and SY100 Engineering Guide...
  • Page 10: Ontroller Address

    Copyright © 2004 SyxthSense Ltd. Online Store: www.syxthsense.com Enquiries: T: 0870 20 80 100 F: 0870 20 80 200 FCU2001 and SY100 Engineering Guide...
  • Page 11: Imted Or Free Set Point Point

    Value N sets the operating conditions to be Summer. It is this value by default. Value S defines the operating conditions to be Winter. Copyright © 2004 SyxthSense Ltd. Online Store: www.syxthsense.com Enquiries: T: 0870 20 80 100 F: 0870 20 80 200 FCU2001 and SY100 Engineering Guide...
  • Page 12: Indow Contact

    Value N defines that we do not arrange this contact. Annulling the functions associated the same one. It is the value by defect Value S considers that if we arrange it. Copyright © 2004 SyxthSense Ltd. Online Store: www.syxthsense.com Enquiries: T: 0870 20 80 100 F: 0870 20 80 200 FCU2001 and SY100 Engineering Guide...
  • Page 13: Commissioning And Maintenance Checks

    O5. It is assigned to the third fan speed leave the test menu by pressing the fan button. Copyright © 2004 SyxthSense Ltd. Online Store: www.syxthsense.com Enquiries: T: 0870 20 80 100 F: 0870 20 80 200 FCU2001 and SY100 Engineering Guide...
  • Page 14 SyxthSense Limited Gibbs House Kennel Ride Ascot SL5 7NT United Kingdom Enquiries: T: 0870 20 80 100 F: 0870 20 80 200 Online store: www.syxthsense.com Copyright © 2004 SyxthSense Limited. All rights reserved.

This manual is also suitable for:

Sy100

Table of Contents